X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-22621

Well Details

Well ID: 34-155-22621
Loading map...
County: Trumbull
Municipality:
Operator Name: OHIO VALLEY ENERGY SYSTEM CORP
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1984-10-15
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.21382225
Longitude: -80.87994364

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1985-0 6063.0 332.0
1986-0 13164.0 282.0
1987-0 8629.0 198.0
1988-0 13444.0 528.0
1989-0 9407.0 352.0
1990-0 21603.0 530.0
1991-0 15434.0 462.0
1992-0 12826.0 300.0
1993-0 10472.0 180.0
1994-0 8964.0 147.0
1995-0 7015.0 144.0
1996-0 1542.0 0.0
1997-0 7843.0 109.0
1998-0 8210.0 130.0
1999-0 6838.0 88.0
2000-0 6660.0 145.0
2001-0 5251.0 96.0
2002-0 1312.0 65.0
2003-0 4585.0 36.0
2004-0 5281.0 93.0
2005-0 4757.0 121.0
2006-0 4795.0 73.0
2007-0 4290.0 28.0
2008-0 4778.0 60.0
2013-0 2731.0 38.0
2014-0 4205.0 365.0 101.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1375273800 2013-07-17 My inspection found the well in production. The well was equipped with a plunger lift unit. I noticed a flow line leak approximately 15' northeast of the wellhead in a 10' x 3' water puddle. The tank battery contained a 100 barrel production tank, a 50 barrel brine tank, and a separator. The dike was weathered and not capable of meeting containment requirements. There was a plug on the load line. Identification signs were posted on the production tank and well. There was a 7 day production chart at the separator. The lease road was in good condition. I called Don Nething at 330-283-5758. I instructed him to send the well tender to isolate the leak and make repair to the flow line. Also, I told him to build a new dike capable of meeting containment requirements.
-1751297846 2013-07-30 My inspection found the flow line leak repaired per my request.
PL3690 Preliminary Restoration done information from Data Point

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 