If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-167-23862 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.3479439714,"lon":-81.5905304061,"icon":""}]} |
County: | |
Municipality: | |
Operator Name: | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 1977-08-12 | |
Unconventional: | |
Horizontal: | |
Producing: No | |
Violations: 0 | |
Latitude: 39.3479439714 | |
Longitude: -81.5905304061 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
-1130167643 | 2012-01-24 | Inspection this day found floor and dike walls of containment area poured. Progress moving along slowly. | ||||
-144438819 | 2013-02-28 | Inspection revealed that well is not used much and facility is in satisfactory condition this inspection. | ||||
-2017932471 | 2011-08-01 | |||||
-271624816 | 2013-03-29 | Inspection revealed that injection pump was not in operation today and it appears that well is not used much. | ||||
-682921069 | 2012-11-05 | On site to witness testing of flow line and also to apply pressure to annulus of tubing, Sweeny Well Service applied 1000 psi of pressure to annulus of tubing and we monitored pressure for 15 min with no decline which indicated that we have good integrity of production casing and packer is holding fine and also we filled flow line with fresh water and applied pressure to it also with no decline in pressure ,facility is ready to go online once storage tanks are filled with brine. | ||||
-698225792 | 2011-07-19 | Stopped by location, found locked gate in lease road and could not get to well - Knox Energy said they would be on location but nobody there this day. Stopped by Constitution and talked to them for a hour. | ||||
-959342423 | 2012-03-05 | My inspection this day due to quarterly requirements. I appears nothing more has been done on the storage site - dike wall and floors poured concrete but no equipment inside. I am hearing that well is for sale - several operators have been contacted. | ||||
12211028 | 2013-01-31 | Inspection revealed that there was no activity at site today, facility is locked up and I was unable to check pressures today due to fact that owner has not given me a key to unlock gates going to pump house or unloading area. | ||||
123687382 | 2011-07-29 | Today, casing pressure at zero when arrived. Rig continues to run packer on tubing to 4300', set packer. Producers Well Service on location, first did pressure test on casing to 2000# - well held and did not drop. Next to do volume/pressure test on zones to see if zones will take water. With packer at 4300', well took water at 2.5 bbl/min at 1000-1200#, water going in Oriskany, Clinton and Medina. Next lowered packer to 4457", below the Oriskany but above Clinton and Medina. These lower zones would not take water - after only 7 bbl, zones were taking water at 1 bbl/min and up to 1850# and still climbing. Records show well was fracted with no notes on staging, baffles, to indicate whether all the zones were treated. I suspect, fract only went to Oriskany zone. Owner satisfied that with salt water, well will take water at lower pressure and wants to put it into production as is. Feels he wants to get some of investment back and can acidize/fract lower zones at future date. | ||||
1311767348 | 2011-07-26 | Inspection this day found crew (Berry Well Service) waiting on 2nd fishing tool. Spent 7/22 trying to pull rods, tubing - pump stuck, couldn't get wellhead off, on Monday (7/25) cut wellhead off, tubing dropped 15', 7/26 got fishing tool - overshot size 3 15/16ths, would not go into casing - at this time waiting for bigger overshot tool from WVA. Feel pump is salted in, well has not been worked since 1989. Should come soon and will be able to retrieve tubing, pull well. | ||||
1321291544 | 2011-11-14 | Operator had called last week to say they were pouring concrete for the tank pad/containment. My inspection this day found that the pad/dike was still framed up with re-bar but no concrete had been poured. | ||||
1336000023 | 2012-05-02 | On site to witness injection testing of well, Producers Services pumped water at a rate of 1.3 bpm and we monitored pressure and we also tested flow line to well@ 1480 psi with a 2% pressure loss and we monitored annulus pressure while pumping and no pressure was recorded it appears that casing has good integrity and packer is holding once testing is complete plans will be made to complete construction of facility. | ||||
1339540422 | 2012-06-12 | No recent activity at site since last inspection well is not in operation at this time waiting on surface facility construction. | ||||
