34-105-23319

Well Details

Well ID: 34-105-23319
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1984-12-01
Unconventional:
Horizontal:
Producing: No
Violations: 13
Latitude: 39.0627669172
Longitude: -82.0561212473

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1019317996 2005-05-06 Pump was off, while the readings were taken. 9-3-07(G)
-1034071380 2005-08-04
-104043520 2004-10-08 There were no violations at the time of inspection.
-1149894788 2006-10-17 No violations. Accompanied by Jon Scott.
-1158475857 2007-07-17 There were no violations at the time.
-1317774207 2010-11-19 Dike has been sealed. Oil barrel has been cleaned up. Injection fittings have been re-plumbed to allow easier access.
-1380435045 2013-07-17 No violations.
-1468081414 2007-02-16 There were no violations at the time of inspection.
-1555745678 2005-07-22 Witnessed the cementing of the long string.
-1713684586 2005-01-13 There were no violations at the time of inspection.
-1713684586164851 2005-01-13 There were no violations at the time of inspection.
-1756462270 2005-07-07
-1831406854 2007-04-12 There were no violations at the time of inspection.
-1965557682 2011-03-25 Witnessed company monthly mini test. Tested annulus to 520 psi for 15 minutes. Pressure dropped to 505 in 15 minutes.
-1974093962 2006-12-18 There were no violations at the time of inspection.
-2090569248 2013-12-02 No violations noted at facility.
-2117748693 2004-02-05 Pressures were measured, while the pump was on. No violations at the time of inspection.
-26309294 2012-04-19 Identification faded.
-288561532 2014-02-28 No noted violations. It looks like there could be a small leak on the 2" ball valve developing. And the identification is beginning to fade. I notified field supervisor of potential issue.
-307779600 2008-12-03 No violations were found.
-320252923 2008-02-25 No violations were found at the time of inspection.
-326552695 2010-07-14 Dike is free of water, and oil has been cleaned up.
-340581060 2012-06-25 No violations.
-382985498 2011-03-07 Annulus had slight vacuum then zero. Injection 1/4" needle valve is not opening well and needs to be replaced. Tan colored oil in dike around pump house and wellhead, 3/4" deep in dike. Accompanied by Meigs Inspector Josh Garland. I called Bob Adams and left message Re: annulus needs tested and replace 1/4" valve. Dike has oil in it from the pump house that must be cleaned up. I stopped by American Natural Gas office and told Sue about the violations and what needs to be done to correct them. 9-3-05(A)6
-382985498 2011-03-07 Annulus had slight vacuum then zero. Injection 1/4" needle valve is not opening well and needs to be replaced. Tan colored oil in dike around pump house and wellhead, 3/4" deep in dike. Accompanied by Meigs Inspector Josh Garland. I called Bob Adams and left message Re: annulus needs tested and replace 1/4" valve. Dike has oil in it from the pump house that must be cleaned up. I stopped by American Natural Gas office and told Sue about the violations and what needs to be done to correct them. 9-3-07(F)
-428472103 2010-09-27 Cracks in dike need to be filled. Dike must be liquid tight. Oil barrel is over flowing inside dike. The injection test valve is 8 feet off the dike floor. The test valve needs to be lower and located on the well side of the check valve. Ideal location for test tee would be directly above the valve on the tubing. 9-3-08(A)
-441215572 2004-07-20 Unable to measure annular pressure. The needle valve was corroded shut. Notified operator. 9-3-05(A)3
-447861061 2005-08-11 Preformed mechanical integrity test. The well passed the test with a 4% loss in pressure.

Start time: 11:26 Start pressure: 705 psi. Finish time: 11:41 Finish pressure: 676 psi.

