If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-053-20533 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":38.8453185515,"lon":-82.1615906849,"icon":""}]} |
County: | |
Municipality: | |
Operator Name: | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 1980-05-20 | |
Unconventional: | |
Horizontal: | |
Producing: No | |
Violations: 10 | |
Latitude: 38.8453185515 | |
Longitude: -82.1615906849 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
-1021405559 | 2006-02-16 | Still has V notch in pipe at tank that allow oil to run out on the ground. Size fo dike for tank inadequate. Electric line along side of the road is on the ground and on bushes. | 9-1-07 | |||
-1021405559 | 2006-02-16 | Still has V notch in pipe at tank that allow oil to run out on the ground. Size fo dike for tank inadequate. Electric line along side of the road is on the ground and on bushes. | 9-9-02 | |||
-1021405559 | 2006-02-16 | Still has V notch in pipe at tank that allow oil to run out on the ground. Size fo dike for tank inadequate. Electric line along side of the road is on the ground and on bushes. | 9-9-05(A)9 | |||
-1504022766 | 2007-09-13 | The "V" notch has been fixed and the power line at the top of the hill is off the ground. The power line is down all the way down the hill and needs to be fixed. There is a 2" cone valve leaking brine in the dike that needs to be fixed. The second tank still had the Gatorade bottle in it as a coupling. This "connection" is leaking and causing contamination in the dike. I spray painted a orange dot on all areas that are leaking in the dike. I called Herald and informed him that the work was not completed and that I marked the problem areas with paint. | ||||
-1784459902 | 2007-07-26 | Tank is still leaking brine in to the dike. Tested with High End Quantabs and the result was off the charts. Some brine is coming from the notches that are cut in the top of the plastic lines coming from the bottom of the tanks. Electric lines to the pump jack motor are on the ground and pose a serious hazard and need to be raised to a safe level. Well has a good id and is in production. | 9-10-04 | |||
-1784459902 | 2007-07-26 | Tank is still leaking brine in to the dike. Tested with High End Quantabs and the result was off the charts. Some brine is coming from the notches that are cut in the top of the plastic lines coming from the bottom of the tanks. Electric lines to the pump jack motor are on the ground and pose a serious hazard and need to be raised to a safe level. Well has a good id and is in production. | 9-1-07 | |||
-1784459902 | 2007-07-26 | Tank is still leaking brine in to the dike. Tested with High End Quantabs and the result was off the charts. Some brine is coming from the notches that are cut in the top of the plastic lines coming from the bottom of the tanks. Electric lines to the pump jack motor are on the ground and pose a serious hazard and need to be raised to a safe level. Well has a good id and is in production. | 9-9-02 | |||
-1784459902 | 2007-07-26 | Tank is still leaking brine in to the dike. Tested with High End Quantabs and the result was off the charts. Some brine is coming from the notches that are cut in the top of the plastic lines coming from the bottom of the tanks. Electric lines to the pump jack motor are on the ground and pose a serious hazard and need to be raised to a safe level. Well has a good id and is in production. | NONE[C] | |||
-1979743694 | 2004-09-10 | Overgrown with brush; power line on ground on the access road up to well; minor stuffing box leak. | ||||
-392340799 | 2007-09-24 | Leaking valve has been replaced. Both tanks have plugs in them to prevent leaks. Brine in the dike has been cleaned up. Electric line is on poles and looks good. NOV passed. | ||||
1136159758 | 2007-08-13 | Tanks are still leaking from the cut lines in the dike. There has been no change since the last inspection. | ||||
1161970978 | 2006-02-16 | FOLLOW UP TO NOV # -1021405559 Still has V notch in pipe at tank that allow oil to run out on the ground. Size fo dike for tank inadequate. Electric line along side of the road is on the ground and on bushes. | 9-1-07 | |||
1161970978 | 2006-02-16 | FOLLOW UP TO NOV # -1021405559 Still has V notch in pipe at tank that allow oil to run out on the ground. Size fo dike for tank inadequate. Electric line along side of the road is on the ground and on bushes. | 9-9-02 | |||
1161970978 | 2006-02-16 | FOLLOW UP TO NOV # -1021405559 Still has V notch in pipe at tank that allow oil to run out on the ground. Size fo dike for tank inadequate. Electric line along side of the road is on the ground and on bushes. | 9-9-05(A)9 |