If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-127-25412 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.74393331,"lon":-82.38062443,"icon":""}]} |
County: Perry | |
Municipality: | |
Operator Name: BARCLAY PETROLEUM INC | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 1981-12-01 | |
Unconventional: No | |
Configuration: Vertical | |
Well Status: Final Restoration | |
Violations: 0 | |
Latitude: 39.74393331 | |
Longitude: -82.38062443 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
1985-0 | 792.0 | 317.0 | ||||
1988-0 | 260.0 | 77.0 | ||||
1989-0 | 146.0 | 157.0 | ||||
1990-0 | 0.0 | 236.0 | ||||
1991-0 | 0.0 | 315.0 | ||||
1992-0 | 0.0 | 149.0 | ||||
1993-0 | 0.0 | 77.0 | ||||
1994-0 | 0.0 | 72.0 | ||||
1995-0 | 0.0 | 74.0 | ||||
1996-0 | 0.0 | 72.0 | ||||
1997-0 | 0.0 | 73.0 | ||||
1998-0 | 0.0 | 74.0 | ||||
1999-0 | 0.0 | 71.0 | ||||
2000-0 | 0.0 | 79.0 | ||||
2001-0 | 0.0 | 0.0 | ||||
2002-0 | 0.0 | 0.0 | ||||
2003-0 | 0.0 | 0.0 | ||||
2004-0 | 0.0 | 30.0 | ||||
2005-0 | 0.0 | 0.0 | ||||
2006-0 | 0.0 | 0.0 | ||||
2007-0 | 0.0 | 0.0 | ||||
2008-0 | 0.0 | 0.0 | ||||
2009-0 | 0.0 | 0.0 | ||||
2010-0 | 0.0 | 0.0 | ||||
2011-0 | 0.0 | 0.0 | ||||
2012-0 | 0.0 | 0.0 |
For data sources see[1]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION COMMENT |
---|---|---|---|---|---|---|
102678403 | 2012-07-23 | FOLLOW UP TO NOV # 826122208 The inspection revealed well is incapable of producing, according to Bruce Kellie(Owner) the down hole pump is stuck and will need a larger service rig to pull pump. According to landowner company had a service rig on well and was unable to remove stuck pump and removed rig without placing well into production. No production has been reported on well since 2004. All equipment at well and tank battery. Owner needs to place well into production or other actions approved by the Chief of Oil & Gas. | Compliance Notice | |||
102678403 | 2012-07-23 | FOLLOW UP TO NOV # 826122208 The inspection revealed well is incapable of producing, according to Bruce Kellie(Owner) the down hole pump is stuck and will need a larger service rig to pull pump. According to landowner company had a service rig on well and was unable to remove stuck pump and removed rig without placing well into production. No production has been reported on well since 2004. All equipment at well and tank battery. Owner needs to place well into production or other actions approved by the Chief of Oil & Gas. | Compliance Notice | |||
102678403 | 2012-07-23 | FOLLOW UP TO NOV # 826122208 The inspection revealed well is incapable of producing, according to Bruce Kellie(Owner) the down hole pump is stuck and will need a larger service rig to pull pump. According to landowner company had a service rig on well and was unable to remove stuck pump and removed rig without placing well into production. No production has been reported on well since 2004. All equipment at well and tank battery. Owner needs to place well into production or other actions approved by the Chief of Oil & Gas. | Compliance Notice | |||
102678403 | 2012-07-23 | FOLLOW UP TO NOV # 826122208 The inspection revealed well is incapable of producing, according to Bruce Kellie(Owner) the down hole pump is stuck and will need a larger service rig to pull pump. According to landowner company had a service rig on well and was unable to remove stuck pump and removed rig without placing well into production. No production has been reported on well since 2004. All equipment at well and tank battery. Owner needs to place well into production or other actions approved by the Chief of Oil & Gas. | Compliance Notice | |||
102678403 | 2012-07-23 | FOLLOW UP TO NOV # 826122208 The inspection revealed well is incapable of producing, according to Bruce Kellie(Owner) the down hole pump is stuck and will need a larger service rig to pull pump. According to landowner company had a service rig on well and was unable to remove stuck pump and removed rig without placing well into production. No production has been reported on well since 2004. All equipment at well and tank battery. Owner needs to place well into production or other actions approved by the Chief of Oil & Gas. | Compliance Notice | |||
102678403 | 2012-07-23 | FOLLOW UP TO NOV # 826122208 The inspection revealed well is incapable of producing, according to Bruce Kellie(Owner) the down hole pump is stuck and will need a larger service rig to pull pump. According to landowner company had a service rig on well and was unable to remove stuck pump and removed rig without placing well into production. No production has been reported on well since 2004. All equipment at well and tank battery. Owner needs to place well into production or other actions approved by the Chief of Oil & Gas. | Compliance Notice | |||