1346455855 | 2012-08-30 | Inspection on this day revealed that well is currently not in active injection status new owner is planning on making upgrades to current site before placing well in to active injection status. | ||||
1347136978 | 2012-09-07 | Inspection revealed that contractor on site hauling stone to place around tank site and grade off place for vault tank and possibly set tank early next week. | ||||
1350342401 | 2012-10-15 | Inspection revealed that well is still under construction storage tanks have been set and plumbed up and injection pump has been set and filter housings also have been put in place they are installing electric service at facility and once installed we will pressure test plumbing and place well into operation. | ||||
1353444553 | 2012-11-20 | Inspection revealed that injection pump was in operation during my inspection and facility was in satisfactory condition this inspection. | ||||
1354231762 | 2012-11-28 | Inspection revealed that injection pump was in operation during my inspection and it was noted that two company owned vacuum trucks were unloading at facility during my inspection. | ||||
1356634496 | 2012-12-27 | Inspection revealed that well was not in operation today due too bad weather conditions for vacuum trucks to be on county road. | ||||
1363638881 | 2013-03-18 | Inspection revealed that well was not in operation today but it was noted there was evidence of recent truck traffic at facility. | ||||
1374877470 | 2013-07-24 | Inspection revealed that injection pump was in operation during our inspection and it was noted that one company owned vacuum truck was unloading at facility during our inspection.
Note: Lease road to wellhead will need to be graded and water bars installed to help prevent erosion at site. |
||||
1379700563 | 2013-09-20 | Inspection revealed that injection pump was in operation during my inspection and it was noted that storage tanks and well head has been painted since my last inspection.
Note: Told operator that positive pressure is needed on annulus of tubing ASAP. |
||||
1398091487 | 2014-04-21 | Inspection revealed that injection pump was not operating during my inspection and it was noted that two company owned vacuum trucks were unloading at facility during my inspection. | ||||
1902566814 | 2013-12-03 | Inspection revealed that injection pump was not in operation today and it was noted that facility does not appear to be used much at this time. | ||||
463045719 | 2014-03-10 | Inspection revealed that injection pump was in operation during my inspection and it was noted that annulus pressure has dropped to zero, contacted company rep and requested that positive pressure be applied to annulus in the near future. | ||||
486260474 | 2014-03-25 | On site to witness owner apply positive pressure to annulus of tubing to verify casing integrity. | ||||
513591097 | 2014-06-26 | Inspection revealed that injection pump was not in operation during my inspection and it was noted that one Hall Drilling vacuum truck was unloading at facility during my inspection UIC#361. | ||||
637946463 | 2012-04-11 | Information this day from the owner, Mrs. Nichols, that they have a contract to buy this facility - is still unfinished and has no tanks or pump. Mr. Bruce Huffman says they will come in and do another volume test before acquiring. They have plans to do this fairly soon. I was at facility this day and found no activity yet. | ||||
735774163 | 2013-07-24 | Accompanied UIC III inspector Dave Ball on inspection of this well and tank battery. | ||||
83569378 | 2011-07-28 | 7/26 - pulled rods, 7/27 - pulled tubing - found tubing hanger at bottom, started back in with 4" Parmaco set-down packer, 7/28 - finished running tubing, set packer, tested formations for water injectability with Formation Cementing pump truck. Pressured up to 1750#, pump truck not working correctly and can't give it a proper test to see if 4.5" casing will hold pressure. Will have to try again tomorrow. Put 1500# on the well, will see what it reads in the morning. Do not want to proceed further if casing is no good. | ||||
99395977 | 2013-04-11 | On site to pressure test annulus of tubing, Sweeny Well Service pumped 5 gal water and inhibitor to perform test they pressured up to 1000 psi and we monitored pressure for 15 minutes with no decline in pressure.
Note: Operator stated that they are not receiving much water at this time. |