X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-22161

Well Details

Well ID: 34-035-22161
Loading map...
County: Cuyahoga
Municipality:
Operator Name: OHIO VALLEY ENERGY SYSTEM CORP
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2010-07-23
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.5019772
Longitude: -81.45685928

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2011-0 19595.0 0.0
2012-0 24053.0 30.0
2013-0 29173.0 0.0
2014-0 18164.0 365.0 89.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
-1069082899 2010-07-27 Drilling at 2950' no violations.
1170344768 2010-07-29 TD reached and running 4.5 casing rigging up to cement casing.
-1192111588 2010-07-26 drilling at 2750' no violation.
1282586478 2010-07-28 Mrs. Veronica Gallo 440-446-0114 called to complain that they are drilling to close to homes at 31371 Cedar Road also she want to make sure the water table is protected . I arrived at site used GPS Checked spacing to home which is due south of well approximately 120'.

Checked casing program for what casing was set 72' of 11.75 conductor cemented on 7-23-10 no problem cementing,85/8 casing cemented on 7-23-10 no problems with cementing.

Phone to Mrs. Gallou informed her that the well meets spacing and no problems encounter while cementing of the conductor and surface casing.  

Case#10-007 Case closed:

1322771487 2011-12-01 Received complaint from resident 7 doors away of petroleum odor in water when opening spigot on outside of house. Scanned area with gas meter and obtained following readings. O2- 20.6/ LEL - 0/ H2S-0/CH4IR/ CO - 0. Company checked well pressure prior to 12:00 Noon and recorder 1 Lb pressure.
1323186307 2011-12-02 Received notification from Norburt Lowder on 12/01/2011 of complaint of petroleum smell coming from outside water spigot when it is turned on. Residence is located at 31107 Cedar Road, Mayfield Heights, Ohio. Residence is located West of the oil and gas well, #34-135-2-2161-00-00. Well and tank battery were inspected, slight gas odor in air detected by smell when entering inside well head area. Used gas meter at waist level and around connections and fittings. The readings from the meter were as follows: O2-0/LEL-0/H2S-0/CH4IR/CO-0. Well head area and tank battery were inspected by the inspectors on site. Well is in compliance with 1501:9-9-05
1351660189 2010-11-23
-1590005469 2010-07-22 The drilling contractor was rigging up on the location. MRI 2 Norburt Lowder was on location, also. Conditions were acceptable.
-2008522404 2010-07-24 BOP test passed
-2013994434 2014-08-18 I inspected this producing unit as part of routine inspection activity. The well was completed in 07/28/2010. The unit is producing and production reports are current. The producing unit is accessed via a dedicated, gravel-paved access road which extends north from the terminus of the current residential driveway. The access road is level, and well drained with no signs of erosional deficits. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger-lift system and aboveground storage tank (AST) battery in separate board-on-board enclosures. The valve fittings, connections, and other production appurtenances appear to be well maintained and are free from signs of leakage or other problems. The battery is comprised of 1 steel 100-barrel production tank, 1 25-barrel poly brine tank, and separator unit. Spacing from well to battery, and spacing of elements within the battery meet regulations. The load-outs are bull-plugged. There is secondary containment at the battery and the interior areas are dry. I did not observe any signs or evidence of leakage, spills, or problems. Unit identification placards are present at both the battery and wellhead and are in good condition. I observed no issues or problems requiring attention at the time of my inspection.
-224743257 2010-07-23 Conductor cement operation was witnessed. The cement operation and site conditions were acceptable.
-418415170 2010-07-26 Drilling on fluid at 1976' no gas encountered in oriskany top at 1946'
-504755703 2010-07-22 Rig moving onto site.
633639835 2010-08-20 Crew working on site fencing around tank battery and grading site out.
-962128036 2010-07-23 Surface casing was cemented. Cement operation and site conditions were satisfactory.
-99213477 2010-07-20 Location made, orange fencing up around site perimeter, and silt fencing up per permit conditions.

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 