34-155-24078

Well Details

Well ID: 34-155-24078
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2014-01-08
Unconventional:
Horizontal:
Producing: No
Violations: 0
Latitude: 41.2383266104
Longitude: -80.6413150425

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1046901343 2014-01-09 The installation and cementing of the conductor casing was witnessed. 159 feet of 16 inch conductor was cemented using 375 sacks of class A cement. The cement operation and well site conditions were acceptable.
-1953961091 2014-02-10 A mechanical integrity test was performed on the well. 2147 psi. of pressure was placed on the tubing/casing annulus. The test passed.
-327502558 2014-01-11 The blow-out preventor and surface casing were pressure tested. 640 psi. was placed on the casing. The test passed without pressure loss.
-737927110 2014-01-29 The drilling rig, which was idle at the time, will be used to complete the well. All conditions on site were acceptable.
1205888233 2014-06-18 A mechanical integrity test on the injection line was witnessed. A pressure of 2000 psi. was placed on the injection line. The test passed without any loss.
1277551340 2014-01-23 A total of 7990 feet of 5-1/2 inch casing was cemented with 300 sacks of cement. The cement operation was acceptable.
1345933753 2014-01-22 The drilling contractor was tripping out drill pipe. A total depth of 8748 feet was reached.
1390332944 2014-01-15 The drilling rig was running 8-5/8 inch intermediate casing. All conditions were acceptable.
1390492700 2014-01-15 Wildcat Drilling drilled a 11" well bore to a total depth of 5276' and ran 5223' of 32# 8.627" intermediate casing. Wildcat Drilling loaded the hole. Petroset broke circulation with 10 barrels and pumped 10 barrels of TSP followed by 50 barrels of Gel. The first stage they pumped 300 sacks of 50/50 pos 2% gel 10% salt 6# to the sack Gilsonite. Second stage they pumped 300sacks of 50/50 pos 2%gel 10% salt 10# to the sack of Gilsonite. Displaced with 315.5 barrels of water. Bumped plug with 650 psi. Pumped to 1300 psi. and held for 10 minutes. Good circulation throughout job. Shut cement head in for 24 hours.
1391105469 2014-01-30 The drilling contractor was tripping in a tubing string with bit. The formation packer will be drilled out, using a power swivel.
1392047223 2014-01-10 The installation and cementing of the surface casing was witnessed. 607 feet of 11-3/4 inch surface casing was cemented using 400 sacks of class A cement. Good cement returns were observed. The cement operation and well site conditions were acceptable.
1633772903 2014-01-21 The rig was drilling on air at 8739 feet. All conditions were acceptable.
1717715625 2014-01-14 The rig was drilling on air at 4848 feet. Well site conditions were acceptable.
319568348 2014-04-11 A Blue Dot crew installed down hole gauges for the pressure fall-off test. There were no problems encountered.
604027105 2014-02-07 An attempt was made to circulate corrosion inhibitor/fresh water mix and set the packer. The well flowed back and the job was cancelled.
717198214 2014-02-07 The packer installation was witnessed. A Weatherford dual element packer was ran on 2-7/8 inch tubing.