34-155-20769

Well Details

Well ID: 34-155-20769
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1979-07-06
Unconventional:
Horizontal:
Producing: No
Violations: 7
Latitude: 41.3760838566
Longitude: -80.9989408472

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1151238845 2005-02-03 Case# 04-003 , Keneth Klouda . Well is still idle . Conf. With company , they advised me they will put well into production . NONE
-1359975988 2004-05-25 Case# 04-003 , Kenneth Klouda . No activity to produce or plug well . NONE
-1645121779 2012-07-20 On 7/20/2012, I completed a follow-up inspection. The well tender installed the proper identification. Inspection was passed.
-444342848 2004-04-07 Case# 04-003 , Kenneth Klouda . No activity to produce or plug well . NONE
-643042424 2011-08-22 There were no violations found at the time of my inspection.
-840951597 2005-07-14 Case# 04-003 , Kenneth Klouda . Well is still idle at this time . Company advised me they are still trying to get accsess to gas sales line . NONE
1341923298 2012-07-10 On 7/10/2012, I conducted a production well inspection status check. This well shares a tank battery and lease road with permit number 34-055-2-0286-00-00. My inspection found the pumping unit has been removed and the well was shut in. The tank battery contained one 210 barrel oil storage tank with no identification posted, one 30 barrel brine tank, and two separators. I called Bocor, at 330-494-1221, and I was told the well is producing and has become a swab well. I asked for the well tender to install the proper identification. I will perform a follow-up inspection by 7/20/2012.
1381409692 2013-10-09 I responded to an inspection request from the landowner for a possible oil spill at the tank battery. My inspection found crude oil around the two separators and next to the 30 barrel brine tank. The spill was completely contained inside the dike. According to the landowner; he claimed the valve on the load line at the brine tank was open, which he closed after discovering the spill. The spill appears to have originated at the brine tank. I found the 2" plug for the load line valve was lying on top of the brine tank and a 4" diameter depression on the ground from the oil spilling out. I immediately called the well tender, Jim Palmier, at 330-705-3011 and Todd Sutko, Bocor field supervisor, at 330-506-2531. I instructed both gentlemen to start clean-up operation immediately. Todd stated Bocor would start mobilizing equipment and begin cleaning up the oil spill first thing the next day (10/10/13). I took photos of the oil spill.
1658695050 2004-10-20 Case# 04-003 , Kenneth Klouda . Well is still idle . NONE
302740170 2013-10-11 My inspection found all of the impacted soil piled up at the south end of the tank battery and ready to be removed once the dump truck arrives. Both of the separators were disconnected and moved to remove any impacted soil. Bocor had peat sorb spread through the affected area. Todd Sutko stated new gravel would be spread.
443935169 2005-09-08 Case# 04-003 , well in production , RESOLVED . NONE
725150317 2013-10-10
959761281 2004-02-12 Case#04-003 , Kenneth Klouda . Tank battery is in tact . Well showed 4.5 casing with valve which is shut-in . Well is disconnected from flow line . Well is idle . NONE