102678403 | 2012-07-23 | FOLLOW UP TO NOV # 826122208 The inspection revealed well is incapable of producing, according to Bruce Kellie(Owner) the down hole pump is stuck and will need a larger service rig to pull pump. According to landowner company had a service rig on well and was unable to remove stuck pump and removed rig without placing well into production. No production has been reported on well since 2004. All equipment at well and tank battery. Owner needs to place well into production or other actions approved by the Chief of Oil & Gas. | Compliance Notice | |||
1076097397 | 2004-02-08 | No production for three years ( all equipment present ) pulleys are rusty. New GPS | ||||
1085166216 | 2004-05-23 | Idle well put back into production. RESOLVED. | ||||
1105735673 | 2012-07-12 | Follow-up on Compliance Notice, In-Compliance. | ||||
-1107336784 | 2012-08-30 | Huffman Bowers on site running 200' cement plug at 1940', this is being chased with 15 barrels fresh water gel, the gel is chased with 8 barrels of fresh water to allow the clay to work properly. All 4.5 pulled, 1940.' Clay washed in on top of the precast plug set at 900'. | ||||
1317648744 | 2011-09-27 | An inspection of the well revealed no production reported since 2004 and well appears to be idle. All equipment on well and at tank battery, brush growing up around pumping unit and production tanks. No ID at well or tank battery. Plug, produce or place well on temporary inactive status. Submit production records to Columbus Office. Place full and legible ID at well and tank battery. Failure to comply may result in a forfeiture of bond. | ||||
1346854152 | 2012-09-05 | MH well service fininshing washing clay, they have rigged down. I have asked the well be left open for two weeks to allow for settlement. | ||||
-1599198207 | 2013-08-27 | Final restoration meets 1509.072. | ||||
-1747664447 | 2004-02-08 | FOLLOW UP TO NOV # 1076097397 No production for three years ( all equipment present ) pulleys are rusty. New GPS | ||||
1840499555 | 2012-08-28 | I received a call from Bruce Kelly, he was servicing this well and could not retrieve all the tubing, Huffman and Bowers on site, they were able to get circulation. I allowed Huffman Bowers to set 250' cement plug on bottom, there are to also set a 200' cement plug from 1700' to 1900', the rest will be clay. | ||||
-28712746 | 2013-07-09 | I inspected this well for the final inspection but the dike had not been put back yet. I talked with Bruce Kelly about the issue and he said he plans on getting it reclaimed as soon as it dried up. | ||||
431082699 | 2012-08-29 | MH well service has removed the 2 3/8 upset tubing, began ripping 4.5 casing at 1890' casing parted at 1650'.I spoke with Pat Shreve concerning the plug job, it was decided to set a 200 cement plug at 1650, then finish clay plugging once the precast plug is set on the 7 seat. | ||||
450289656 | 2012-07-23 | FOLLOW UP TO NOV # 826122208 The inspection revealed well is incapable of producing, according to Bruce Kellie(Owner) the down hole pump is stuck and will need a larger service rig to pull pump. According to landowner company had a service rig on well and was unable to remove stuck pump and removed rig without placing well into production. No production has been reported on well since 2004. All equipment at well and tank battery. Owner needs to place well into production or other actions approved by the Chief of Oil & Gas. | ||||
50130675 | 2012-07-23 | FOLLOW UP TO NOV # 450289656 FOLLOW UP TO NOV # 826122208 The inspection revealed well is incapable of producing, according to Bruce Kellie(Owner) the down hole pump is stuck and will need a larger service rig to pull pump. According to landowner company had a service rig on well and was unable to remove stuck pump and removed rig without placing well into production. No production has been reported on well since 2004. All equipment at well and tank battery. Owner needs to place well into production or other actions approved by the Chief of Oil & Gas. | ||||
681247520 | 2012-08-31 | MH well service clay plugging today, they will start pulling the 8 casing. | ||||
826122208 | 2012-07-23 | The inspection revealed well is incapable of producing, according to Bruce Kellie(Owner) the down hole pump is stuck and will need a larger service rig to pull pump. According to landowner company had a service rig on well and was unable to remove stuck pump and removed rig without placing well into production. No production has been reported on well since 2004. All equipment at well and tank battery. Owner needs to place well into production or other actions approved by the Chief of Oil & Gas. |
For data sources see[2]