If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-129-28639 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.50838,"lon":-79.559211,"icon":""}]} |
County: Westmoreland | |
Municipality: Washington Township | |
Operator Name: CNX GAS CO LLC | |
Well Pad ID: 148391 | |
Farm/Lease Name: GAUT 4B | |
First Permit Date: 2011-07-05 | |
Last Permit Date: 2011-10-04 | |
Spud Date: 2011-08-09 | |
Unconventional: Yes | |
Horizontal: Yes | |
Well Status: ACTIVE | |
Violations: 0 | |
Latitude: 40.50838 | |
Longitude: -79.559211 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
2011-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2012-1 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2012-2 | 619685.0 | 175.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2013-1 | 358111.0 | 181.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2013-2 | 266623.06 | 184.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2014-1 | 255815.89 | 181.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2014-2 | 177635.56 | 184.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2015-02 | 20995.41 | 28.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2015-01 | 20011.29 | 31.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2015-03 | 25279.79 | 31.0 | 0.0 | 0.0 | 0.0 | 0.0 |
For data sources see[1]
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|---|---|---|---|---|---|---|---|
2011-2 | PRODUCED FLUID | 550.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 250050885 | SOIL REMEDIATION INC. (SRI) | LOWELLVILLE | OH |
2012-1 | DRILL CUTTINGS | 1.0 | Tons | LANDFILL | 100280 | VALLEY LANDFILL | IRWIN | PA |
2012-1 | DRILLING FLUID WASTE | 239.75 | Bbl | LANDFILL | 250050885 | SOIL REMEDIATION INC. (SRI) | LOWELLVILLE | OH |
2012-1 | DRILLING FLUID WASTE | 432.85 | Bbl | LANDFILL | 100280 | VALLEY LANDFILL | IRWIN | PA |
2012-2 | DRILL CUTTINGS | 248.38 | Tons | LANDFILL | 100434 | EVERGREEN LANDFILL | BLAIRSVILLE | PA |
2012-2 | FRACING FLUID WASTE | 10.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR HYDRAULIC FRACTURING | |||
2012-2 | PRODUCED FLUID | 889.27 | Bbl | INJECTION DISPOSAL WELL | 34-155-23584 | KOONTZ #1 DISPOSAL WELL | WARREN | OH |
2012-2 | PRODUCED FLUID | 511.14 | Bbl | INJECTION DISPOSAL WELL | 34-007-22038 | PAROBEK #2 (SWIW #12) | OH | |
2012-2 | PRODUCED FLUID | 154.75 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR HYDRAULIC FRACTURING | |||
2013-1 | PRODUCED FLUID | 1.0 | Bbl | INJECTION DISPOSAL WELL | 34-155-22403 | ANNAROCK D-1 | FOWLER | OH |
2013-1 | PRODUCED FLUID | 1.0 | Bbl | INJECTION DISPOSAL WELL | 34-013-20609 | BUCKEYE UIC BARNESVILLE #1 (SWIW#2) | BARNESVILLE | OH |
2013-1 | PRODUCED FLUID | 205.92 | Bbl | INJECTION DISPOSAL WELL | 34-155-21438 | KLEESE #1 (SWIW #18) | VIENNA | OH |
2013-1 | PRODUCED FLUID | 120.0 | Bbl | INJECTION DISPOSAL WELL | 34-155-23759 | KLEESE #5 (SWIW #25) | TRUMBULL | OH |
2013-1 | PRODUCED FLUID | 511.78 | Bbl | INJECTION DISPOSAL WELL | 34-155-23584 | KOONTZ #1 DISPOSAL WELL | WARREN | OH |
2013-1 | PRODUCED FLUID | 1.0 | Bbl | INJECTION DISPOSAL WELL | 34-167-23862 | NICHOLS #1 (SWIW #13) [HECKMAN WATER RES(CVR)INC] | BELPRE | OH |
2013-1 | PRODUCED FLUID | 517.14 | Bbl | INJECTION DISPOSAL WELL | 34-007-22038 | PAROBEK #2 (SWIW #12) | OH | |
2013-1 | PRODUCED FLUID | 28.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR HYDRAULIC FRACTURING | |||
2013-2 | FRACING FLUID WASTE | 67.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY | |||
2013-2 | PRODUCED FLUID | 1.0 | Bbl | INJECTION DISPOSAL WELL | 34-013-20609 | BUCKEYE UIC BARNESVILLE #1 (SWIW#2) | BARNESVILLE | OH |
2013-2 | PRODUCED FLUID | 607.41 | Bbl | INJECTION DISPOSAL WELL | 34-119-28776 | GOFF #1 (SWIW #27) | NORWICH | OH |
2013-2 | PRODUCED FLUID | 100.62 | Bbl | INJECTION DISPOSAL WELL | 34-155-21438 | KLEESE #1 (SWIW #18) | VIENNA | OH |
2013-2 | PRODUCED FLUID | 113.49 | Bbl | INJECTION DISPOSAL WELL | 34-155-23732 | KLEESE #4 (SWIW #24) | VIENNA | OH |
2013-2 | PRODUCED FLUID | 288.9 | Bbl | INJECTION DISPOSAL WELL | 34-155-23759 | KLEESE #5 (SWIW #25) | TRUMBULL | OH |
