34-079-20138

Well Details

Well ID: 34-079-20138
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1981-12-16
Unconventional:
Horizontal:
Producing: No
Violations: 3
Latitude: 39.0081506733
Longitude: -82.6366364065

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1188408547 2007-08-02 Well is capable of production, all valves are open. Id is on the ground beside the well.
-1193717496 2004-10-13 FOLLOW UP TO NOV # 1537997171 No ID; small brine scald area. Shut-off. NONE
-157175075 2004-10-13 Extension of NOV correction deadline. NONE
-2094333585 2012-09-18 Inspected the three shut-in ARTEX wells (Trepanier 1&2, API 34079201020000 & API 34079201380000) and Garrett #2 (API 3407920206) with Don Huck (Exploration Manager for Artex) and Dean Harris (oiler for Artex). Found all three wells were leaking gas between the 2-3/8 inch production tubing and the $-1/2 inch intermediate csg at the tubing ring on the casing head. I expect them to contact me by this coming Thursday 09/20/2012 on what they plan to do or that they have corrected the problem. Don contacted me on Wednesday 09/19/2012 that the leak has been fixed. I field checked the wells with the Honeywell PHD 6/ PID gas meter and doused with bottle water covering where the leaks occurred and there was no reading on the meter and no bubbles where the leaks occurred earlier. NONE18
1537997171 2004-10-13 No ID; small brine scald area. Shut-off.
309870370 2012-11-08 Performed Temporary Inactive Audit for Artex's TI application. Dean Price, Artex's well tender for this well, accompanied me on this audit and provided access to this well. Checked all valves to be sure they were closed; no leaks were measured with the Honeywell PhD6 gas meter nor observed by myself; all gas lines on the sales side of the well head including the gas line to Jackson were empty according to Dean Harris and have been since this well was shut in. The well meets the requirements for TI status.