If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-009-21546 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.3409185303,"lon":-81.9501238494,"icon":""}]} |
County: | |
Municipality: | |
Operator Name: | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: | |
Unconventional: | |
Horizontal: | |
Producing: No | |
Violations: 4 | |
Latitude: 39.3409185303 | |
Longitude: -81.9501238494 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
-704947287 | 2013-11-22 | The landowner asked to meet me at the well to discuss concerns of his. Well equipped with a pumping unit with no powersource. No identification at the well. The tubing was plumbed into a 2" sales line. The line was equipped with a T fitting near the wellhead. One section of line was reduced to a 1" nipple with a partially open gate valve. No sign of contamination, but there was a smell of gas. The other section of line had a 2" gate valve in the closed position. | 9-9-05(A)1 | |||
-704947287 | 2013-11-22 | The landowner asked to meet me at the well to discuss concerns of his. Well equipped with a pumping unit with no powersource. No identification at the well. The tubing was plumbed into a 2" sales line. The line was equipped with a T fitting near the wellhead. One section of line was reduced to a 1" nipple with a partially open gate valve. No sign of contamination, but there was a smell of gas. The other section of line had a 2" gate valve in the closed position. | 9-9-05(A)10 | |||
-704947287 | 2013-11-22 | The landowner asked to meet me at the well to discuss concerns of his. Well equipped with a pumping unit with no powersource. No identification at the well. The tubing was plumbed into a 2" sales line. The line was equipped with a T fitting near the wellhead. One section of line was reduced to a 1" nipple with a partially open gate valve. No sign of contamination, but there was a smell of gas. The other section of line had a 2" gate valve in the closed position. | 9-9-05(B) | |||
-716271123 | 2013-07-25 | Follow up to -795571006. No clean up. | ||||
-795571006 | 2013-06-19 | The landowner had concerns about the well and apparent lack of maintenance. The well was equipped with a pumping unit with no power source. Tank battery consists of one 100 Barrel (Bbl) steel tank, one 80 Bbl steel tank and one 2600 gallon poly tank. There is a scalded are inside the dike roughly 20 x 20' that registered 280ppm Chlorides when field tested. Contaminated soils shall be removed and disposed of properly. Any affected areas shall be reseeded and mulched and steps shall be taken to encourage vegetative cover. I spoke with the producer at the well site. | 9-1-07 | |||
-87563097 | 2014-02-21 | Follow up to -704947287. Ground around well head dug up and work has been done. The back flow preventor is still leaking. | ||||
-95647606 | 2014-03-31 | Follow up to -795571006. No clean up has taken place at the tank battery. | ||||
1385562353 | 2013-11-27 | Follow up to -795571006. No clean up. | ||||
1395754133 | 2014-03-25 | Follow up to -795571006. The lines at the wellhead are no longer leaking, the backflow preventor has been replaced with a plug. There has been no clean up at the contaminated area around the tank battery. | ||||
1403271650 | 2014-06-20 | Follow up to -795571006. The contaminated soils have been removed, the dike has been reconstructed, the new tank will be placed into the dike soon. | ||||
1949891169 | 2014-02-19 | Follow up to -795571006. There is still a scald area inside the dike and standing water at the lower side of the dike. Spoke with Roger Stright, issued a 4 week extension to restore vegetative cover due to weather. | ||||
305604878 | 2014-02-19 | Follow up to -704947287. Pumping unit has no power source and is overgrown with vegetation. Valves on tubing open and line is open to air with no plug. There is also a line that is plumbed into either the production or surface casing and is also open to air. Gas seen escaping from this line. Unable to tell which string of casing this line is tied into because most of well head is below ground. Spoke with Roger Stright issued a 2 day extension to get a plug in the back flow preventor. |