If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-139-20693 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.5878043005,"lon":-82.4457617271,"icon":""}]} |
County: | |
Municipality: | |
Operator Name: | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 1999-03-17 | |
Unconventional: | |
Horizontal: | |
Producing: No | |
Violations: 2 | |
Latitude: 40.5878043005 | |
Longitude: -82.4457617271 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
-1248196648 | 2003-05-22 | Inspect well. No change. Belt on pump jack motor has broken and is disconnected. Well is currently Incapable of production. | ||||
-1394478606 | 2004-03-26 | Inspect Site. Well incapable. Electrical off. Belts disconnected. | ||||
-1691469421 | 2011-06-27 | Set cement retainer at 2464 ft. for plugging. | ||||
-2134929461 | 2006-12-21 | Inspect site site ok. Close NOV 9/30/2005. | ||||
-282255571 | 2002-10-30 | Well inspection. Slight leak of brine from stuffing box when polish rod is extended into the well. Causing ground at well head to be wetter than normal. Some erosional features down gradient of well head. Discuss with Dennis Weese. Will address situation immediately. | ||||
-61654041 | 2005-04-12 | Inspect Well. ID posted. Incapable of production. Belts for motor are disconnected. | ||||
-772467832 | 2012-07-16 | Inspect well location. Well plugged and all equipment and related debris has been removed. | ||||
1057020855 | 2003-06-30 | Inspect well. Well is capable of production and product lines are under pressure. Site "Cleanup" has occurred in some capacity. A front end loader bucket may have been scooped from well head area and replaced or covered with sand fill in the immediate vicinity of the well head. A bucket of soil/ material was dumped near the top of the downward slope covering part of a heavily oil stained area, then the bucket was back dragged to continue covering the oil stained area. The oil run off area has not been remediated or changed from when oil originally flowed over the slope. Some oil residual oil is still present in the run-off channel. The area around the well has been worked with a front end loader when the ground was wet, and subsequently has dried. The presence of oil has been covered and is not visible.
Inspected tank battery for wells 693, 694, and 689. An uncontrolled release of brine and or petroleum has occurred from these tanks or the associated piping. The release flowed around each of the tanks staining the gravel base and flowed along the access road, then crossed the access road and pooled at the base of 6 to 8 40 foot pine trees that are currently dead. Attempts have been made to cover the stained ground with pea gravel and other debris. |
||||
1266350503 | 2010-02-01 | Inspect tanks. Tank leaking brine from heater tube. Contacted operator by phone to repot problem. Follow up. Operator reported tank was drained. | 9-1-07 | |||
1776834830 | 2003-05-01 | Inspect well site. Oil and brine have accumulated in a pool in front of the pump jack and well head. The fluids have migrated off site following an erosion channel. This has caused off site damage / impact. The pump jack is coated with oil that has squirted from the stuffing box. | ||||
1801521488 | 2005-01-20 | Inspect Well with Jeff Fry. | ||||
2014362433 | 2012-04-12 | inspect location. Well plugged. Site ok. Segment of pipe remaining at location. Compliance order extended. | ||||
464809835 | 2004-10-20 | Inspect Well. Well shut in. site looks ok. | ||||
953545458 | 2003-10-22 | Inspect Site. Identification is posted. Restoration has been completed. | ||||
989329237 | 2005-09-30 | Inspect Well for Tom Tugend, with Jeff Fry. ID posted. No belts on motor and pump jack. Incapable of production. | NONE | |||
iDIAN002428 | 1999-11-04 | |||||
VER1030 | 1999-04-08 |