34-035-22020

Well Details

Well ID: 34-035-22020
Loading map...
County: Cuyahoga
Municipality:
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2008-02-19
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.51687778
Longitude: -81.45053965

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2008-0 41395.0 149.0
2009-0 99609.0 64.0
2010-0 61290.0 74.0
2011-0 47245.0 35.0
2012-0 41985.0 51.0
2013-0 34061.0 0.0
2014-0 30583.0 365.0 0.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
-103531261 2009-01-06 well in parking lot no grass to be established. Dike around battery is poured cement and fencing on top of wall.
1212094705 2008-02-27 pits closed
-1340827679 2015-02-20 I inspected this well as part of routine inspection activity. The well and battery are located within the Golden Gate Shopping center. The wellhead mechanical plunger lift and battery are in separate board-on-board enclosures which are locked. Load-outs are plugged and locked. Secondary containment is constructed with masonry block and is robust. Fittings and connections are secure and free from signs of leakage or problems. Signage is present and accurate. Access to the wellhead and battery are from the general-use paved parking areas. Production reports are current.
1358977077 2012-01-16 I observed the unit to consist of the following elements: a two-tank battery wth mechanical separator and metering run enclosed within a integral concrete secondary containment dike and 8-foot board-on-board fence, and a wellhead unit which is similarly enclosed in a board-on-board fence. The gate and load lines were locked. The interior spacing of tank battery elements is in accordance with 1509 rules. I did not observe nor detect evidence of any leakage and/or spills of petroleum gases or liquids. There is a mechanical plunger lift apparatus affixed to the production wellhead. The valves and seals appear to be in good condition and are free from leaks. The unit is propertly identified at both the tank battery and wellhead.
1623576197 2008-02-22 cementing 85/8 casing good returns to surface
-1669322018 2011-04-04 Man door on the fence to the well, hasp lock is off center. While locking, lock a section of the board on board came off. Advised company of the board. Advised company hasp needs repaired. Man door needs to work and lock properly.
1789718511 2008-03-18 Pits closed
-2083919776 2008-02-25 drilling at 1800 no gas.
2132843743 2011-02-15 No violation
-314441964 2008-02-21 cementing 11.75 casing good returns to surface.
529061894 2011-02-15 No violation
773875198 2008-03-19 site check no violation
818447166 2008-04-01 pits closed
863963749 2008-03-10 running bond log was post pond

For data sources see[2]