Well ID: 37-131-20037 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.639313,"lon":-75.973297,"icon":""}]} |
County: Wyoming | |
Municipality: Washington Township | |
Operator Name: CHESAPEAKE APPALACHIA LLC | |
Well Pad ID: 148860 | |
Farm/Lease Name: MCGRAW 2H | |
First Permit Date: 2010-05-12 | |
Last Permit Date: 2010-05-12 | |
Spud Date: 2010-08-24 | |
Unconventional: Yes | |
Horizontal: Yes | |
Well Status: ACTIVE | |
Violations: 6 | |
Latitude: 41.639313 | |
Longitude: -75.973297 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
2010-3 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2010-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2010-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-1 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2011-2 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2012-1 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2012-2 | 827205.0 | 93.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2013-1 | 2009095.0 | 181.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2013-2 | 1633497.0 | 184.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2014-1 | 981448.0 | 142.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2014-2 | 757033.0 | 109.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2015-02 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2015-01 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
2015-03 | 143774.0 | 20.0 | 0.0 | 0.0 | 0.0 | 0.0 |
For data sources see[1]
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|---|---|---|---|---|---|---|---|
2012-1 | PRODUCED FLUID | 314.5 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR HYDRAULIC FRACTURING | |||
2012-2 | PRODUCED FLUID | 55.0 | Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 | EUREKA RESOURCES LLC WILLIAMSPORT WATER TREATMENT | WILLIAMSPORT | PA |
2012-2 | PRODUCED FLUID | 726.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR HYDRAULIC FRACTURING | |||
2013-1 | PRODUCED FLUID | 415.83 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE FOR HYDRAULIC FRACTURING | |||
2013-2 | PRODUCED FLUID | 367.0 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY | |||
2014-1 | DRILLING FLUID WASTE | 100.0 | Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC008 | SHARER TEMP CENTRALIZED FLUIDS PROCESSING FACILITY | PA | |
2014-1 | FRACING FLUID WASTE | 30.0 | Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC008 | SHARER TEMP CENTRALIZED FLUIDS PROCESSING FACILITY | PA | |
2014-1 | PRODUCED FLUID | 206.87 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY | |||
2014-2 | PRODUCED FLUID | 146.17 | Bbl | REUSE OTHER THAN ROAD SPREADING | REUSE WITHOUT PROCESSING AT A PERMITTED FACILITY | |||
2014-2 | PRODUCED FLUID | 20.0 | Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC008 | SHARER TEMP CENTRALIZED FLUIDS PROCESSING FACILITY | PA |
For data sources see[2]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
1922616 | 2010-10-25 | No Violations Noted | Rigging down to move to McGraw 5H | |||
1930322 | 2010-11-23 | Violation(s) Noted | Onsite visit with DEP Geologist (Eric Rooney) and DEP WQS (Ryan Klemish). Followup inpsection of possible stray gas in cellar. Lower elbow on the 2" vent line of the 13 3/8" annulus had bubbles migrating out of joint. Small intermitent bubbles seen every 10 sec. Approx 6" of water in cellar at time of inspection. Asked DEP rep to use flir camera to detect any gas that may be present as I wasn't sure if bubbling from elbow was gas migration or plumbing problem. Also, Gauge on 13 3/8 showing 0 psi, however vavle closed during time of inspection and possible loose elbow. Talked with completions supervisor Nick Pottmeyer stating they would go out and tighten up fittings, open the vavle and monitor for any pressure buildup. Also asked Mr. Pottmeyer to replace the guage on the string with one with smaller graduations to detect any gas that may be present. | 601700 | 207B - Failure to case and cement to prevent migrations into fresh groundwater | 78.81(a)(2)&(3) |
1930322 | 2010-11-23 | Violation(s) Noted | Onsite visit with DEP Geologist (Eric Rooney) and DEP WQS (Ryan Klemish). Followup inpsection of possible stray gas in cellar. Lower elbow on the 2" vent line of the 13 3/8" annulus had bubbles migrating out of joint. Small intermitent bubbles seen every 10 sec. Approx 6" of water in cellar at time of inspection. Asked DEP rep to use flir camera to detect any gas that may be present as I wasn't sure if bubbling from elbow was gas migration or plumbing problem. Also, Gauge on 13 3/8 showing 0 psi, however vavle closed during time of inspection and possible loose elbow. Talked with completions supervisor Nick Pottmeyer stating they would go out and tighten up fittings, open the vavle and monitor for any pressure buildup. Also asked Mr. Pottmeyer to replace the guage on the string with one with smaller graduations to detect any gas that may be present. | 601701 | 78.86 - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days | |
