X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-22000

Well Details

Well ID: 34-035-22000
Loading map...
County: Cuyahoga
Municipality:
Operator Name: PIPES PURSIE E
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2007-12-06
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.51135883
Longitude: -81.42956537

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2009-0 20944.0 52.0
2010-0 60108.0 131.0
2011-0 39154.0 60.0
2012-0 32496.0 49.0
2013-0 22170.0 0.0
2014-0 15007.0 365.0 54.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
-118841570 2009-10-28 No violation
1199673984 2014-08-19 I inspected this producing unit as part of routine inspection activity. The well was completed in 12/16/2007. The unit is producing and production reports are current. The well is located in a upscale suburban area with large lots, and densely wooded areas around the well and battery. The producing unit is accessed via a dedicated, gravel-paved access road which extends 1,100 feet southeast from Cottesworth Lane. The access road is level, and well drained with no signs of erosional deficits. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger-lift system and aboveground storage tank (AST) battery in separate board-on-board enclosures. The valve fittings, connections, and other production appurtenances appear to be well maintained and are free from signs of leakage or other problems. The battery is comprised of 1 steel 100-barrel production tank, 1 50-barrel steel brine tank, and separator unit. Spacing from well to battery, and spacing of elements within the battery meet regulations. The load-outs are bull-plugged. There is secondary containment at the battery and the interior areas are dry. I did not observe any signs or evidence of leakage, spills, or problems. Unit identification placards are present at both the battery and wellhead, but are in poor condition and no readable. I notified the well owner about the need for new ID placards. I observed no other issues or problems requiring attention at the time of my inspection.
1219776073 2008-02-05 water flowing into sewer system causing a problem with flooding the system.
137073840 2008-02-05 no violation working
-1497396265 2009-08-17 no violations
1834316353 2008-05-07 violation corrected
248810516 2007-12-06 rigging up rig.
-894143276 2007-12-12

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 