X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-053-20394

Well Details

Well ID: 34-053-20394
Loading map...
County: Gallia
Municipality:
Operator Name: MOLZ MARTIN-OLIO RES LLC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1990-09-07
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 38.84240945
Longitude: -82.16435224

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1993-0 155.0 152.0
1997-0 25.0 50.0
2000-0 300.0 80.0
2001-0 400.0 90.0
2002-0 500.0 85.0
2003-0 375.0 60.0
2004-0 730.0 85.0
2005-0 250.0 60.0
2006-0 570.0 108.0
2007-0 425.0 100.0
2008-0 0.0 0.0
2009-0 270.0 34.0
2010-0 504.0 191.0
2011-0 449.0 176.0
2012-0 389.0 132.0
2013-0 153.0 125.0
2014-0 58.0 365.0 140.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1044289334 2003-01-31 Preliminary restoration meets state requirements. Compliance Notice
1044289334 2003-01-31 Preliminary restoration meets state requirements. Compliance Notice
119993860 2015-01-14 FOLLOW UP TO NOV # -622626037. Closed by Morgan Button 2-26-14.
-1609590870 2013-04-03 FOLLOW UP TO NOV # -622626037 This well is in an urban township according to 2010 US Census. Therefore, the operator must comply with the urban rules listed below in the violation window A more comprehensive description is included with this compliance notice. This well and its tank battery identification signs do not meet the following requirements: 1501:9-9-05E1/1509:3D. Under urban rules signs must meet a certain standard different from normal production wells and tank batteries. Signs must be attached to required fencing. Fences are missing around the wellhead/ pumping unit apparatus. According to 1501:9-9-05E2/1509:03D, fencing specifications must be followed surrounding the tank battery and wellheads. Tanks must also be checked to ensure they are in compliance with 1501:9-9-05E4/1509:03D. Locks must be place where specified according to the regulation 1501:9-9-05E3/1509:03D. Access road to this well and Woods-Cotton #1 tank battery is off access road to Molz Martin-Olio Res LLC's Robert Henry #1(API # 3405320395), Russell Woods #2 (API # 3405320945), Russell Woods #3 (API # 3405320952), and Wood-Cotton # 1 (API # 3405320988) GPS at the entrance of this road is 38..84221/ -82.16500. Tank battery consists of two 100-barrel steel tanks, small, approximately one barrel oil water separator on top of one of the 100 barrel tanks, and a tall liquid/gas separator in a dike containment area. The 100-barrel tanks are manifold together. The well has a pumping unit lifting product from the 1-3/4 inch tubing which rises out and above 4-inch intermediate casing which is rising from 6-3/8 inch surface casing. Besides production from the production tubing there is also production from the annular space of the intermediate casing and the production tubing.
1803471380 2007-01-04 Well looks good. Noticed a strong gas smell near tanks, I am going to contact owner about this.
-622626037 2013-04-03 This well is in an urban township according to 2010 US Census. Therefore, the operator must comply with the urban rules listed below in the violation window A more comprehensive description is included with this compliance notice. This well and its tank battery identification signs do not meet the following requirements: 1501:9-9-05E1/1509:3D. Under urban rules signs must meet a certain standard different from normal production wells and tank batteries. Signs must be attached to required fencing. Fences are missing around the wellhead/ pumping unit apparatus. According to 1501:9-9-05E2/1509:03D, fencing specifications must be followed surrounding the tank battery and wellheads. Tanks must also be checked to ensure they are in compliance with 1501:9-9-05E4/1509:03D. Locks must be place where specified according to the regulation 1501:9-9-05E3/1509:03D. Access road to this well and Woods-Cotton #1 tank battery is off access road to Molz Martin-Olio Res LLC's Robert Henry #1(API # 3405320395), Russell Woods #2 (API # 3405320945), Russell Woods #3 (API # 3405320952), and Wood-Cotton # 1 (API # 3405320988) GPS at the entrance of this road is 38..84221/ -82.16500. Tank battery consists of two 100-barrel steel tanks, small, approximately one barrel oil water separator on top of one of the 100 barrel tanks, and a tall liquid/gas separator in a dike containment area. The 100-barrel tanks are manifold together. The well has a pumping unit lifting product from the 1-3/4 inch tubing which rises out and above 4-inch intermediate casing which is rising from 6-3/8 inch surface casing. Besides production from the production tubing there is also production from the annular space of the intermediate casing and the production tubing.
767032815 2004-02-10 No problems observed. Need to remove abandoned tank.
799026090 2014-02-26 This well was originally cited for Urban Rules violations. There are no longer enforced for this well since this well was drill prior to the implementation of these rules. Well has a complete and accurate identification sign and the operator has already reported 2013 oil and gas production. There are currently no issues on this well.

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 