34-055-21199

Well Details

Well ID: 34-055-21199
Loading map...
County: Geauga
Municipality:
Operator Name: [[EDC

]]

Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1986-06-18
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.37706535
Longitude: -81.11432991

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1986-0 693.0 93.0
1987-0 3497.0 904.0
1988-0 2485.0 881.0
1989-0 1438.0 741.0
1990-0 4704.0 1167.0
1991-0 1457.0 486.0
1992-0 1584.0 1039.0
1993-0 2131.0 1029.0
1994-0 1748.0 902.0
1995-0 1179.0 810.0
1996-0 907.0 849.0
1997-0 655.0 575.0
1998-0 1270.0 810.0
1999-0 665.0 552.0
2000-0 647.0 535.0
2001-0 727.0 641.0
2002-0 279.0 216.0
2003-0 308.0 569.0
2004-0 878.0 589.0
2005-0 759.0 561.0
2006-0 1142.0 329.0
2007-0 1108.0 533.0
2008-0 1448.0 493.0
2009-0 709.0 351.0
2010-0 1144.0 478.0
2011-0 1055.0 493.0
2012-0 1351.0 360.0
2013-0 1061.0 397.0
2014-0 1154.0 365.0 390.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1461066670 2013-04-29 My inspection found the well to be equipped with a pump jack. The well and tank battery are in good repair. The tank battery consists of a 210 BBL production tank, a 50 BBL brine tank, and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition.
762057199 2007-09-26 Well is a pump jack well. Tank battery has a new 210 BBL tank and 35 BBL plastic tank it. Mechanical separator in the tank battery. Dike is in good repair. There is a 1/2 inch fitting leak at the separator. Line is disconnected from the fitting, valve is not closed completely. Spoke with Pat at North Coast Energy's office, he will have issue taken care of. Phone # 330-527-5630 ID sign need on the tank battery. Repair line leak.
790427150 2003-09-30 210BBl-plastic brine-seperator dike
-87148238 2007-10-12 Well has been signed and gas leak at the separator has been repaired.

For data sources see[2]