34-083-24412

Well Details

Well ID: 34-083-24412
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2008-10-03
Unconventional:
Horizontal:
Producing: No
Violations: 3
Latitude: 40.2888180843
Longitude: -82.3060185192

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1043301093 2012-01-31 Site inspection with Jeff Fry and Will Ziegler, injection pump is leaking into the dike, operator will be advised to repair,
-120259573 2013-06-26 Well is and injection well no violations during inspection.
-1265347316 2014-05-30 This date received a phone call from John Niceswanger saying all of Dow Cameron's fleet has been equipped or stenciled with their phone number .
-1276858044 2012-03-30 An inspection of this saltwater injection well revealed pressure equalization. Vacuum was observed on both the injection and annular sides of the well. Note: The injection pump was not running at time of inspection. At the conclusion of inspection, I notified the well owner, Mr. Phil Moran, of this deficiency by telephone. Mr. Moran agreed to resolve, as this well had exhibited the same conditions back in February. (Note: While pumping since February, pressure would be observed on the injection side and Mr. Moran would add fluid to annular space resulting in no vacuum.) Absorbent pads have been placed around the pump inside the pump house. 9-3-07(E)
-1276858044 2012-03-30 An inspection of this saltwater injection well revealed pressure equalization. Vacuum was observed on both the injection and annular sides of the well. Note: The injection pump was not running at time of inspection. At the conclusion of inspection, I notified the well owner, Mr. Phil Moran, of this deficiency by telephone. Mr. Moran agreed to resolve, as this well had exhibited the same conditions back in February. (Note: While pumping since February, pressure would be observed on the injection side and Mr. Moran would add fluid to annular space resulting in no vacuum.) Absorbent pads have been placed around the pump inside the pump house. 9-3-07(H)
-1373965125 2014-08-27 Inspect facility. Pump in operation during inspection. Collect Brine sample TSB064 for chemical analysis.
-1582093509 2014-04-10 Inspect well for integrity and pressure. The annulus valve is open.
-1679013550 2014-08-21 Inspect Dow Cameron truck UIC#343; Tractor DC-28; Trailer TK-4 at well head.
-1710360862 2012-06-27 Today I inspected the tank battery for the injection well accompanied by Jeff Fry. During inspection a brine truck with Diversified Resources was unloading a tank of water. UIC number was displayed and visible. The UIC number was 25-424. No violations during inspection.
-1810808874 2013-09-05 Inspect well for integrity and pressure.
-1888934474 2009-09-30 Jeff Fry and I inspected the well location at the request of Tom Tomastik. We met with the landowner and well owner Phil Moran. He explained his intentions about converting his Clinton well into a salt water injection well. We discussed the area to be used for the unloading pad, storage tanks, dike construction, and the plug back procedures for this operation. Also, we took GPS coordinates for the nearest water well, which is on Phil Morans property.
-1978882999 2011-09-26 An inspection revealed no violations.
-2130956941 2012-02-06 An inspection revealed that well contained vacuum on both injection and annulus sides of well. Note: Pump not running at time of inspection. The annulus valve was opened for approx 10 seconds with constant vacuum. After checking the injection side of well and observing vacuum, the annulus valve was again opened and verified presence of vacuum. At 9:37 am, I left Mr. Phil Moran a voicemail message. Mr. Moran would check well later this evening while pump was running and observed vacuum on annulus. However, states it eventually blew down. Further stating 200 psi on injection and filled fill annulus with approx 15 gal of water. Agreed to meet at well location tomorrow for further review.
-273875286 2010-11-10 The inspection showed that there was 85psi on the injection and 0psi on the annular space. There was proper identification posted. There were no violations noted this date.
-294523782 2012-02-07 Returned to the well location today and met with Mr. Phil Moran, well owner, to check the status of this well. The pump was running at time of inspection. 170 psi was observed on the injection side of well and now 21 psi on annulus. Mr. Moran agreed to closely monitor well status.
-298345922 2012-12-20 I inspected this injection well and facility today accompanied by UIC Inspector Tom Benko. No trucks unloading during visit. The pump was not running. No violations were observed.
-389071904 2012-04-12 I accompanied Brent Bear during this inspection. Phil Moran was running new tubing and packer in the well.
