Well Details

Well ID: 34-155-22650
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1985-01-11
Unconventional:
Horizontal:
Producing: No
Violations: 2
Latitude: 41.4655892451
Longitude: -80.9585758258

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1673887934 2014-02-03 My inspection found the well in production. The well was equipped with a pumping unit. The tank battery consisted of a 100 barrel production tank, concrete brine tank, and a separator. The dike met containment requirements. An identification sign was properly posted. There was a plug on the load line. The lease road was in good condition.
-1868260186 2003-05-23 Proper identification is now posted. Wellhead contamination has been removed. The old piping and sucker rods have been removed. Recommend case be resolved.
-2024647199 2007-11-08 no violations .
1048163866 2003-03-17 The identification number is incorrect and needs to be changed to 2650. There is oil contamination inside the dike from the salt water discharge line on the southwest side of the oil storage tank around the tank to the north side between the buried salt water tank and the oil storage tank. The approximate size is 8' X 20'. There is an area from the wellhead toward the north that is contaminated with oil and needs to be removed and properly disposed of. The approximate size of this area is 20' X 25'. There is also old piping and sucker rods present on the well site next to the wellhead and to the east approximately 40' that all need to be removed. The tank battery consists of one100 bbl tank, one horizontal seperator and one buried concrete salt water tank. 9-1-07
1048163866 2003-03-17 The identification number is incorrect and needs to be changed to 2650. There is oil contamination inside the dike from the salt water discharge line on the southwest side of the oil storage tank around the tank to the north side between the buried salt water tank and the oil storage tank. The approximate size is 8' X 20'. There is an area from the wellhead toward the north that is contaminated with oil and needs to be removed and properly disposed of. The approximate size of this area is 20' X 25'. There is also old piping and sucker rods present on the well site next to the wellhead and to the east approximately 40' that all need to be removed. The tank battery consists of one100 bbl tank, one horizontal seperator and one buried concrete salt water tank. 9-9-05(A)10
PL3666 Preliminary Restoration done information from Data Point