Well Details

Well ID: 34-083-23553
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1984-10-08
Unconventional:
Horizontal:
Producing: No
Violations: 1
Latitude: 40.4657099105
Longitude: -82.2544959425

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1768151535 2006-10-05 On site by request of Dave Crow. Follow up on report of violation. No identification posted at the well head or the storage site. Does not appear to have been produce for some time. Well and pumping unit are over grown w/brush and trees. Pulies on pumping unit motor and gear box are rusty indicating none use.

Storage site shows signs of brine spills around tank. Tank appears to be leaking around the bottom. I would recomend not using the tank untill repaired, or remove it and install a good tank. Called the phone number that is in RBDMS not a working number.

-478703959 2010-01-20 Follow up on NOV issued by Rocky King. No identification posted at this time.
-869011398 2012-01-19 A Final Restoration inspection was requested by well owner, Mr. Bill Stachler (sp?). During the inspection, it was noted that restoration does not meet ORC 1509.072. Oilfield debris consisting of plastic and steel line, electric line and pole, joints of steel casing tanks may have sat on, and section of load line. Mr. Stachler was present for the inspection and agreed to remove all debris.
1125594585 2005-09-01 Owner needs to properly identify the well tanks with Name, Permit number, Emergency phone # contact etc.
1287i373 2001-09-28 no id , well in production 9-9-05(A)10
1330487458 2012-02-24 During my inspection I completed a final restoration status check and found leftover oil field debris at the location. It consisted of three pieces of 4.5" casing, a 55 gallon plastic drum of crude oil laying on its side, three electric poles and a strand of wire, a 3" metal pipe near the tank battery, and a 2" metal line buried beneath the lease road. The tank battery also needs to be addressed as there is gravel where the tanks sat and the dike needs removed and the area graded and seeded. Final restoration not finished.
1334929278 2012-04-16 During my inspection I completed a final restoration status check. All production equipment has been removed. Final restoration is complete.
1379520701 2013-09-18 This CA has Been resolved
PL14606 Preliminary Restoration done information from Data Point