X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-22090

Well Details

Well ID: 34-035-22090
Loading map...
County: Cuyahoga
Municipality:
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2008-12-30
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.45023608
Longitude: -81.46107172

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2009-0 4646.0 322.0
2010-0 5088.0 312.0
2011-0 3274.0 323.0
2012-0 2367.0 105.0
2013-0 1475.0 126.0
2014-0 1231.0 365.0 138.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
100676200 2009-02-05 site visit found company dealing with issue truck drive backed into well head bent casing now company is dealing with trying to straighten casing. No violation to company
-1224416880 2014-08-18 I inspected this producing unit as part of routine inspection activity. The well was completed in 01/08/2009. The unit is producing and production reports are current. The producing unit is accessed via a dedicated, gravel-paved access road which extends east from the terminus of the current residential driveway. The access road is level, and well drained with no signs of erosional deficits. Elements of the well consist of a production wellhead with standard valve assembly and pump jack system and aboveground storage tank (AST) battery in separate board-on-board enclosures. I observed oily impact from leaking stuffing box fitting around the base of the wellhead. I did not observe any other problems at the wellhead. The battery is comprised of 1 steel 100-barrel production tank, 1 50-barrel steel brine tank, and separator unit. Spacing from well to battery, and spacing of elements within the battery meet regulations. The load-outs are bull-plugged. There is secondary containment at the battery and the interior areas are dry. I did not observe any signs or evidence of leakage, spills, or problems. Unit identification placards are present at both the battery and wellhead and are in good condition. I contacted Bass Energy about the need to mitigate the oily impact around the wellhead and perform maintenance on the leaking stuffing box.
1236187728 2009-02-06 on site checked for violation none found. Company has been working on casing because a truck driver backed into casing and bent it company had straighten casing and rods well is ready to be put on line.
1816568852 2009-01-07 drilling at 3500' no violation
-923151374 2009-11-12 no violation.
-955924718 2009-01-05 Drilling at 2370' no violation

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 