1931929 | 2010-11-30 | Violation(s) Noted | Follow-up of loose elbow on 2" vent line of 13 3/8". Water drained from cellar. Gauges were replaced with those of smaller graduations on casing strings. 300PSI on production string. | 600760 | 207B - Failure to case and cement to prevent migrations into fresh groundwater | 78.81(a)(2)&(3) |
1931929 | 2010-11-30 | Violation(s) Noted | Follow-up of loose elbow on 2" vent line of 13 3/8". Water drained from cellar. Gauges were replaced with those of smaller graduations on casing strings. 300PSI on production string. | 600761 | 78.86 - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days | |
1931939 | 2010-12-03 | Violation(s) Noted | All valves were open and that there was no pressure on any of the gauges (including the production string). I also noted that there was a brass vented nipple installed on the 2" vent line that appeared to be on the outside of the 13 3/8" annulus. | 600762 | 207B - Failure to case and cement to prevent migrations into fresh groundwater | 78.81(a)(2)&(3) |
1931939 | 2010-12-03 | Violation(s) Noted | All valves were open and that there was no pressure on any of the gauges (including the production string). I also noted that there was a brass vented nipple installed on the 2" vent line that appeared to be on the outside of the 13 3/8" annulus. | 600763 | 78.86 - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days | |
1939058 | 2010-12-22 | No Violations Noted | Reading at wellhead measured 50% methane on vent of 13 3/8". During time of inspection noted that pressure guages were removed from the wellhead. | |||
1944427 | 2011-01-04 | No Violations Noted | Preparing location for fract ops | |||
1950451 | 2011-02-16 | No Violations Noted | ||||
1955249 | 2011-01-24 | No Violations Noted | Checked well. Head being heated. No activity. 13 3/8" being vented. | |||
1966044 | 2011-04-07 | No Violations Noted | Laying down mats and liner to prepare for spudding of 5H | |||
1985334 | 2011-06-30 | No Violations Noted | 200# gauge on surface. 0 psi. Contacted Nick Pottmeyer requesting smaller gauge (50#) on surface casing string. | |||
1987623 | 2011-07-13 | No Violations Noted | 13 3/8 gauges replaced wth 50# as requested. All other gauges 100# | |||
2004017 | 2011-09-19 | No Violations Noted | ||||
2062439 | 2012-03-15 | No Violations Noted | cellar is dug out, no water. 9 5/8" X 13 3/8" annulus vented. Checked with gas meter, no gas. | |||
2120690 | 2012-09-13 | No Violations Noted | Well fract. 2 seperators, 2 tanks. 8 Brine water tanks, 11 fresh water tanks on location
13 X 9 - -0.6735 psi. Vented to atmosphere (70% spike combustible gas, 68% hold utilizing MSA 60) 9 X 5 - -2.4680 psi (not vented) 5 1/2 - 29.634 psi |
|||
2133552 | 2013-01-15 | No Violations Noted | Producing well. No water in cellar.
tbg = 2749.9 psi 5 1/2" csg = 11.1 psi 5 1/2 x 9 5/8" annulus = 0.94 psi 9 5/8 x 13 3/8" annulus = 2.28 psi Also on pad, 5H is producing and 1 empty cellar. |
|||
2248241 | 2014-02-25 | No Violations Noted | Producing well. Cellar empty w/ a little snow.
Tbg = 1205.9 psi 5 1/2" csg = 12.9 psi 5 X 9" annulus = 0.28 psi 9 X 13" annulus = 7.1 psi |
|||
2337920 | 2015-01-20 | No Violations Noted | ||||
2348623 | 2015-02-18 | No Violations Noted | Chesapeake was in the process of breaking down secondary containment and washing rig mats. I recorded a conductivity reading of (3.59) milliSiemens/cm in water on containment on the western side of the pad near the cut slope. A vacuum truck operator was in the process of removing water on containment nearby area where the elevated conductivity was recorded. I pointed out to him the where the water with the elevated conductivity was. He claimed he would remove all of the water on containment. I recorded (3.62) milliSiemens/cm conductivity in water on the pad surface next to a heating unit and frac tank used to contain water to wash the rig mats. Mr. Wilkes informed that the water with the elevated conductivity readings off containment will be removed via and on-site vacuum truck. | |||
2349427 | 2015-02-26 | No Violations Noted | Chesapeake was in the process of breaking down secondary containment | |||
2349574 | 2015-03-05 | No Violations Noted | This administrative inspection has been created to document Chesapeake | |||
2349622 | 2015-03-06 | No Violations Noted | Chesapeake was in the process of attempting to return the McGraw 2H and McGraw 5H wells into production. Mr. Krut contacted me on 3-5-15 regarding the removal of all of the secondary containment used for hydraulic fracturing operations. The containment was completely removed from the site on 3-4-15. It has taken several weeks to remove the containment from the site due to the weather | |||
2359214 | 2015-04-08 | No Violations Noted | This administrative inspection has been created to document Chesapeake |
For data sources see[3]