X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-089-24365

Well Details

Well ID: 34-089-24365
Sorry, we have no imagery here.
Sorry, we have no imagery here.
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1982-01-19
Unconventional:
Horizontal:
Producing: No
Violations: 2
Latitude: 40.0309050269
Longitude: -82.2913669023

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1377750707 2002-05-10 FOLLOW UP TO NOV # 1210i41 Well has pump jack and is capable. Tank battery has 2 100 Bbl steel tanks. Pit below tanks, has water and crude oil. No Identification. Need pit properly emptied and filled in and ID posted. No production report's filed for 1999, 2000, and 2001. Violat 9-9-05(A)10
-1377750707 2002-05-10 FOLLOW UP TO NOV # 1210i41 Well has pump jack and is capable. Tank battery has 2 100 Bbl steel tanks. Pit below tanks, has water and crude oil. No Identification. Need pit properly emptied and filled in and ID posted. No production report's filed for 1999, 2000, and 2001. Violat NONE(F)
1041640323 2003-01-03 has pump jack and is capable. Pit filled and gradedand seeded.
1210i4158728 2002-05-10 Well has pump jack and is capable. Tank battery has 2 100 Bbl steel tanks. Pit below tanks, has water and crude oil. No Identification. Need pit properly emptied and filled in and ID posted. No production report's filed for 1999, 2000, and 2001. Violation of 1509.11. Need to properly empty and close pit, post ID, and submit production reports for the years listed. Talked to land owner Mrs. McClain, not happy with well operator.
1535909333 2013-03-05 I inspected this well at the request of landowner Mr. Jarrod McClain. The well was equipped with a pumping unit but no motor. Mr. McClain informed me that the motor was pulled from the pumping unit within the past month. An earthened dike is built around the well and pumping unit. Oil had puked out of the well and was contained within the dike. Peat absorbent has been applied to the oil around the well head. The tank battery consist of (2) 100 barrel tanks inside of a dike. ID is posted at the tanks. No violations noted this date.
4673866 2002-08-12 Grading done pit filled in and smoothed out.