2013-2 | PRODUCED FLUID | 370.61 | Bbl | INJECTION DISPOSAL WELL | 155-23223 | NATALE #2 (SWIW #29) | VIENNA | OH |
2013-2 | PRODUCED FLUID | 107.64 | Bbl | INJECTION DISPOSAL WELL | 34-167-23862 | NICHOLS #1 (SWIW #13) [HECKMAN WATER RES(CVR)INC] | BELPRE | OH |
2013-2 | PRODUCED FLUID | 38.99 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY | |||
2013-2 | PRODUCED FLUID | 16.66 | Bbl | INJECTION DISPOSAL WELL | 34-155-21893 | WOLF #1 DISP WELL | NEWTON FALLS | OH |
2013-2 | PRODUCED FLUID | 16.67 | Bbl | INJECTION DISPOSAL WELL | 34-155-21894 | WOLF #2 DISPOSAL WELL | NEWTON FALLS | OH |
2013-2 | PRODUCED FLUID | 16.67 | Bbl | INJECTION DISPOSAL WELL | 34-155-23203 | WOLF #4 DISPOSAL WELL | NEWTON FALLS | OH |
2014-1 | PRODUCED FLUID | 99.23 | Bbl | INJECTION DISPOSAL WELL | 34-013-20609 | BUCKEYE UIC BARNESVILLE #1 (SWIW#2) | BARNESVILLE | OH |
2014-1 | PRODUCED FLUID | 352.17 | Bbl | INJECTION DISPOSAL WELL | 34-155-21438 | KLEESE #1 (SWIW #18) | VIENNA | OH |
2014-1 | PRODUCED FLUID | 132.21 | Bbl | INJECTION DISPOSAL WELL | 34-155-21447 | KLEESE #2 (SWIW #19) | VIENNA | OH |
2014-1 | PRODUCED FLUID | 114.66 | Bbl | INJECTION DISPOSAL WELL | 34-155-23732 | KLEESE #4 (SWIW #24) | VIENNA | OH |
2014-1 | PRODUCED FLUID | 589.68 | Bbl | INJECTION DISPOSAL WELL | 34-155-23223 | NATALE #2 (SWIW #29) | VIENNA | OH |
2014-1 | PRODUCED FLUID | 2.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY | |||
2014-2 | PRODUCED FLUID | 1.0 | Bbl | INJECTION DISPOSAL WELL | 34-013-20609 | BUCKEYE UIC BARNESVILLE #1 (SWIW#2) | BARNESVILLE | OH |
2014-2 | PRODUCED FLUID | 28.08 | Bbl | INJECTION DISPOSAL WELL | 34-119-28776 | GOFF #1 (SWIW #27) | NORWICH | OH |
2014-2 | PRODUCED FLUID | 1.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY |
For data sources see[2]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
2004647 | 2011-09-19 | No Violations Noted | Cementing 13 3/8" casing at time of inspection. Closed loop system being utilized. Pit lined and freeboard maintained. | |||
2010299 | 2011-10-07 | No Violations Noted | Waiting on rig to commence lateral drilling. Pit lined and freeboard maintained. Inspection conducted w/OGI S. Banks. | |||
2013348 | 2011-10-20 | No Violations Noted | Waiting on rig to commence lateral drilling. Pit lined and freeboard maintained. Inspection conducted w/OGI S. Banks. | |||
2014628 | 2011-10-28 | No Violations Noted | Drilling was not ongoing at the time of the inspection. A small pit had been constructed onsite and it appeared to contain drill fluids. The pit was properly lined and it had more than the required two feet of lined freeboard. All E&S controls had been installed as outlined in the E&S plan. The disturbed area had been temporarily stabilized. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site. | |||
2055814 | 2012-04-02 | No Violations Noted | Inspection in response to a spill on Friday March 30 at approximately 1:30 pm EST. The operator notified the Department within the ICP protocol and the Department was informed at the time of the call that the spill was on containment. While disassembling the rig the spill originated from a pipe between mud pits and a shaker skid. At the time of the spill a CPX Environmental truck was onsite and was immediately ordered by the operator to clean up the spill. | |||
2076916 | 2012-06-18 | No Violations Noted | At the time of inspection the well was drilled and in the beginning phases of stimulation. No accelerated erosion and sedimentation observed in relation to the well pad area or access road. The E&S plan was onsite, the BMPs were properly implemented and maintained. The associated water impoundments appeared to be in sound condition with the required 2 feet of freeboard. The Department suggest the Operator continue to monitor the site on a weekly basis and after significant precipitation events to ensure E&S remains at a minimum. | |||