-482224792 2005-06-23 No one at the service rig. It appears the pipe is being tested.
-496087136 2003-04-09 Met with Frank Herald(owner) on site to explain what is needed and required of Herald Oil to comply with this NOV. Will extend NOV until 5/9/03.
-519944651 2011-03-08 Cleaning up oil in dike. 80 % has been removed. Clean up is on going. Scheduling a annulus test.
-568594611 2009-08-18 Has identification. Dike has oil and water in it. Dike needs cleaned up. Concrete dike has cracks that need patched.
-608223106 2004-08-17 The annular pressure needs reduced. Spoke with the operator regarding this matter.
-645732800 2008-06-12 No violations were found.
-650989428 2004-06-23 No violations at the time of inspection.
-73847225 2009-11-24 Zero pressure on annulus. Need to do mechanical integrity test on annulus. 2" valve on annulus needs to be replaced. Needle valve on injection needs to be replaced. Concrete dike has cracks that need to be patched. 9-3-07(F)
-748286452 2003-03-05 An inspection of the site revealed that the brine trucks are not using unloading pad properly, trucks not on pad, this is violation of construction requirements. Wrong Permit # on ID at tanks, oily sand indike around tanks, oil and brine under plastic liner in dike. UNLOAD BRINE TRUCKS ON UNLOADING PAD PROPERLY OR BUILD PAD LARGE ENOUGH TOO. CORRECT PERMIT # ON ID STICKERS, CLEAN UP AND REMOVE ALL CONTAMINATED SOILS IN AND UNDER PLASTIC LINER IN DIKE. 9-3-04(A)
-748286452 2003-03-05 An inspection of the site revealed that the brine trucks are not using unloading pad properly, trucks not on pad, this is violation of construction requirements. Wrong Permit # on ID at tanks, oily sand indike around tanks, oil and brine under plastic liner in dike. UNLOAD BRINE TRUCKS ON UNLOADING PAD PROPERLY OR BUILD PAD LARGE ENOUGH TOO. CORRECT PERMIT # ON ID STICKERS, CLEAN UP AND REMOVE ALL CONTAMINATED SOILS IN AND UNDER PLASTIC LINER IN DIKE. 9-3-05(A)6
-760500646 2005-07-12 Plugged back well.
-792190530 2006-07-11 There were no violations at the time of inspection.
-851042783 2013-12-19 Inspected the containment dike, tanks, injection pump, injection line, unloading pad, injection pressure, and annulus pressure. A 4' area around a new filter housing had a skim of oil residue in the dike. I asked the well tender about this and was told that the oil is from spillage during filter changes. I suggested installing a tee with valve and a line to the sump for draining the filter housing prior to filter changes. Instead of draining the filter housing into the dike.
-909771906 2006-02-22 No violations were found at the time of inspection.
-970616252 2012-12-11 Inspected injection tubing pressure, annulus pressure. Inspected dike, tanks and unloading pad. Took brine sample from injection line in pump house. Transported brine sample to Jackson office for shipment to lab. An empty 4200 gallon plastic tank was seen inside the dike.
1070648922 2003-12-04 No violations at the time of inspection.
1127139298 2005-08-10 Waited for cement bond log to be completed. Then, witnessed the packer installation.
1167241693 2012-08-22 Upon inspection it was noted the annular space was on vacuum. Injection operations shall cease immediately and a mechanical integrity test shall be performed. 9-3-07(H)
1223492827 2005-11-04 There were no violations at the time of inspection.
1285061708 2013-04-12 Inspected the containment dike, tanks, pump house, unloading pad, injection pressure and annulus pressure. Identification on wellhead. Dike was free of water. Ohio Oil Gathering truck on site to haul oil from the 100 barrel steel tank.
1319266937 2007-09-12 There were no violations at the time of inspection.
1333565423 2012-02-17 Identification is faded. I called Bob Adams and told him to remark the identification.
1345728188 2012-08-23 Less than one gallon of fresh water was used to fill the annular space. 345 pounds were placed on the annular space and less than the allowable 5% loss was observed over the fifteen minute testing period. Less than five pounds total were lost.
1345829422 2012-08-24 The company had just re-plumbed the well. I stopped in to check the injection pressures. There were no violations at the time of inspection.
1352102150 2011-07-12 No violations
1370527418 2013-06-06 No violations.
1402009417 2014-07-24 No noted violations.
1440203876 2013-01-17 The well head pressures were tested while the pump was running. The pressure on the injection tubing was 240 psi and the annular space was on a vacuum. The owner shall cease all injection operations immediately until the it is determined that the mechanical integrity has been reestablished. 9-3-07(H)
1553650682 2009-03-17 The annulus pressure could not be gauged, due to a stuck valve.
1734299107 2006-05-17 No violations were found.
1747703017 2014-05-15 Inspected the unloading pad, containment dike, tanks, injection line, injection pump, annulus pressure and injection pressure.
1840767163 2007-10-22 There were no violations.
185809969 2008-04-21 No violations were found at the time.
1887374859 2004-05-03 No violations at the time of inspection.
1906886227 2006-08-14 There were no violations.
1936987605 2005-07-21 Running 4-1/2 inch casing into the well.
1961170410 2004-03-09 No violations at the time of inspection.
2002938105 2011-11-07 Dike free of water. Id faded.
2009122212 2005-07-20
2086199067 2013-10-15 Inspected the unloading pad, containment dike, tanks, annulus pressure, and injection pressure. Containment dike is free of water. Collected a brine sample from a valve on the injection tubing between the filter housing and the well.
371610610 2009-06-08 9-3-05(B)4
40540500 2014-06-05 No noted violations.
443699882 2006-03-30 Pressures were measured while the pump was off.
513328171 2008-09-17 There were no violations at the time of inspection.
703919485 2010-03-18 Good identification. Dike has been cleaned up.
800256612 2004-04-08 No violations at the time of inspection.
869079438 2003-03-05 FOLLOW UP TO NOV # -748286452 An inspection of the site revealed that the brine trucks are not using unloading pad properly, trucks not on pad, this is violation of construction requirements. Wrong Permit # on ID at tanks, oily sand in dike around tanks, oil and brine under plastic li 9-3-04(A)
869079438 2003-03-05 FOLLOW UP TO NOV # -748286452 An inspection of the site revealed that the brine trucks are not using unloading pad properly, trucks not on pad, this is violation of construction requirements. Wrong Permit # on ID at tanks, oily sand in dike around tanks, oil and brine under plastic li 9-3-05(A)6
933651915 2007-06-06 No violations were found at the time.
96680467 2010-11-24 Dike is free of fluids.
970248812 2009-12-15 Test annulus at 990 psi for 15 minutes. At 5 minutes 985psi, At 15 minutes 980psi. A new 2" ballvalve and a new 1/4" needle valve has been installed. Has id at well. They are pressure washing the dike and preparing for sealing the cracks. Released pressure on annulus down to 90psi. Injection at 180psi
PL10659 Preliminary Restoration done information from Data Point
UIC1501 1994-06-17 1501: 9-9-05 (A) (9) REMOVE FLUID - DIKE
UIC1579 1995-05-18 1501: 9-3-07 (E) QUARTERLY REPORTS
UIC1719 1998-05-20 1501:9-3-07 (E) (F) QUARTERLY REPORTS
UIC430 1987-12-08 1501:9-3-7 (E)(F)