X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-153-21043

Well Details

Well ID: 34-153-21043
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1981-12-03
Unconventional:
Horizontal:
Producing: No
Violations: 5
Latitude: 41.2119125822
Longitude: -81.4588828651

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
1392910209 2013-06-24 I inspected this well on 6/24/2013 as a follow-up to a previously issued NOV ( # 340674533 ) dated 10/21/2005. My inspection determined that none of the corrective measures prescribed previously were performed to bring the well into compliance. The well lacked commerical production ( O.R.C. 1509 : 62 ) since 1993 , vegetation overgrowing both the tank battery and well head, lack of proper identification signage , lack of locks on the gates and load lines were violations that were identified in the previous NOV and inspection reports. Tony ( Pine Top Inc's representative ) expressed Pine Top's desire to rework the well and place back into production. Tony indicated that all that was needed was a new or repaired gas sales line to DOM / EOG. He stated that the previous deficiencies would be remedied . The Stribny # 2 consists of 4.5" casing with a 4" x @" swedge connect to a flowline. The Stribny # 2 & # 1 share a common tank battery. The tank battery is made up of a 100 Bbl. Stock tank and a horizontal 2408 separator . I could not determine if there was any pressure on the 4.5" casing, since there wasn't any gauges on the well. It is my observation that there has not been any material changes since the last inspection and issuance of the NOV in 2005. I told Tony ( Pine Top , Inc.'s representative ) that all corrective measures shall be remedied and the wells placed into production by 12/24/2013. Tony indicated that compliance would be before the deadline.
2059537364 2006-10-05 The well is still idle and must be either placed back in production or properly plugged and abandoned. 9-9-02
2059537364 2006-10-05 The well is still idle and must be either placed back in production or properly plugged and abandoned. NONE
340674533 2005-10-17 The last reported production was 2003. According to the landowner, they are not getting domestic gas. The well must either be placed back into production or plugged and abandoned. The tank battery and wellhead are overgrown and must be cleared of vegetation. The site must be inspected after the vegetation is cleared and prior to turning the well back into production. The tank battery gate and thief hatch must be closed and secured at all times. Post the required identification at the wellhead. 9-9-02
340674533 2005-10-17 The last reported production was 2003. According to the landowner, they are not getting domestic gas. The well must either be placed back into production or plugged and abandoned. The tank battery and wellhead are overgrown and must be cleared of vegetation. The site must be inspected after the vegetation is cleared and prior to turning the well back into production. The tank battery gate and thief hatch must be closed and secured at all times. Post the required identification at the wellhead. NONE
712434070 2005-10-17 FOLLOW UP TO NOV # 340674533 The last reported production was 2003. According to the landowner, they are not getting domestic gas. The well must either be placed back into production or plugged and abandoned. The tank battery and wellhead are overgrown and must be cleared of vegetation. The site must be inspected after the vegetation is cleared and prior to turning the well back into production. The tank battery gate and thief hatch must be closed and secured at all times. Post the required identification at the wellhead.
866217902 2014-02-18 I inspected the Stribny # 2 on 2/18/2014, along with Mr. Stribny and Atty. Keith Ruffener, to determine if any of the prescribed corrective measures ( NOV # 340674533 and Inspection # 1392910209 ) had been complied with. I found that Pine Top, Inc. still has not established commerical oil and / or gas production from the Stribny # 2.The last commerical oil and / or gas production ( as defined by O.R.C. 1509 : 62 ) was reported for the year 1993. The repaired or projected gas sales line to DOM / EOG never materialized and as such the well is incapable of the production of oil and / or gas. The tank battery is still overgrown with vegetation, proper identification and locks were still absent. I did not observe any corrective measures, by Pine Top, Inc. , to place the Stribny # 2 into production and correct the previously discussed violations NONE