2092866 | 2012-08-20 | No Violations Noted | At the time of inspection the well was drilled and stimulated and being actively equipped for production. No accelerated erosion and sedimentation observed in relation to the well pad area or access road. The E&S plan was onsite, the BMPs were properly implemented and maintained. The associated water impoundments appeared to be in sound condition with the required 2 feet of freeboard. The Department suggest the Operator continue to monitor the site on a weekly basis and after significant precipitation events to ensure E&S remains at a minimum. | |||
2101728 | 2012-09-20 | No Violations Noted | At the time of inspection the well appeared to be drilled and the Operator was actively working to equip the well for production. The well apparatus, brine tanks and heating units appear to be in sounds working condition. At the time of inspection the Erosion and Sedimentation plan was onsite and appeared to be implemented. All BMPs were installed and functionally properly. The Department suggest the Operator continue to monitor the site weekly and after significant precipitation event to ensure the stability of the site in maintained. | |||
2108700 | 2012-10-17 | No Violations Noted | At the time of inspection the drill rig was onsite and on containment. During the inspection the Operator indicated that the 4G was the well actively being drilled, at this time the 4B well was drilled and equipped for production. The associated well apparatus and brine tanks located appear to be in sound condition. During the inspection the Department walked the perimeter and inspected the associated spring and seeps down gradient from the well pad area, no observation of contaminate at the time of inspection. The Erosion and Sedimentation plan was onsite and appeared to be implemented. All BMPs were installed and functionally properly. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation event to ensure the stability of the site in maintained. | |||
2110424 | 2012-10-16 | No Violations Noted | Well operating and properly identified.
Well equipped with production unit and produced fluids tanks. Well site on pad where additional wells being drilled. |
|||
2115661 | 2012-11-14 | No Violations Noted | no violations noted | |||
2116152 | 2012-11-13 | No Violations Noted | Well operating and properly identified.
Well equipped with production unit and produced fluids tanks. Well site on pad where additional wells being drilled. |
|||
2127479 | 2013-01-03 | No Violations Noted | At the time of inspection the well appears to be drilled and equipped for production. The associated well apparatus, brine tanks, and production heaters appear to be in sound condition. The Erosion and Sedimentation plan was onsite and appeared to be implemented. All BMPs were installed and functionally properly. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation event to ensure the stability of the site in maintained. | |||
2232488 | 2013-12-30 | No Violations Noted | At the time of inspection the well appears to be plugged while the Operator prepares the site to drill additional wells. The Erosion and Sedimentation plan was onsite and appeared to be implemented. All BMPs were installed and functionally properly. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation event to ensure the stability of the site in maintained. | |||
2244027 | 2014-02-10 | No Violations Noted | At the time of inspection the well appears to be in production. The Erosion and Sedimentation plan was onsite and appeared to be implemented. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation event to ensure the stability of the site in maintained. | |||
2250122 | 2014-02-25 | No Violations Noted | Well operating and properly identified.
Well equipped with production unit and produced fluids tanks. Well on site where additional wells, three (3), waiting on frac.
|
|||
2363135 | 2015-04-21 | No Violations Noted | At the time of inspection the well appears to be in production. The Erosion and Sedimentation plan was onsite and appeared to be implemented. The Department suggests the Operator continue to monitor the site weekly and after significant precipitation event to ensure the stability of the site in maintained. | |||
2368805 | 2015-05-11 | No Violations Noted | Well operating and properly identified. Well equipped with production unit (separation |
For data sources see[3]