-390535948 2010-07-01 I witnessed drilling operations today. B&J Drilling are drilling at a depth of 518 feet. All fluids are being contained within a properly lined pit. There are no violations noted this date.
-885350827 2009-11-06 I witnessed the construction of the dike, the setting of tanks, and pump house.
-924745369 2013-01-29 I inspected the tank battery facility at this salt water injection well location today. There were no trucks during inspection. The pump was not running. No violations.
1027772381 2014-01-09 Inspect well for integrity and pressure. Pump in operation during inspection.
1122011437 2013-05-13 Inspect tank facility. No truck activity. Operator indicated it has been slow the last few weeks.
1135124045 2009-11-12 I inspected the construction of the tank battery and dike location today. The pump house building has been built and located inside the dike along with three 300 barrel tanks. A concrete unloading pad has been constructed with a curb around the outside. There is a drain the pad that leads to the an underground tank. The lead line to the well has been placed on top of the ground but has not yet been pressure tested.
1197986938 2014-04-22 Inspect well. Well in production. Pump running during inspection.
1223143511 2008-10-04 Witnessed cementing of surface casing. Good returns.
1256225688 2009-10-21 I witnessed the bottom hole plug today. There was 25 sacks of cement used to plug the Clinton by the bulhead method for 300 feet of fill up. The well is being plugged back to be used as an underground injection well. The pressure test is set up for 10-23-09. I also witnessed the construction of the dike area and the installation of the 30 mil liner and sand. Construction will continue tomorrow and into next week.
1256742774 2009-10-22 Phil Moran is completing the construction of the dike. Four inches of sand was placed underneath and on top of a 30 mil liner. Around the dike walls an additional liner was used. This second liner was placed on top of the sand and the 30 mil liner. Gravel screenings was then placed on top of this second liner. The dike measures 40 feet by 60 feet with approximately 40 inch side walls. It will contain three 300 barrel tanks and the pump.
1260808461 2009-12-14 I inspected the tank battery / pump house location of this injection well today. Phil Moran was not on location. The line between the tanks and the well need to be pressure tested. The pump was not running and there was zero pressure on the line. 882 barrels have been pumped. There were no violations noted this date.
1293125901 2010-12-23 Talked to well operator Phil Moran this date. ID is posted.
1322591972 2011-11-29 An inspection revealed no violations at this time. The injection pump was running at time of the inspection. Flowmeter not installed at this time. Note: Rainfall event today.
1362597490 2013-02-25 Inspect Surface facility. Collect brine sample TSB021 from tanks. Water sample is primarily flow back water delivered by Dow Cameron from the Gulph Port Energy, Lyons #1-27H, 3406721088. Measure tank storage dike area; 45 ft by 69 ft by 3.25 ft.; Three 300 bbl tanks.
136584635 2012-04-11 I accompanied Brent Bear during this inspection. Phil Moran was pulling tubing and replacing it with new tubing and packer.
1381313979 2009-10-27 Cemenco used there pump truck to pressure up on this well today in order to get the formation to brake and open up. The well was taking approximately 2 barrels a minute at 750 psi. Phil Moran, the well owner would like to see it do better than that and will treat the well with more acid. Producers came this afternoon and treated the well with 1200 gallons of acid and also pumped pressure on the well. The well then took about 6 barrels a minute with 750 psi.
1387216027 2010-12-22 Well not running. Met owner Phil Moran. Questions on forms. Did not go to well head. Facility appears ok. Needs ID.
1393427423 2014-02-24 Inspect well and tank battery. Pump off during inspection. Collect brine water sample for chemical analysis TSB047.
1397144809 2014-04-10 Inspect Brine Truck Wilsons Water Hauling UIC 25-309.
1402315543 2014-05-29 Stopped at injection well and assisted Inspector Benko, and operator Phil Moran to pressure test injection line from pump house to both injection wells. This permit and permit 4603. While I was at the pump house a red semi tanker belonging to Dow Cameron arrived to unload. UIC 343, driver D. Grubbs. Truck was a red Peterbuilt license PHJ382, with a red trailer license TQA7107. At 10:15am I checked his hauler log. This was his second trip this date from frac tanks at their yard, storage Permit 2014-07 . Both times he had a load of 130 Bbl.. Log was correct but truck failed to have the Dow Cameron's phone number displayed per 1509.223. I informed the driver of violation. He then called their shop and had me talk to John Niceswanger. I informed John of requirements of 1509.223 and he informed me they would correct with decals and notify me when done. NONE..
