If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20633 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.715352,"lon":-75.642094,"icon":""}]} |
County: Susquehanna | |
Municipality: Lenox Township | |
Operator Name: SOUTHWESTERN ENERGY PROD CO | |
Well Pad ID: 145631 | |
Farm/Lease Name: NORTH VALENTINE PRICE GU 1H | |
First Permit Date: 2011-08-31 | |
Last Permit Date: 2011-08-31 | |
Spud Date: 2011-09-06 | |
Unconventional: Yes | |
Horizontal: Yes | |
Well Status: ACTIVE | |
Violations: 4 | |
Latitude: 41.715352 | |
Longitude: -75.642094 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
2011-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2012-1 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2012-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2013-1 | 363046.0 | 127.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2013-2 | 540890.0 | 184.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2014-1 | 494613.0 | 181.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2014-2 | 332319.0 | 183.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2015-02 | 69175.0 | 28.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2015-01 | 80023.0 | 31.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2015-03 | 77725.0 | 31.0 | 0.0 | 0.0 | 0.0 | 0.0 |
For data sources see[1]
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|---|---|---|---|---|---|---|---|
2012-2 | FLOWBACK FRACTURING SAND | 19.54 | Tons | LANDFILL | 101247 | KEYSTONE SANITARY LANDFILL | DUNMORE | PA |
2013-1 | DRILL CUTTINGS | 212.6 | Tons | LANDFILL | 101247 | KEYSTONE SANITARY LANDFILL | DUNMORE | PA |
2013-1 | FLOWBACK FRACTURING SAND | 56.63 | Tons | LANDFILL | 101247 | KEYSTONE SANITARY LANDFILL | DUNMORE | PA |
2013-2 | DRILL CUTTINGS | 595.4 | Tons | LANDFILL | 101247 | KEYSTONE SANITARY LANDFILL | DUNMORE | PA |
2013-2 | PRODUCED FLUID | 966.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY | |||
2014-1 | FLOWBACK FRACTURING SAND | 1.5 | Tons | LANDFILL | THR029 | TUNNELL HILL RECLAMATION LANDFILL | NEWLEXINGTON | OH |
2014-1 | PRODUCED FLUID | 700.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY | |||
2014-2 | PRODUCED FLUID | 145.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY |
For data sources see[2]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
2005417 | 2011-09-15 | No Violations Noted | ||||
2020128 | 2011-11-16 | No Violations Noted | Desoto Rig 9. Follow up inspection as result of nearby water supply complaint. Currently at depth = 12784'. Drilling with SOBM. TD proposed = 13249'. Drillers log on site and up to date. Should be running 5 1.2" prod casing this weekend. And then skidding to 5H well. Drilled tophole on air. Drillers log shows conditions wet at 296'. Also Damp hole at 1040. Cement reports indicate good returns on cement for surface and intermediate casing strings. 20" set at 80', 13 3/8" set at 648', and 9 5/8" set at 1628'. | |||
2126838 | 2012-12-18 | No Violations Noted | During the inspection I met with Tyler Parsons, Lead Flowhand of Rodï¾’s Production Services. He informed me flowback operations commenced on 12/11/12 and thus far (5,400) barrels of flowback fluid has been filtered. Currently, flowback is in progress, but the filter system is not is in use. The filtration equipment has been supplied by Tetra Technologies Inc.
I used an an Extech, ExStik (2) pH, Conductivity, Salinty and TDS meter to field screen several areas of ponded water on the secondary containment liner, the surface of the ground on the Well Pad and off the Well Pad. The highest conductivity reading I recorded was (2) milliSiemens/cm behind the frac tanks used as part of the flowback filtration. All other conductivity readings were below (1,000) microSiemens/cm. I observed some rips and tears in the liner in some areas, mainly near where the alternative waste management practice took place, some petroleum like sheens and (1) light tower that did not have a drip pan/catchment basin under it. I departed from the site at 12:50. |
|||
2179804 | 2013-06-20 | Violation(s) Noted | This well was selected as according to Department records it is the most recently completed and stimulated well on this location. Spill of Production Fluid onto well pad and access road with runoff entering 2 separate wetland areas. | 671874 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Failed to properly manage residual waste. |
2179804 | 2013-06-20 | Violation(s) Noted | This well was selected as according to Department records it is the most recently completed and stimulated well on this location. Spill of Production Fluid onto well pad and access road with runoff entering 2 separate wetland areas. | 671875 | 78.57 - Failure to post pit approval number | Violation of 78.57(a). Failed to store production fluid in a pit or tank. |
2179804 | 2013-06-20 | Violation(s) Noted | This well was selected as according to Department records it is the most recently completed and stimulated well on this location. Spill of Production Fluid onto well pad and access road with runoff entering 2 separate wetland areas. | 671876 | 401 CSL - Discharge of pollultional material to waters of Commonwealth. | Allowed production fluid to enter a wetland. Wetlands are considered waters of the Commonwealth. |
2179804 | 2013-06-20 | Violation(s) Noted | This well was selected as according to Department records it is the most recently completed and stimulated well on this location. Spill of Production Fluid onto well pad and access road with runoff entering 2 separate wetland areas. | 671877 | 91.34A - Failure to take all necessary measures to prevent spill. Inadequate diking, potential pollution | Failed to take all necessary measures to prevent pollutionof waters of the Commonwealth, through accident, carelessness or maliciousness. |
For data sources see[3]