If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-015-20209 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.729588,"lon":-76.569416,"icon":""}]} |
County: Bradford | |
Municipality: Burlington Township | |
Operator Name: CHIEF OIL & GAS LLC | |
Well Pad ID: 151359 | |
Farm/Lease Name: HARRIS 1H | |
First Permit Date: 2009-04-01 | |
Last Permit Date: 2009-04-01 | |
Spud Date: 2009-05-24 | |
Unconventional: Yes | |
Horizontal: Yes | |
Well Status: ACTIVE | |
Violations: 9 | |
Latitude: 41.729588 | |
Longitude: -76.569416 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
2010-3 | 151501.0 | 140.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2009-0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2010-2 | 102003.0 | 184.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2010-2 | 102003.0 | 184.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-1 | 69468.0 | 180.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-2 | 47628.0 | 184.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2012-1 | 34296.8 | 182.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2012-2 | 22647.0 | 184.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2013-1 | 21207.0 | 181.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2013-2 | 16194.0 | 184.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2014-1 | 18657.0 | 172.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2014-2 | 11785.0 | 158.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2015-02 | 802.47 | 23.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2015-01 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2015-03 | 3043.41 | 31.0 | 0.0 | 0.0 | 0.0 | 0.0 |
For data sources see[1]
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|---|---|---|---|---|---|---|---|
2010-3 | DRILLING FLUID WASTE | 134.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 | FLUID RECOVERY SERVICE FRANKLIN FACILITY | FRANKLIN | PA |
2010-3 | DRILLING FLUID WASTE | 1.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0027057 | WILLIAMSPORT SAN AUTH CENTRAL STP | WILLIAMSPORT | PA |
2010-3 | FRACING FLUID WASTE | 6.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 | SUNBURY GENERATION WASTE WATER TRMT FAC | SHAMOKIN DAM | PA |
2010-3 | FRACING FLUID WASTE | 130.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0027057 | WILLIAMSPORT SAN AUTH CENTRAL STP | WILLIAMSPORT | PA |
2010-3 | PRODUCED FLUID | 2.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 | SUNBURY GENERATION WASTE WATER TRMT FAC | SHAMOKIN DAM | PA |
2009-0 | BRINE | 2.0 | Bbl | BRINE OR INDUSTRIAL WASTE TREATMENT PLT | PA0008451 | SUNBURY GENERATION WASTE WATER TRMT FAC | SHAMOKIN DAM | PA |
2009-0 | DRILLING | 130.0 | Bbl | BRINE OR INDUSTRIAL WASTE TREATMENT PLT | PA0101508 | PA BRINE | PA | |
2010-2 | PRODUCED FLUID | 130.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 | EUREKA RESOURCES LLC WILLIAMSPORT WATER TREATMENT | WILLIAMSPORT | PA |
2010-2 | PRODUCED FLUID | 420.0 | Bbl | INJECTION DISPOSAL WELL | 34-155-23795 | PANDER #1 (SWIW #15) | NEWTON FALLS | OH |
2010-2 | PRODUCED FLUID | 614.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 | SUNBURY GENERATION WASTE WATER TRMT FAC | SHAMOKIN DAM | PA |
2010-2 | PRODUCED FLUID | 426.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123D001X | TERRAQUA RESOURCE MANAGEMENT | WILLIAMSPORT | PA |
2012-1 | PRODUCED FLUID | 299.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR HYDRAULIC FRACTURING | |||
2012-2 | PRODUCED FLUID | 55.1 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR HYDRAULIC FRACTURING | |||
2013-1 | PRODUCED FLUID | 39.5 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR HYDRAULIC FRACTURING | |||
2014-1 | PRODUCED FLUID | 58.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY | |||
2014-1 | PRODUCED FLUID | 83.0 | Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123D001X | TERRAQUA RESOURCE MANAGEMENT | WILLIAMSPORT | PA |
2014-2 | PRODUCED FLUID | 1.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY |
For data sources see[2]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
1841333 | 2009-10-29 | No Violations Noted | ||||
1849986 | 2009-12-15 | Violation(s) Noted | Silt fence need repair, silt fence not installed correctly, missing sed trap BMP (probably removed by pipeline construction crew). E&S plan not reflecting site conditions. | 577818 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | |
1849986 | 2009-12-15 | Violation(s) Noted | Silt fence need repair, silt fence not installed correctly, missing sed trap BMP (probably removed by pipeline construction crew). E&S plan not reflecting site conditions. | 577819 | 102.4INADPLN - E&S Plan not adequate | 102.4(b)(5) - plan does not reflect site conditions |
1860170 | 2010-01-07 | Violation(s) Noted | Water transfer line - released full volume directly into 2 streams | 580539 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | |
1860170 | 2010-01-07 | Violation(s) Noted | Water transfer line - released full volume directly into 2 streams | 580540 | 401CAUSEPOLL - Polluting substance(s) allowed to discharge into Waters of the Commonwealth. | |
1860170 | 2010-01-07 | Violation(s) Noted | Water transfer line - released full volume directly into 2 streams | 580541 | 402POTNLPOLL - There is a potential for polluting substance(s) reaching Waters of the Commonwealth and may require a permit. | |
1881707 | 2010-05-03 | Violation(s) Noted | Several spills found thru complainant report. Flowback from tank battery of 20 wheelie tanks manifolded together. Each tank's capacity is 21,000 gallons. See inspection report for more detail. Also found several petroleum spills on site. None of these spills were ever reported to the Department by Chief. | 586310 | 91.33POLLINC - Pollution incident was not reported to DEP. | 91.33 - Failure to report: ongoing flowback leaks from tanks, large volume flowback release from tanks, cuttings on the ground, and 7 petroleum releases to the ground. |
1881707 | 2010-05-03 | Violation(s) Noted | Several spills found thru complainant report. Flowback from tank battery of 20 wheelie tanks manifolded together. Each tank's capacity is 21,000 gallons. See inspection report for more detail. Also found several petroleum spills on site. None of these spills were ever reported to the Department by Chief. | 586311 | 402POTNLPOLL - There is a potential for polluting substance(s) reaching Waters of the Commonwealth and may require a permit. | 691.402 - potential to pollute waters of the commonwealth |
1881707 | 2010-05-03 | Violation(s) Noted | Several spills found thru complainant report. Flowback from tank battery of 20 wheelie tanks manifolded together. Each tank's capacity is 21,000 gallons. See inspection report for more detail. Also found several petroleum spills on site. None of these spills were ever reported to the Department by Chief. | 586312 | 301UNPMTIW - Industrial waste was discharged without permit. | 6018.301 |
1881707 | 2010-05-03 | Violation(s) Noted | Several spills found thru complainant report. Flowback from tank battery of 20 wheelie tanks manifolded together. Each tank's capacity is 21,000 gallons. See inspection report for more detail. Also found several petroleum spills on site. None of these spills were ever reported to the Department by Chief. | 586313 | 78.56PITCNST - Impoundment not structurally sound, impermeable, 3rd party protected, greater than 20" of seasonal high ground water table | 78.56 general - failure to contain pollutional substance in a lined pit or impermeable tank |
1884274 | 2010-05-07 | Outstanding Violations - No Viols Req'd | ||||
1893654 | 2010-06-01 | Outstanding Violations - No Viols Req'd | No new violations. | |||
1900880 | 2010-07-21 | No Violations Noted | ||||
2041632 | 2012-02-08 | No Violations Noted | ||||
2050214 | 2012-03-12 | No Violations Noted |
For data sources see[3]