X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-069-20140

Well Details

Well ID: 34-069-20140
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2006-10-13
Unconventional:
Horizontal:
Producing: No
Violations: 3
Latitude: 41.3223137371
Longitude: -83.9329567027

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1969491983 2013-01-31 At the time of the inspection the well was shut. There was 0 psi on the annulus gauge and no gauges on the production lines. There were no signs of any leaks. The corrective action from the Compliance Notice issued in 2011 has not been completed. The inspection was done at the request of Eric Vendel from The Ohio Division of Oil and Gas.
1160686033 2006-10-12 Drill rig being set up on site. Pit for drilling fluid has been excavated and pit is lined with plastic. Spoke to tool pusher on site. Hope to start drilling on Friday.
1161777739 2006-10-16 Operator cemented 9 5/8 inch surface casing on 10/14/06. Spoke to operator Dave Buckholder about cement job and received copy of cement ticket. Cement was circulated to surface and no problems encountered with cementing. Pit for drilling fluid ripped during drilling. Well was drilled with fluid rotary rig. Drilling mud was contained in tank on site. Shaker removed drill cuttings from mud. Only fresh water was encountered and discharged into pit. The ground was clay and no tiles were noted in the field. Discussed pit liner with Dave. No salt water may be discharged into pit unless the pit liner is replaced.
1164145881 2006-11-14 Checked well site. Pump jack is on well and well is in production. Pit has not yet been backfilled and there is water in the pit. An ID sign needs to be posted at the well. Final restoration needs to be completed. Spoke to local operator Tony who indicated that the well yet needs to be serviced and water in pit may be needed. ID sign has been ordered. Water will be pumped from pit, pit backfilled and final restoration completed.
1175192122 2007-03-29 Well was drilled in October 2006 and is in production. ORC 1509.072 requires that pit used during drilling must be backfilled within 5 months. Further area around well not used for production must be properly graded, resoiled and planted within 9 months of drilling. Pit must be backfilled and graded immediately unless a written request and reason to leave pit open are submitted. Resoiling, grading and seeding must be completed by June. If access road is to remain permanent, a signed, written request must be obtained from the landowner. Also there is no ID at the well. ID sign must be posted immediately.
1184705593 2007-07-17 Pit on site has been backfilled. Dirt for pit is above ground elevation to allow for settling. Some of the other area around the well has been graded. Stone drive and stone area around well remain. Landowner consent needed if stone is to remain. Pumpjack on well. No ID sign posted. ID must be posted.
124359249 2011-08-03 Well has pumping unit on well but no motor. No production records since 2006. Well site in poor shape with stone, plastic pipe and two 55 gal steel drums left. Small oil stain from one drum. Oil between conductor and 12" plastic cellar. Small amount of gas leaking from casing head around tubing. No tank battery present. I.D. present but falling off well. NONE_
124359249 2011-08-03 Well has pumping unit on well but no motor. No production records since 2006. Well site in poor shape with stone, plastic pipe and two 55 gal steel drums left. Small oil stain from one drum. Oil between conductor and 12" plastic cellar. Small amount of gas leaking from casing head around tubing. No tank battery present. I.D. present but falling off well. NONE9
124359249 2011-08-03 Well has pumping unit on well but no motor. No production records since 2006. Well site in poor shape with stone, plastic pipe and two 55 gal steel drums left. Small oil stain from one drum. Oil between conductor and 12" plastic cellar. Small amount of gas leaking from casing head around tubing. No tank battery present. I.D. present but falling off well. NONEC
1808849200 2006-10-17 Operator cemented 7 inch casing late Monday night. Spoke to operator Dave Buckholder about cement job and received copy of cement ticket. Cement was circulated to surface and no problems were encountered during cementing. Cement dropped 20-30 feet from surface by morning. Cement will be added from surface to top off annular space. Salt water used for drilling was contained in tank on site. Drill cuttings were removed with shaker. No brine was encountered during drilling and no salt water was discharged into pit.
779029659 2012-01-04 No change from last inspection. NOV's from last inspection on 8/5/2011 still need resolved.
884294477 2008-08-12 Sign posted at well. Well not in production at this time. Pit backfilled and area disced. Preliminary restoration acceptable.