X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-22710

Well Details

Well ID: 34-155-22710
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1985-01-18
Unconventional:
Horizontal:
Producing: No
Violations: 3
Latitude: 41.3167842113
Longitude: -80.547874881

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1178977238 2014-03-05 I was on location to check compliance to Chief's Order 2014-43. My inspection found the well was equipped with a plunger lift unit. The valve leading to the flow line from the well was open. There was a domestic flow line coming off the 4.5" casing. The tank battery consisted of a 100 barrel production tank, a 50 barrel brine tank, and a heat, treated separator. The separator had the correct spacing. There was an identification sign posted on the separator with no identification. The dike was completely weathered and not meeting containment requirements. The flow line valves leading to and exiting the separator were open. There was a production chart inside the separator with no date. The lease road was in stable condition. Photos were taken of all the production equipment. The well was in production which was in non-compliance of Chief's order #2014-43. The well needs to be shut-in immediately. 9-9-05(A)10
-1178977238 2014-03-05 I was on location to check compliance to Chief's Order 2014-43. My inspection found the well was equipped with a plunger lift unit. The valve leading to the flow line from the well was open. There was a domestic flow line coming off the 4.5" casing. The tank battery consisted of a 100 barrel production tank, a 50 barrel brine tank, and a heat, treated separator. The separator had the correct spacing. There was an identification sign posted on the separator with no identification. The dike was completely weathered and not meeting containment requirements. The flow line valves leading to and exiting the separator were open. There was a production chart inside the separator with no date. The lease road was in stable condition. Photos were taken of all the production equipment. The well was in production which was in non-compliance of Chief's order #2014-43. The well needs to be shut-in immediately. 9-9-05(A)9
-1178977238 2014-03-05 I was on location to check compliance to Chief's Order 2014-43. My inspection found the well was equipped with a plunger lift unit. The valve leading to the flow line from the well was open. There was a domestic flow line coming off the 4.5" casing. The tank battery consisted of a 100 barrel production tank, a 50 barrel brine tank, and a heat, treated separator. The separator had the correct spacing. There was an identification sign posted on the separator with no identification. The dike was completely weathered and not meeting containment requirements. The flow line valves leading to and exiting the separator were open. There was a production chart inside the separator with no date. The lease road was in stable condition. Photos were taken of all the production equipment. The well was in production which was in non-compliance of Chief's order #2014-43. The well needs to be shut-in immediately. NONE9
-373090904 2014-03-17 My inspection found the same production chart inside the separator since my previous inspection on 3/10/2014 with double markings for production. The valve on the flow line at the well was still open. I took additional photos.
1125962112 2014-03-10 I was on location to perform a follow-up inspection to compliance notice #1178977238, which was issued in reference to Chief's Order 2014-43. My inspection found the valve on the flow line at the well open. There were open valves leading to and exiting the separator. The production chart inside the separator was changed and had a date of 3/6. I took additional photos of the production chart and the well. The well was in production which was in non-compliance of Chief's Order 2014-43. The well needs to be shut-in immediately.
1240686677 2014-04-25 I was on location to re-inspect in reference to Chief's Order 2014-43 and Compliance Notice #1178977238. My inspection found the main ball valve at the 4" Concoyl Unit open. The ball valve on the flow line at the well was open. There was a production chart inside the separator with a date of 4/15 and no year. The dike was completely weathered and not capable of meeting containment requirements. I noticed oil stained soil around the brine tank and production tank. I took photos of the well, separator, production chart and tank battery. The well was in production which was in non-compliance of Chief's Order 2014-43.
1394127941 2014-03-06 My inspection was a follow-up to compliance notice #1178977238. I took additional pictures of the production chart inside the separator as evidence that the well was in production. The well was in production which was in non-compliance of Chief's order #2014-43. The well needs to be shut-in immediately.
1398702807 2014-04-28 I was on location to re-inspect in reference to Chief's Order 2014-43 and Compliance Notice #1178977238. The same production chart from my inspection on 4/25/2014 was inside the separator; however, the movement of the chart showed production. The dike was completely weathered and not capable of meeting containment requirements. I noticed oil stained soil around the brine tank and production tank. I took photos of the well, separator, production chart and tank battery. The well was in production which was in non-compliance of Chief's Order 2014-43.
PL3632 Preliminary Restoration done information from Data Point