X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-045-21115

Well Details

Well ID: 34-045-21115
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1992-04-07
Unconventional:
Horizontal:
Producing: No
Violations: 3
Latitude: 39.7346929075
Longitude: -82.4361240176

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-722494972 2005-01-07 Well was transferred from Ardent Resources, Inc. to Geopetro LLC on 12/09/2004. Follow-up inspection revealed ID posted and well is capable of production. No violations noted this date.
1054830094 2003-06-05 Follow-up inspection revealed well is still incapable of production and no domestic gas is being used from the well. An inspection of production recorders revealed owner has not filed productions since 1997. I took three (3) photos of the location. OWNER NEED TO DO THE FOLLOWING. 1) PLACE WELL INTO PRODUCTON 2) PROPERLY PLUGG SAID WELL. NOV SENT CERTIIFED LETTER No. 7099 3400 0004 5169 2700. WEATHER CONDITIONS: Mostly sunny and 65 degrees. NONE
1056133052 2003-06-20 Follow-up revealed no change in the wells status.
1210i4253340 2001-08-07 Well is incapable of production. Pump jack removed. All valves closed at wellhead. No Id at well or tanks. Has single 100bbl. Tank. Refer to Keith White.
1306252319 2011-04-08 The Division received a complaint alleging that gas line has broke at wellhead location. An inspection revealed 1.25" gas line at well contained a hole. The well was shut-in and no leakage was observed. No identification observed at the well or tank battery location. The well owner was notified of inspection results. 9-9-05(A)10
1306252319 2011-04-08 The Division received a complaint alleging that gas line has broke at wellhead location. An inspection revealed 1.25" gas line at well contained a hole. The well was shut-in and no leakage was observed. No identification observed at the well or tank battery location. The well owner was notified of inspection results. 9-9-05(A)8
1373554025 2013-07-11 I inspected the well as a request from the landowner Cory Snoke. He asked about the non production of this well. I spoke with Bill Archer who stated he will plug the well or sell the well to the landowner. The landowner, Cory Snoke stated he would try and purchase the well from Geopetro.
206239270 2012-01-20 Site inspection, howmowner request to ensure compliance, tank battery and pumping unit in good condition, no violations noted.
30574157 2002-03-20 WEATHER CONDITIONS: Cloudy, rain and 42 degrees. Well is still shut in at the well head. (Took two (2) photos.
527196716 2014-08-15 Exempt pre transfer well inspection. I received a request from Central Office, Vickie Mckinney to determine if the well meets minimum standards for exempt well ownership. The well is being used for domestic use. The well is owned by Corey and Nina Snoke. The well is in compliance.
929190058 2011-08-16 A follow-up inspection revealed compliance.