If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-009-22327 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.4182551885,"lon":-82.1121883785,"icon":""}]} |
County: | |
Municipality: | |
Operator Name: | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 1981-12-29 | |
Unconventional: | |
Horizontal: | |
Producing: No | |
Violations: 4 | |
Latitude: 39.4182551885 | |
Longitude: -82.1121883785 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
-1186819889 | 2012-05-03 | No action taken to bring well into compliance. Extension granted due to mailing address mistake. | ||||
-1534977131 | 2012-07-05 | Spoke with Mr. Bowers, he plans to work on the well to correct violations soon. | ||||
-247180443 | 2013-03-12 | Follow up to 975943965. The ID has been posted at the tanks, the vent annulus is no longer leaking and a regulator is being used to supply gas to the pumping unit. The contamination has been cleaned up and the valves on the production and the tubing are open. | ||||
-83074264 | 2012-08-01 | The 1" line to the pumping unit has been repaired and is no longer leaking. The one gallon jug collecting the fluids from the surface casing head has been removed, but the contaminated soils remain on site. | ||||
1072435219 | 2012-06-13 | No clean up has been done at the well. The gallon jug that catches oil and waste from the 8" head is still on site. A one inch plastic line that runs gas through a drip on the bottom of the pumping unit has a crack in it and is releasing a small amount of gas. | ||||
1452650926 | 2005-09-30 | The disposal line was disconnected from the well. There were three 100 bbl tanks present. | ||||
1924754383 | 2012-07-03 | No actions have been taken to bring the well into compliance. | ||||
975943965 | 2012-02-01 | The identification on the well was missing the American Petroleum Institute (API) number. All producing leases shall be legibly identified in a conspicuous place on or near the well-head or the storage tank as to owner, lease name, well number, permit number where available, county, and an emergency telephone number. A line coming from underground and connected to the surface casing terminated in a 1" hose that emptied into a gallon plastic jug. The jug had over filled with crude oil and had contaminated the ground around the wellhead. All crude oil and contaminated soils shall immediately be removed and disposed of properly. All affected areas shall be reseeded and mulched and steps shall be taken to encourage vegetative growth. Zero production has been reported since 2005. Well shall be plugged, produced, or put in temporary inactive status. | 9-1-07 | |||
975943965 | 2012-02-01 | The identification on the well was missing the American Petroleum Institute (API) number. All producing leases shall be legibly identified in a conspicuous place on or near the well-head or the storage tank as to owner, lease name, well number, permit number where available, county, and an emergency telephone number. A line coming from underground and connected to the surface casing terminated in a 1" hose that emptied into a gallon plastic jug. The jug had over filled with crude oil and had contaminated the ground around the wellhead. All crude oil and contaminated soils shall immediately be removed and disposed of properly. All affected areas shall be reseeded and mulched and steps shall be taken to encourage vegetative growth. Zero production has been reported since 2005. Well shall be plugged, produced, or put in temporary inactive status. | 9-9-05(A)1 | |||
975943965 | 2012-02-01 | The identification on the well was missing the American Petroleum Institute (API) number. All producing leases shall be legibly identified in a conspicuous place on or near the well-head or the storage tank as to owner, lease name, well number, permit number where available, county, and an emergency telephone number. A line coming from underground and connected to the surface casing terminated in a 1" hose that emptied into a gallon plastic jug. The jug had over filled with crude oil and had contaminated the ground around the wellhead. All crude oil and contaminated soils shall immediately be removed and disposed of properly. All affected areas shall be reseeded and mulched and steps shall be taken to encourage vegetative growth. Zero production has been reported since 2005. Well shall be plugged, produced, or put in temporary inactive status. | 9-9-05(A)10 | |||
975943965 | 2012-02-01 | The identification on the well was missing the American Petroleum Institute (API) number. All producing leases shall be legibly identified in a conspicuous place on or near the well-head or the storage tank as to owner, lease name, well number, permit number where available, county, and an emergency telephone number. A line coming from underground and connected to the surface casing terminated in a 1" hose that emptied into a gallon plastic jug. The jug had over filled with crude oil and had contaminated the ground around the wellhead. All crude oil and contaminated soils shall immediately be removed and disposed of properly. All affected areas shall be reseeded and mulched and steps shall be taken to encourage vegetative growth. Zero production has been reported since 2005. Well shall be plugged, produced, or put in temporary inactive status. | NONE_ |