1408120422 2014-08-07 Inspect facility. There were not any trucks unloading during inspection. Recipes for four trucks were at the facility.
1410261665 2014-09-08 Inspect brine hauler at unloading pad. Sheeler Dozer Service UIC 25366; Log and truck are current. Collected Brine sample Number TSB065 from truck for chemical analytical analysis. The water was from the Sands #1 in Licking county API # 34089234690000.
1490905748 2009-10-23 A pressure test on the bottom hole plug was performed today. A solvent truck was used to pressure up on the well. At 9:25 am the test began with 715 psi on the well. At 9:40 am there was 705 psi on the well. The well passed the pressure test as there was less than 5% loss during the 15 minute test.
1568162415 2011-10-03 Meet Phil moran at site and went over operation of well and site.
1769634894 2014-09-08 Inspect brine truck at unloading pad. Dow Cameron UIC# 25343; Tractor DC28 and Trailer TK4. The Log book and truck are current. The Moran well service pump filters have been plugged up prematurely and casing the pump to shut down. The Dow Cameron Tuck unloaded 130 bbl of sludge type brine water to be disposed at a different facility.
1907153924 2013-06-20 Inspect water truck Berry Well service Truck UIC 25-354 truck #143. Collect water sample from the truck for chemical analysis sample TSB029.
1942572568 2009-12-30 Jeff Fry and I inspected this well location today and performed a pressure test on the pipeline between the tank battery and the injection well. The pressure test passed. The test began with 620 psi at 9:32am and ended at 9:47 with 620 psi. Phil Moran was also on location. Phil still needs to post proper identification and the construction of this injection well facility will be complete.
2035819234 2009-10-26 Jet Wireline Services, Inc. perforated this well today. The well was loaded with acid and then salt water before being perforated. There were a total of 41 shots. They were 2 and 1/8 bi-wire shots. The perforation was from 2365 to 2405.
2126940036 2014-08-21 Inspect well for pressure and integrity. The pump was in operation at the storage facility. The well was shut in during inspection.
2135920832 2010-09-23 Well not operating. Needs ID posted at facility and wellhead. Talked to County Inspector Will Ziegler. He contacted well operator Phil Moran this am on ID and pressure monitoring.
224669197 2013-10-24 Inspect well for integrity and pressure.
265171698 2009-11-05 I witnessed the construction of this dike facility. Three 300 barrel tanks are being placed inside of the dike along with the pump house.
285994434 2012-08-15 I inspected this well today at approximately 11:00 am. There were no trucks unloading during inspection and the pump was running. ID was posted at the tank battery and at the well. No violations observed.
312866163 2014-04-22 LBJ Drilling Co. UIC 103 unload at facility. Truck identification ok.
423129706 2012-04-12 I witnessed the construction and testing activity performed on this saltwater injection well today. Cemenco pumped packer inhibitor through 2 7/8" tubing and circulated to the surface. The well was shut-in and 625 psi was placed on the annulus. The pressure was monitored for the required 15 minutes with an allowance of 5% decline. After 15 minutes, my gauge showed 622 psi with only 3 psi loss. The well passed the required test.
540945870 2014-07-08 Inspect well for integrity and pressure.
673572392 2014-06-16 Inspected Three Dow Cameraon Brine tanker trucks. Collected brine water sample TSB056 for chemical analysis from truck DC26 trailer TK3. Inspected truck DC25 trailer TK7 and truck DC14 trailer TK5. Markings and log were present.
775379107 2012-04-11 An inspection revealed service rig on location to pull 2 3/8" tubing and packer from wellbore, due to pressure equalization. During the retrieval, the top of packer came loose and fell down the hole. Mr. Phil Moran ran his tools in the hole and verified packer was on bottom of well. Witnessed the installation of used 2 7/8" tubing with new Parmaco Packer into the wellbore with Jeff Fry and Brandon Mitchell. Packer inhibitor and pressure test will be conducted tomorrow.
933679790 2012-01-31 I accompanied Jeff Fry and Will Ziegler during this inspection.
979493811 2014-07-08 Inspect Dow Cameron Oil and Gas brine hauling truck UIC 343. Tractor DC28 with Trailer TK4. Log and truck ok.