Well ID: 34-019-22628 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.57364391,"lon":-80.97161238,"icon":""}]} |
County: | |
Municipality: | |
Operator Name: | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 2014-11-04 | |
Unconventional: | |
Configuration: | |
Well Status: Well Drilled | |
Violations: 0 | |
Latitude: 40.57364391 | |
Longitude: -80.97161238 |
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION COMMENT |
---|---|---|---|---|---|---|
-1135359901 | 2015-02-18 | Per the Divisions request Chesapeake Exploration LLC. Is monitoring the pressure between the surface casing annulus and the intermediate casing. At the start of the monitoring there was a 0-10K pressure gauge installed on the casing I requested that they change that to a 0-5K pressure gauge. The pressure gauge was changed on 1/22/2015. At present there was no noted pressure on the gauge. They are monitoring the pressure daily. They are to notify myself or Northeast Regional Supervisor Tom Hill of any changes. | ||||
1417452076 | 2014-11-19 | On site with District Supervisor - Rick Anderson and Regional Supervisor - Tom Hill to conduct a status check on drilling operations related to the Nomac Drill Rig #77. Met with the company man on site to review the status of the drilling. At that time, the drilling had been stopped to conduct a drill depth survey which was at 6100 feet. The blow-out preventer was in place and in good condition. The permit was posted and test charts were in compliance and on site in the company man trailer. The spill prevention controls were in good condition and installed accordingly. Overall the site was in compliance. No violations were found. | ||||
1418654621 | 2014-11-05 | Tophole Drilling drilled a 26 hole to a depth of 120' and ran 120' of 20 94 #/ft. welded conductor casing. Express Energy Services pumped 9 barrels of fresh water ahead followed by 230 sacks of class A cement with 2% CaCl and .05 lb/gal of floseal. Displaced with 39 barrels of fresh water. 10 barrels of cement returned to surface. | ||||
1421338814 | 2014-12-23 | On December 22, 2014, DOGRM Inspector Robert Roush was on site to witness the installation and cementing of the surface casing at the CTF 32-13-4 #2H. While reviewing drilling information from prior wells on the CTF pad, Inspector Roush discovered that the surface casing for the first well drilled on the pad, the CTF 32-13-4 #205H had been set at 519 | ||||
1423077611 | 2015-02-02 | Per the Divisions request Chesapeake Exploration LLC. Is monitoring the pressure between the surface casing annulus and the intermediate casing. At the start of the monitoring there was a 0-10K pressure gauge installed on the casing I requested that they change that to a 0-5K pressure gauge. The pressure gauge was changed on 1/22/2015. At present there was no noted pressure on the gauge. They are monitoring the pressure daily. They are to notify myself or Northeast Regional Supervisor Tom Hill of any changes. | ||||
-1540842559 | 2015-01-22 | I was on location to discuss the monitoring of the pressures between the surface casing annulus and intermediate casing. Per the Divisions request Chesapeake Exploration LLC. Is monitoring the pressure between the surface casing and the intermediate casing. At the start of the monitoring there was a 0-10K pressure gauge installed on the casing I requested that they change that to a 0-5K pressure gauge. At present there was no noted pressure on the gauge. They are monitoring the pressure daily. Thy are to notify myself or Northeast Regional Supervisor Tom Hill of any changes. | ||||
1965306408 | 2014-11-05 | I was on site to witness the cementing of the conductors for the CTF 32-13-4 #2H, 5H, and 10H when Chesapeake company man Gene Belsom asked me about fluid drilling requirements as a result of the alleged location of water well #995175 within 500 feet of the wells.. State records showed the location of the water well to be approximately 220 feet from the nearest well, the #6H, and located within the already constructed pad in southwest corner 45 |