Well ID: 34-147-20404 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.00966482,"lon":-83.3252072,"icon":""}]} |
County: Seneca | |
Municipality: | |
Operator Name: NORSTAR OPERATING LLC | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 2007-01-15 | |
Unconventional: No | |
Configuration: Vertical | |
Well Status: Producing | |
Violations: 0 | |
Latitude: 41.00966482 | |
Longitude: -83.3252072 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
2007-0 | 0.0 | 0.0 | ||||
2014-0 | 0.0 | 0.0 | 0.0 | 0.0 |
For data sources see[1]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION COMMENT |
---|---|---|---|---|---|---|
1209003411 | 2007-02-06 | Drilling well. Drill in to formation at 1454 feet. Gas pressuer 400psi, H2S greater than 10,000 ppm. , tested with Dragger tubes. | ||||
1410284014 | 2014-09-04 | This inspection was done as a follow-up to Compliance Notice #545311609 written on 12-6-2012. At the time of the inspection the well has a stone access lane with a gate by the road. The identification for the well is posted on the gate. The tank battery has 2 steel tanks and 2 plastic tanks inside an aluminum dike lined with stone. There is also a heater/separator in a separate aluminum dike. The well is set up for production but is shut in at the wellhead and is not being produced. The operator, Norstar Operating LLC, would like to sell the well but has been unable to do so. No statements of annual production have been filed and the well needs to be plugged. | ||||
167023437 | 2014-11-13 | Location Information for the Summit K. Unit #1 (#404). WELL HEAD: Lat. 41.00965 Long. -83.32494 / CENTER-OF-STORAGE: Lat. 41.00970 Long. -83.32465 / ENTRANCE: Lat. 41.00965 Long. -83.32448. | ||||
-1679747535 | 2014-11-13 | Inspected the Summit K. Unit #1 (#404) as part of a standard compliance notice follow up. The well is shut-in and not in production. Status: non-compliant. Updated GPS coordinates and photo documented. | ||||
-2104475945 | 2009-12-16 | well in production. Site ok. | ||||
-232854456 | 2015-05-11 | Chief's Order #2015-147 Plugging Required issued 4/10/2015. | ||||
237774366 | 2007-12-11 | Inspect well. Well shut in. A trench has recently been dug and is open from well head to tank battery. | ||||
-290031280 | 2007-04-18 | Inspect well. Well has been completed. Construction of tank storage pad in progress. | ||||
291875980 | 2007-01-24 | Drilling new well. Surface casing has been set. | ||||
-545311609 | 2012-11-28 | Inspect well. well with pump jack. Well is shut in. Two 210 bbl tanks that are empty, one poly brine tank that is half full. Plug well. prodcution reports have not been submitted since 2007. | ||||
-847922688 | 2012-11-28 | FOLLOW UP TO NOV # -545311609 Inspect well. well with pump jack. Well is shut in. Two 210 bbl tanks that are empty, one poly brine tank that is half full. Plug well. prodcution reports have not been submitted since 2007. | ||||
-85540104 | 2007-07-02 | Inspect location. Site graded. Tanks and dike system constructed. Service rig on locaton. Well shut-in. |