X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-083-24137

Well Details

Well ID: 34-083-24137
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1998-02-28
Unconventional:
Horizontal:
Producing: No
Violations: 1
Latitude: 40.357869066
Longitude: -82.2446249602

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1028461976 2011-09-26 An inspection revealed no violations. The well owner's gauge placed on the injection side of well was used to record only the injection pressure for this inspection. Attempts to remove this gauge were not successful, due to being seized to 1/4" fitting therefore, opted to prevent damage to company equipment. Injection pump would later turn on and pressure showed 580-590 psi on murphy switch. During the inspection, UIC Brine Hauler, EC Nabors (Energy Contractors), UIC #25 335, Lic # BA 522956, arrived with 100 bbls from the following: Lease Name 590-373, Producer 37 031-25296, Clarion, Pennsylvania. Note: Company has scheduled 7 trucks for disposal today.
-1126390854 2014-07-08 Inspect Summit Environmental Services brine hauling truck UIC 534. Log and truck are ok.
-125830933 2014-08-13 Inspect brine truck at location and unloading. Summit Environmental Services UIC#25-534, Trick # 1913 driver Steve Smith deliver flow back water from Antero's Revival Lease from Doddridge County, West Virginia (API#47-017-06218-00).
-1266507608 2014-04-03 Inspect well. Check injection and annulus pressure. Pump shut down during inspection.
-1444622319 2013-03-11 Inspect Brine hauler UIC 411, Shortfuse Gasfield Trucking LLC., Truck #91, Trailer #7. Deliver water from D&L Energy, storage frac tanks in the Youngtown area. Field measurement for pH is 11, the preserved sample pH is 1.0, Quantab is greater than 1 % Nacl.
-1566891858 2014-04-03 Inspect three brine haulers at well head. Inspect truck and brine log for Oil Field Tucking Solutions UIC 485 for trucks 275, 279, and 269.
-1631923853 2013-02-11 Collect brine water sample for chemical analyses from Bessemer Supply UIC 25-391 tuck. Truck number 3848, drive; Larry Lawrence. Sample ID TSB020. Source for water Butler PA; 37-019-21894; Pallack Unit 1H, Drilled by Rex Energy Operating Corp.
-1651848344 2013-09-05 Inspect well for integrity and pressure.
-1853280632 2012-07-20 During inspection I was accompanied by Jeff Fry. We measured the dike and the dimensions were 50' by 32' by 28". This satisfies the capacity needed for containment. Upon inspection we found one of the tanks to be leaking from the 10" manifold on the front of the tank. We tested the water leaking from the tank with a Quantab test strip. The test strip read >2022 ppm for chlorides. The water was being contained inside the dike. I informed Mike Chapin by phone of the leak. Chris with Elkhead arrived during inspection and informed us he would fix the leak. We told Chris that we would check back later in the afternoon to see if the leak has been stopped. While we were at the injection well a brine hauler operated by Waste Management was unloading a tank of water. The truck driver was Chord Fleming. I asked to see his log book and it was filled out with all the correct information.
-1919994617 2012-04-26 Today I conducted a well inspection on the Chapin salt water injection well #8 accompanied by Jeff Fry. No ID was posted. I spoke with one of the employee's at the injection well and said he would get one posted that day.
-1953720916 2014-07-08 Inspect Hall Drilling LLC brine hauling truck UIC 361. Log is ok. Phone number of transporter is not on truck.
-2022082769 2012-12-13 I witnessed Mike Chapin install a new concrete vault today that will catch any fluid that is spilled on the concrete unloading pad. The vault is 9 feet long by 6 feet wide and has a capacity of 1,500 gallons. The vault will also be used to store water that is pumped from inside the tank battery dike. The vault will have a sump pump that will pump fluid back into the storage tanks.
-2097227786 2012-07-20 I was accompanied by Jeff Fry as we returned to inspect the leak on the storage tank. The leak was fixed and the dike has passed inspection. We tested the injection well pressure during inspection. The pump was running during the test. The well is in compliance with the maximum allowable pressure.
-273066642 2013-04-10 Collect brine sample from Bessemer Supply, Truck #3848, UIC #25-391. Load delivered from Breakneck Beagle Club Well # 28-01, API # 3701921955; Jackson Twp., Butler Co., PA.
-449915075 2014-07-08 Inspect B&J Drilling Co. Inc. brine hauling truck UIC 42. Truck and log are ok.
-523934123 2013-02-21 Rocky King's Inspection revieled that Pa Energy Services brine hauler at the time was not a registered hauler with the state of Ohio. Records show they are a registered brine hauler in the state of Ohio.
-535662225 2012-08-27 I was accompanied by Tom Benko today as we collected water samples from the tank battery at Elkhead's disposal well. No trucks were unloading at this time.
-676972264 2012-08-01 I was accompanied by Jeff Fry today as we sampled water from the tank battery on SWIW #8 for Elkhead Gas and Oil.
-863631694 2011-11-28 An inspection revealed no violations at this time. The injection pump was running at time of inspection. The flowmeter showed 32-33 gallons/minute and 275,730 gallons x 10. The storage tank facility consisted of (7) 210 bbl tanks. Note: Rainfall event at time of inspection. During the inspection, UIC Brine Hauler, EC Nabors (Energy Contractors), UIC #25 335, was at the location with 125 bbls from the following: Eastern Natural Gas, Lease Name: Statler #1H3H, API: 47-61-01625, location: Manangalia, WV.
-9794888 2012-08-27 Inspect well with Brandon Mitchell. Site ok. Collect water sample for chemical analysis.
1120397614 2012-07-16 Today I inspected the well location. No violations were observed. During inspection a brine hauler operated by B & J Drilling was unloading water at the tank battery. I asked to see the brine log and the driver has kept it filled out with the correct information.
1277191840 2014-07-08 Inspect well for integrity and pressure. Pump in operation at 960.9 bbl/day.
1278949388 2010-07-12 Jeff Fry and I inspected the well location today at the request of Tom Tomastik from the Division. There is an application to convert this deep well into a salt water injection well. There is an active pumping unit on the well and the well is capable of production. There is a tank battery location that contains one 200 barrel tank. There is proper identification posted. Vegetation is well established on the location and there are no signs of erosion or water run-off problems. The closest water well is approximately 250 feet away at location: N 40.35727, W 082.24402. The second closest water well is across the road at location: N 40.35703, W 082.24373. There are no other water wells or surface bodies of water that are within close proximity of this well and probable tank battery location.
1287i487 2001-12-17
1290440827 2010-11-22 On site to witness the installation of liner in diked area.

