Well ID: 34-085-20883 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.7654402567,"lon":-81.15697516,"icon":""}]} |
County: | |
Municipality: | |
Operator Name: | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 1987-08-27 | |
Unconventional: | |
Horizontal: | |
Producing: No | |
Violations: 0 | |
Latitude: 41.7654402567 | |
Longitude: -81.15697516 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
-1219205171 | 2012-04-25 | My inspection today is to follow up on a complaint from the mayor of Perry Village. The operator changed the well from a plunger lift system to a pump unit. The land owner south of the well, has a patio and sun room that faces the well. The neighbor had inquired about a visual barrier. The operator of the well installed a wood visual barrier wall. The wall blocks the view of the pump unit for the neighbor. | ||||
-1337553467 | 2012-02-09 | The rig is tripping tubing back into the well. The operator will be installing a pumping unit and is going to fence well with board on board fencing. | ||||
-1560591429 | 2012-03-29 | The Mayor of Perry contacted me in regards to a visual barrier for this well. This well was converted from a plunger lift system to a pumping unit. The landowner, who purchased the adjoining lot south of the well, built his house with the sun room windows facing directly at the well. The well has been fenced with new 6' chain link. I spoke Ron Gibson, who will install a section of 8' board on board fence to block the the view of the well from the home. I spoke to the landowner immediately west of the well and he stated that the well is not an issue for him as his shed blocks any view of the well. The Village of Perry does not allow buildings within 300' of a gas well. I notified the Mayor, who asked for my opinion on the village spacing rules, that ORC 1509 requires 150' spacing for an inhabited structure to a wellhead in urban areas, unless the landowner approves a waiver for 100' and for unoccupied structures, there are no rules. | ||||
1000767226 | 2013-10-02 | The producing unit consists of a pump jack unit at the wellhead and an aboveground storage tank (AST) battery. The battery is comprised of 1 100-barrel steel production tank and a separator unit. The elements are enclosed in separate chain-link enclosures. There is adequate secondary containment and signage. No problems noted. The battery is shared with the #882, and #884 units. | ||||
9295 | PASSED Y WITNESSED 6/26/91 INSPECTOR SINN,SHIRLEY DATE 06/2619/91 DATA FROM OLD VAX INFO |