If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-153-22924 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.1673968958,"lon":-81.6288607516,"icon":""}]} |
County: | |
Municipality: | |
Operator Name: | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 2002-10-28 | |
Unconventional: | |
Horizontal: | |
Producing: No | |
Violations: 2 | |
Latitude: 41.1673968958 | |
Longitude: -81.6288607516 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
-1702371642 | 2003-01-08 | November 18, 2002 - The subject site was inspected for the purpose of determining the distance between the tank battery under construction and a vacant house south of the tank battery. The inspection was prompted by a spacing question posed to me by the Bath Township Zoning office. A roustabout crew was on site at the time of this inspection and assisted in measuring the distance between the house and the nearest stock tank. The measured distance was 83 feet and the crew was informed of the minimum distance requirements, including 100 feet between an occupied dwelling and a stock tank. Mr. Cal Marks with Transcontinental was notified of the problem by phone. Several possible locations were discussed and I reminded him of the minimum spacing requirements before leaving the site. A NOV was not issued since the tank battery was not operational.
December 3, 2002 - I was informed that the tank battery was relocated south of house and that it met all spacing requirements. January 8, 2003 - The site was inspected and I was told by the same roustabout crew that the tanks were 108 feet from the house and 70 feet from the wellhead. The site has been rough graded and the pits have been solidified. The secondary containment dike has been constructed around the tank battery. The well will be turned on in the very near future. No violations at this time. |
||||
-1979277888 | 2004-02-18 | A status check inspection found that the tank battery equipment did not have the required distance between the separators and the tanks. The required distance between separator and tank is ten feet, the actual is less than three feet. Common tank battery with the O'Neill 2-D P/N 2925. | 9-9-05(A)5 | |||
1037154788 | 2002-11-04 | Status check inspection after the drilling was completed. Landogs Rig #1 completed the 1-D well and was being moved 100 feet north to spud the 2-D well. No violations at the 1-D site. The suction pit fluids will be transferred to the 2-D pits once they are lined. | ||||
1079038172 | 2004-03-10 | The two 210 bbl stock tanks have been labeled, one brine and the other stock with the stock tank being over 10 feet from the nearest separator. The violation is corrected. | 9-9-05(A)5 | |||
1740218041 | 2002-11-18 | The drilling rig has moved off and the pits are being pumped out and solidified. |