34-053-20241

Well Details

Well ID: 34-053-20241
Loading map...
County: Gallia
Municipality:
Operator Name: OHIO VALLEY ELECTRIC CORP
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1977-07-16
Unconventional: No
Configuration: Vertical
Well Status: Final Restoration
Violations: 0
Latitude: 38.92021072
Longitude: -82.15203241

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1984-0 914.0 75.0
1985-0 1289.0 68.0
1986-0 1576.0 111.0
1987-0 1548.0 67.0
1988-0 1470.0 65.0
1989-0 1411.0 63.0
1990-0 1327.0 62.0
1991-0 1234.0 60.0
1992-0 1110.0 58.0
2000-0 1007.0 48.0
2001-0 336.0 0.0
2002-0 605.0 38.0
2003-0 306.0 0.0
2004-0 90.0 0.0
2005-0 126.0 0.0
2006-0 164.0 30.0
2007-0 9.0 8.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
-1000227438 2008-04-03 Ohio Valley Electric Corp. is constructing a landfill for FGD generated from the Kyger Creek Power Plant. The well site is located within the landfill project area and excavation to the location is underway. OVEC has submitted a landowner waiver for the restoration due to their construction of the landfill.
1269570151 2007-11-21 Set bottom hole plug. Used the bullhead method to place the plug in the casing.
1269i713 2002-01-24 Follow-up on NOV , Non - Complinace, no action to comply with NOV.
1269i802 2002-02-20 Follow-up on NOV, In-Compliance.
-1288682891 2007-11-20 One of the next wells on plug list. Took GPS on well and checked status. All tubing and rods pulled and pump jack removed.
171945053 2005-10-06 Need to correct RBMS coordinates; well is shown in same location as 20246.
-826897221 2004-02-04 Need to pick up trash and move old jack out
865414693 2003-04-18 No violations at the time of inspection.
-882986582 2007-11-26 Timco TD top of 1st plug at 1386'. Timco tried to shot at 1341' charge did not detonate. Pulled out of hole and corrected the problem. Ran charge back down the hole and shot at the wrong elevation of 1241' instead of 1341'. The casing did not come free due to the fact that the casing is 30' joints and the shot was exactly 100' above the target collar at 1341'. Timco shot a second time at 1253' and the casing came free. Set the Injun plug, Cow run plug, and a 200' to surface plug. 1253' of casing was removed from the well. Cement stayed at the surface.
-948017497 2007-03-12 Well has been damaged by logging operation for AEP's new land fill. A 1 nipple was broken off in a tee. This caused the line to leak badly. The pumper was able to shut a valve and stop the gas flow. The well is currently not in production due to the logging. AEP was notified of the damage to the well.

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 