34-059-21979

Well Details

Well ID: 34-059-21979
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1976-10-02
Unconventional:
Horizontal:
Producing: No
Violations: 7
Latitude: 40.0320971587
Longitude: -81.6058816531

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1309538804 2013-05-01 Inspected site along with local inspector and it was determined that there has been no change in status of well it still remains idle and all valves at wellhead were shut on this day of our inspection.
-1452140164 2013-05-02 On the day of my inspection I meet with inspector David Ball to check the status of this well, the well still remains idle, there is a pumping unit at the well, the valves on the production line at the well head are closed. At the entry way there is a separator/ drip and (2) one hundred barrel production tanks and (1) fifty barrel steel brine tank with the I.D. posted setting inside a containment dike. The requirements to meet The Division of Oil and Gas standards will be to make the well capable of commercial production within thirty days or plugging is required within ninety days, failure to comply may result in forfeiture of bond. 9-9-02
-1452140164 2013-05-02 On the day of my inspection I meet with inspector David Ball to check the status of this well, the well still remains idle, there is a pumping unit at the well, the valves on the production line at the well head are closed. At the entry way there is a separator/ drip and (2) one hundred barrel production tanks and (1) fifty barrel steel brine tank with the I.D. posted setting inside a containment dike. The requirements to meet The Division of Oil and Gas standards will be to make the well capable of commercial production within thirty days or plugging is required within ninety days, failure to comply may result in forfeiture of bond. 9-9-05(B)
-1452140164 2013-05-02 On the day of my inspection I meet with inspector David Ball to check the status of this well, the well still remains idle, there is a pumping unit at the well, the valves on the production line at the well head are closed. At the entry way there is a separator/ drip and (2) one hundred barrel production tanks and (1) fifty barrel steel brine tank with the I.D. posted setting inside a containment dike. The requirements to meet The Division of Oil and Gas standards will be to make the well capable of commercial production within thirty days or plugging is required within ninety days, failure to comply may result in forfeiture of bond. NONE
-1452140164 2013-05-02 On the day of my inspection I meet with inspector David Ball to check the status of this well, the well still remains idle, there is a pumping unit at the well, the valves on the production line at the well head are closed. At the entry way there is a separator/ drip and (2) one hundred barrel production tanks and (1) fifty barrel steel brine tank with the I.D. posted setting inside a containment dike. The requirements to meet The Division of Oil and Gas standards will be to make the well capable of commercial production within thirty days or plugging is required within ninety days, failure to comply may result in forfeiture of bond. NONE18
-1452140164 2013-05-02 On the day of my inspection I meet with inspector David Ball to check the status of this well, the well still remains idle, there is a pumping unit at the well, the valves on the production line at the well head are closed. At the entry way there is a separator/ drip and (2) one hundred barrel production tanks and (1) fifty barrel steel brine tank with the I.D. posted setting inside a containment dike. The requirements to meet The Division of Oil and Gas standards will be to make the well capable of commercial production within thirty days or plugging is required within ninety days, failure to comply may result in forfeiture of bond. NONEC
-1659661566 2008-01-29 INSPECTION REVEALED WELL TO BE IDLE. ALL SURFACE CONNECTIONS ARE DISCONNECTED. NONE
-327026817 2003-06-04 STATUS CHECK
-731671556 2009-12-17 Inspection revealed that well is equipped with pumping unit and tubing and rods and 2-100 bbl tanks and 1-50 bbl tank in need of proper dike construction, inspected site along with supervisor Robert Stonerock.
1212505390 2008-06-03 CALLED TED HAAS, RANGE RESOURCES, INQUIRED ON P# 1979. HE HAD NO KNOWLEDGE OF NOV ON WELL. WOULD CALL ME BACK AS SOON AS HE HAD FOUND OUT SOMETHING. WELL IS STILL IDLE AND NEEDS PLUGGED OR PRODUCED.
1377011229 2013-08-20 On the day of my inspection I witnessed no change in the status of the well pryor to my last inspection.
219690321 2010-03-04 At site with company rep Nick Berlsman to discuss plug job.
344627190 2010-02-18 Inspection revealed that there has been no change in status of well it still remains idle, called company rep Mark Moody and discussed future plan for said well and he stated that he would inquire with corporate officer and get back with me with future plan for placing well into production or plug said well. NONE