Well Details

Well ID: 34-153-20065
Loading map...
County: Summit
Municipality:
Operator Name: NORTHWOOD ENERGY CORP
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1961-02-11
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.17097385
Longitude: -81.68458209

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1984-0 3268.0 424.0
1985-0 4079.0 409.0
1986-0 2918.0 457.0
1987-0 2819.0 440.0
1988-0 2779.0 383.0
1989-0 2727.0 398.0
1990-0 1225.0 282.0
1991-0 1256.0 270.0
1992-0 477.0 186.0
1993-0 876.0 291.0
1994-0 658.0 149.0
1995-0 604.0 185.0
1996-0 626.0 168.0
1997-0 682.0 78.0
1998-0 646.0 69.0
1999-0 814.0 49.0
2000-0 518.0 144.0
2001-0 840.0 68.0
2002-0 443.0 147.0
2003-0 762.0 67.0
2004-0 682.0 60.0
2005-0 330.0 0.0
2006-0 289.0 42.0
2007-0 127.0 56.0
2008-0 545.0 57.0
2009-0 82.0 47.0
2010-0 217.0 51.0
2011-0 202.0 55.0
2012-0 168.0 59.0
2013-0 113.0 131.0
2014-0 21.0 365.0 37.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
-1150137478 2002-10-07 FOLLOW UP TO NOV # 362: The tank battery, consisting of two 100 bbl tanks and one vertical separator is approximately 15 feet west of the traveled portion of Medina Line Road. The tank battery has no secondary containment dike. One must be installed in order to prevent any spil Phone Call
-1150137478 2002-10-07 FOLLOW UP TO NOV # 362: The tank battery, consisting of two 100 bbl tanks and one vertical separator is approximately 15 feet west of the traveled portion of Medina Line Road. The tank battery has no secondary containment dike. One must be installed in order to prevent any spil Phone Call
1294957748 2002-12-17 An earthen dike has been constructed around the stock tanks as required. The violation has been corrected.
2097717217 2009-11-03 I received a call from Russ Mazzola (330-670-5235) at 1315 Medina Line Road requesting an inspection of this well, which is located on his neighbors property. The well was drilled in 1961 and therefore pre-dates most regulatory requirements. The chain link fence around the well does not have a working gate and the area around the well is overgrown. I will contact Northwood about the maintenance issues.
36270622 2002-10-07 The tank battery, consisting of two 100 bbl tanks and one vertical separator is approximately 15 feet west of the traveled portion of Medina Line Road. The tank battery has no secondary containment dike. One must be installed in order to prevent any spill from directly impacting the road surface.

For data sources see[2]