If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-155-24078 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.2383266104,"lon":-80.6413150425,"icon":""}]} |
County: | |
Municipality: | |
Operator Name: | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 2014-01-08 | |
Unconventional: | |
Horizontal: | |
Producing: No | |
Violations: 0 | |
Latitude: 41.2383266104 | |
Longitude: -80.6413150425 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
-1046901343 | 2014-01-09 | The installation and cementing of the conductor casing was witnessed. 159 feet of 16 inch conductor was cemented using 375 sacks of class A cement. The cement operation and well site conditions were acceptable. | ||||
-1953961091 | 2014-02-10 | A mechanical integrity test was performed on the well. 2147 psi. of pressure was placed on the tubing/casing annulus. The test passed. | ||||
-327502558 | 2014-01-11 | The blow-out preventor and surface casing were pressure tested. 640 psi. was placed on the casing. The test passed without pressure loss. | ||||
-737927110 | 2014-01-29 | The drilling rig, which was idle at the time, will be used to complete the well. All conditions on site were acceptable. | ||||
1205888233 | 2014-06-18 | A mechanical integrity test on the injection line was witnessed. A pressure of 2000 psi. was placed on the injection line. The test passed without any loss. | ||||
1277551340 | 2014-01-23 | A total of 7990 feet of 5-1/2 inch casing was cemented with 300 sacks of cement. The cement operation was acceptable. | ||||
1345933753 | 2014-01-22 | The drilling contractor was tripping out drill pipe. A total depth of 8748 feet was reached. | ||||
1390332944 | 2014-01-15 | The drilling rig was running 8-5/8 inch intermediate casing. All conditions were acceptable. | ||||
1390492700 | 2014-01-15 | Wildcat Drilling drilled a 11" well bore to a total depth of 5276' and ran 5223' of 32# 8.627" intermediate casing. Wildcat Drilling loaded the hole. Petroset broke circulation with 10 barrels and pumped 10 barrels of TSP followed by 50 barrels of Gel. The first stage they pumped 300 sacks of 50/50 pos 2% gel 10% salt 6# to the sack Gilsonite. Second stage they pumped 300sacks of 50/50 pos 2%gel 10% salt 10# to the sack of Gilsonite. Displaced with 315.5 barrels of water. Bumped plug with 650 psi. Pumped to 1300 psi. and held for 10 minutes. Good circulation throughout job. Shut cement head in for 24 hours. | ||||
1391105469 | 2014-01-30 | The drilling contractor was tripping in a tubing string with bit. The formation packer will be drilled out, using a power swivel. | ||||
1392047223 | 2014-01-10 | The installation and cementing of the surface casing was witnessed. 607 feet of 11-3/4 inch surface casing was cemented using 400 sacks of class A cement. Good cement returns were observed. The cement operation and well site conditions were acceptable. | ||||
1633772903 | 2014-01-21 | The rig was drilling on air at 8739 feet. All conditions were acceptable. | ||||
1717715625 | 2014-01-14 | The rig was drilling on air at 4848 feet. Well site conditions were acceptable. | ||||
319568348 | 2014-04-11 | A Blue Dot crew installed down hole gauges for the pressure fall-off test. There were no problems encountered. | ||||
604027105 | 2014-02-07 | An attempt was made to circulate corrosion inhibitor/fresh water mix and set the packer. The well flowed back and the job was cancelled. | ||||
717198214 | 2014-02-07 | The packer installation was witnessed. A Weatherford dual element packer was ran on 2-7/8 inch tubing. |