Liner was put down then a layer of sand was put over top of it. Then a second liner was put down and another layer of sand was put over top of the whole area.

1291041416 2010-11-29 No one at the site, the dike has been inclosed ane the storage tanks have been set but not hooked up yet.
1308956112 2011-06-24 9-3-07[C]
1344600764 2012-07-18 Today I met with Mike Chapin of Elkhead Gas and Oil. Elkhead is building a temporary tank battery for the injection well consisting of two 500 barrel frack tanks. The tanks were set on a plastic liner and an earthened dike was being built around the tanks for containment. I left before the dike was finished but informed Mike Chapin that I would return to inspect the dimensions of the dike when he was finished.
1352982388 2012-11-13 Collected brine sample TSB014. Marcellus Shale production brine delivered by Castelli Oil & Gas, New Lexington PA UIC:25-528 was collected from the truck. Source of water is from 3712524158; EQT Production Co.; Kevech Well #590468; Washington County, Followfield Twp. PA.
1385126023 2013-10-24 Inspect well for integrity and pressure.
1385570665 2013-11-26 Inspect well and storage system. Operator is rebuilding pump.
1408706552 2014-08-19 Inspect brine truck at wellhead unloading pad. Summit Environmental Trucking UIC#534 truck LV2213. Source water 110 bbl of flowback from Antero's Revival 47-017-06218-00 Doddridge County, West Virginia.
1409312226 2014-08-27 Inspect facility. Inspection pump in operation during inspection. B&J Drilling UIC 42 truck was at the unloading facility during inspection.
1671854258 2012-05-10 Jeff Fry accompanied me on this inspection. Identification has been posted at the well and tank battery as well as the pump house. No violations on this date.
1705023959 2014-01-09 Inspect well for integrity and pressure.
1722766411 2011-06-24
1738922028 2012-11-05 I inspected this location today. A truck was unloading water during inspection. An Infinity Oilfield Services truck with license plate number AF98008 was unloading a truck load of water. No violations during inspection.
1864737823 2012-03-26 An inspection revealed no violations.
2116032437 2014-08-11 Collect a brine sample for chemical analysis from Halls Drilling LLC UIC#25-361. 100 bbl.'s of Flow back water from Antero's McGill well Doddridge County, West Virginia (API#47-017-06178-00). The sample was delivered to the Cambridge lab for chemical analysis.
418877214 2012-01-30 An inspection revealed no violations. A new Hague 60 HP pump has been installed since last inspection. At time of the inspection, Automation was being installed, which will allow company to monitor pressure and fluid level on tank (float installed on tank to far right, closest to rd) offsite/away from location.
482616120 2013-02-11 Inspect well and tank location. Measure dike storage area at 95 feet by 41 feet and 19.5 inches to the top of the gavel. Storage area consists of Seven(7) each 210 bbl tanks.
741352672 2013-04-10 Collect brine sample from Bessemer Supply Tuck #3848, UIC #25-391. Production water from Breakneck Beagle Club Well #28-01 API 3701921955, Jackson Twp., Butler Co., PA.
886020418 2010-12-22 New well costruction. 4) 210 Bbbl and 1) 100 Bbl tank set in lined dike. Well not hooked up as of yet.
893254905 2012-07-17 I inspected this location today. No violations during inspection. A brine hauler operated by Myers Well Service was unloading water during inspection.
iDIAN000648 1998-12-07