X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-009-22095

Well Details

Well ID: 34-009-22095
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1980-10-06
Unconventional:
Horizontal:
Producing: No
Violations: 2
Latitude: 39.1955239143
Longitude: -82.0288188754

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1220686405 2012-09-12 Repairs still have not been made.
-2040023230 2012-08-31 Tape had been used to seal the leak on the line. I spoke with the owner about repairing the line.
-392938667 2012-08-13 Associated with complaint #3496. Well used for domestic purposes. A one inch plastic line ran from the separator to the house had a small leak releasing gas to the atmosphere. Line shall be repaired or replaced. Discussed issue with owner. 9-9-05(A)1
-392938667 2012-08-13 Associated with complaint #3496. Well used for domestic purposes. A one inch plastic line ran from the separator to the house had a small leak releasing gas to the atmosphere. Line shall be repaired or replaced. Discussed issue with owner. 9-9-05(A)8
-73610254 2012-08-15 This visit was the notice for inspection # 392938667. The well was in violation for 9-9-05 a(10) and a(8). I originally visited the well on 8/13/12. Spoke with the owner of the well this day, and let him know he would need to have the line repaired or replaced. Accompanied by Morgan Button.
-761423913 2012-10-22 The 2" sales line with the leaking clamp is being replaced.
1084921118 2006-04-05 The well was equipped with a rabbit and a separator. There was no ID. The well appears to be producing, but not for domestic use.
1345568025 2012-08-21 Associated with complaint # 3496. This well is registered under Domestic status. The leaky 2" plastic line has not been repaired or replaced yet.
1346337384 2012-08-29 The line to the owners house was still leaking a small amount of gas. I stopped by the owners house to ask about the repairs and was unable to speak to the owner.
1349117301 2012-09-27 The line has not yet been repaired and is still leaking gas.
913262768 2012-11-07 Follow up to inspection -392938667. The leaking 2" plastic line has been replaced with a 1" steel line.