X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-019-22230

Well Details

Well ID: 34-019-22230
Loading map...
County: Carroll
Municipality:
Operator Name: CHESAPEAKE EXPLORATION LLC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2012-12-23
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 40.49779315
Longitude: -81.07939332

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2013-12 112140.0 6729.0
2013-6 18587.0 540.0
2013-9 139532.0 11433.0
2014-1 97854.0 82.0 5583.0 82.0
2014-4 15246.0 31.0 1143.0 31.0
2014-2 96931.0 88.0 4484.0 88.0
2014-3 81575.0 91.0 3512.0 91.0
2015-1 51414.0 89.0 4056.0 89.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1356365406 2012-12-24 I was on site to witness the cementing of the 13 3/8 casing. My inspection revealed that Patterson Rig# 328 has drilled a 17.5 hole to a total depth of 605'. They ran 589' of 13 3/8 casing (54.5 pound per foot) and installed six bowspring centralizers on joints 1,2,3,6,9,12. O-TEX cemented the casing with 540 sacks of Class H cement with 2% CaCl ; .27% Cello-Flake; and 4/10% C-41P. They pumped 115.41 barrels of cement slurry with a density of 15.6 pounds per gallon, 1.2 yield cubic feet per sack, and 5.25 gallons of mix water per sack. They displaced the plug with 84 barrels of water and bumped the plug at 11:14 am with 275 PSI. There was good circulation throughout the job and 24 barrels of cement was circulated to surface. They conducted the casing test at 1100 PSI for 5 minutes and the casing test approved. Inspection of the well site revealed no violations at this time. Note: Drilling rig had trouble with pumps being frozen and steel pits being filled to maximum capacity. The drilling rig had to wait on a roll off tank before O-TEX could conduct the cement job.
1356590650 2012-12-26 I was on site to witness the cementing of the 9 5/8 intermediate casing. My inspection revealed that Patterson Rig # 328 has drilled a 12 1/4 hole to a total depth of 2240'. They ran 2222' of (40# per foot) 9 5/8 casing and installed 15 bowspring centralizers on joints 1,2,3,6,9,12,15,18,21,24,27,30,33,36,39. O-TEX cemented the casing with 790 sacks of Class H cement with 10% NaCl; .27% Cello-Flake; 4/10% C-41P (powder defoamer); 1/10% C35 (dispersant). The cement had a density of 15.6 pounds per gallon, a yield of 1.24 cubic feet per sack, and they used 5.48 gallons per sack of mix water. O-TEX pumped 162 barrels of freshwater to displace the plug. There was good circulation throughout the job and 33 barrels of cement was circulated to surface. They landed the plug at 7:26pm with 960 PSI and went straight into the casing test with 1470 PSI. Casing test was conducted for 5 minutes at 1470 PSI and the test was approved. My inspection of the well site revealed no violations at this time.
-225703457 2013-01-03 I inspected this drill site on 1/3/2013. Patterson Drilling's Rig # 328 was found to be drilling at 8978' during the curve section of the hole. Hole size was 8.75. All operations observed were in compliance.
-474897550 2014-04-08 I inspected the well site and found the well head to be constructed with a Christmas tree valve and piping. There are six wells at this site. The condensate tanks and piping runs were all intact with no leaks. The spray lined steel containment around the condensate tanks had rain water in it with no visible contamination. The diesel power unit was found to have excess oil in the spill containment under the engine. The pre-heater unit had no visible issues. While I was finishing my inspection, the contractor was there to clean up the oil under the diesel engine. No oil reached the ground. The lease road is stable condition and the site is well secured with two locked gates. No violations were found.

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 
  2. "Ohio Department of Natural Resources RBDMS". [2]. 2015-06-19. Retrieved 2015-06-20.