34-155-23196

Well Details

Well ID: 34-155-23196
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1988-04-07
Unconventional:
Horizontal:
Producing: No
Violations: 0
Latitude: 41.268403973
Longitude: -80.8913347351

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1171463952 2013-11-22 The well was flowing gas and water. The owner was required to postpone packer installation.
-1236373346 2013-11-26 A mechanical integrity test was performed on the well. 1135 psi. of pressure was placed on the tubing/casing annulus. The test passed.
-1745147343 2013-11-25 The packer installation was witnessed. A Weatherford dual element packer was ran on 2-7/8 inch tubing.
-472998540 2013-11-12 Contractor will blow down the well and attempt to tighten 4 1/2 inch casing.
-649082053 2014-06-10 The pump was operating at the time. No violations were found.
1023157577 2013-09-26 No action has been taken to convert the well from production to injection.
1349118946 2012-09-11 The well owner has applied to convert the well from production to saltwater injection. The well site was inspected as part of a field review. There are no water wells within 300 feet of the well and proposed facility location. The well is located within what may be wetlands. Additional permit requirements may be warranted.
1384800522 2013-11-15 The 4-1/2 inch casing was tested with 1180 psi. of pressure. The pressure held, without a loss, during a fifteen minute test period.
1616035129 2013-11-19 The bottom hole cement plug was tagged at 4169 feet. A bridge plug was set at 4160 feet. The well was treated with acid. Conditions were acceptable.
1785123789 2014-01-31 There were no violations found at the time.
671613497 2014-05-16 The pump was not operating. No violations were found at the time.
716047444 2013-12-04 A mechanical integrity test was performed on the flow line. A pressure of 1080 psi. was held on the flow line for fifteen minutes. The test passed.
869889491 2014-03-18 The well was not in operation at the time. There were no violations found.
PL3279 Preliminary Restoration done information from Data Point