Well ID: 34-155-22406
Loading map...
County: Trumbull
Municipality:
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1984-02-09
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.25896561
Longitude: -80.52193975

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1984-0 25884.0 55.0
1985-0 34172.0 0.0
1986-0 19573.0 34.0
1987-0 15280.0 0.0
1988-0 14451.0 0.0
1989-0 15516.0 72.0
1990-0 11468.0 0.0
1991-0 6320.0 0.0
1992-0 6661.0 0.0
1993-0 4457.0 0.0
1994-0 2359.0 0.0
1997-0 5551.0 0.0
2000-0 5201.0 0.0
2001-0 6146.0 0.0
2002-0 5680.0 35.0
2003-0 4179.0 0.0
2004-0 3326.0 0.0
2005-0 4659.0 0.0
2006-0 2790.0 0.0
2007-0 3098.0 0.0
2008-0 1982.0 0.0
2009-0 2374.0 0.0
2010-0 2601.0 0.0
2011-0 1640.0 0.0
2012-0 2669.0 0.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1308588251 2011-06-17 An inspection found the well site covered in ruts. Ruts in lease road were starting to erode. The flow line was buried, but the trench was left open. Coupling on the one inch line was leaking natural gas.

1. Repair the leak.

2. Backfill the ditch between the well and tank battery.

3. Repair the ruts on the lease road and well site.

4. Seed and mulch the area disturbed.

1354631475 2012-12-04 My NOV follow-up inspection, written by ODNR Inspector Steve Ochs on 6/17/2011, found the ruts filled.
708525451 2011-06-17 FOLLOW UP TO NOV # 1308588251 An inspection found the well site covered in ruts. Ruts in lease road were starting to erode. The flow line was buried, but the trench was left open. Coupling on the one inch line was leaking natural gas.

1. Repair the leak.

2. Backfill the ditch between the well and tank battery.

3. Repair the ruts on the lease road and well site.

4. Seed and mulch the area disturbed.

-895800933 2011-11-02 The ruts in the well site and lease road need repaired. The disturbed area, where the flow line was buried, needs graded.
PL3850 Preliminary Restoration done information from Data Point