34-169-60992

Well Details

Well ID: 34-169-60992
Loading map...
County: Wayne
Municipality:
Operator Name: MORTON SALT INC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1957-01-30
Unconventional: No
Configuration: Vertical
Well Status: Final Restoration
Violations: 0
Latitude: 40.96468248
Longitude: -81.7743387

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
10308971 2007-08-03 Arrive to check plug and found that log truck is running late .Next after log Halliburton is running late.Did get well cemented to surface with two 650 plugs
-1209614225 2007-07-31 Arrive today and use Appalachian to shoot casing again at 1570 ft. still could not pull casing so run in hole with packer to 470 ft. and try and circulate well .Start at 500 psi and after 2.75 hrs of pumping up against it was able to get enough movement that well could circulate and then casing could be pulled .Cancell plug for today while crew lays down 8 inch and runs back in with tubing .
-1360790013 2007-09-17 Check area for leaks and found that well is still leaking and pits have not been pumped off.The area around the well is no longer flooded.
-1362131614 2003-12-09 CHECKED ID - OK
-1451704494 2007-08-02 Arrive today for plug and found that Halliburton has cancelled for now and may be ready tonight . Return later that night and Arvilla ran tubing in to 1650 ft. and Halliburton set 300 ft. plug with gas block cement to 1350 ft.
1532169493 2007-09-10 This well has been plugged and the pits needs pumped and the area needs graded. There is gas leaking from well and it should be vaulted and vented.Also note that the entire area is under water and the water is saturated brine.
1583339139 2007-09-17 Area is not flooded today but well is still leaking .Pits remain and need pumped off and closed.
1594031182 2007-07-26 Superior Well service set wire line plug at 2275 ft. and then ran bond log.
-1615984963 2007-07-27 W/O equipment to test well .Flange is broken and there is no way to connect up to well for test .Welder is on the way ,Then is almost there and breaks down and thinks he can make repairs and then test is cancelled .
-2074508707 2013-03-21 Appears to be in compliance.
-408998726 2007-10-10 Pits are closed and there is a small amount of gas leaking on the outside of well casing.
487672200 2008-09-09 There remains a small amount of gas bubbling out of well .It should be vaulted and vented.There are 3 wells which are leaking on the Morton facility that if by spring continue to leak will all be issued notice to vent and vault.
-652925749 2007-09-10 Check well after it has been plugged and found that there are still gas leaks around well and that the pits are full and have not been closed.
702872890 2007-07-28 Arrive today and test well up to 400 psi and then casing blew out at 3 ft. .Next run in with tubing to 2270 ft. and set plug from 2270 ft. to 1670 ft. and reverse circulate to clear cement .
-718041724 2007-08-01 Pulling casing still and had problem getting casing apart. Looks like job will be cancelled for today.
823005275 2007-11-08 Check final restoration and found that area needs graded and material removed after plugging.
-985489613 2007-07-30 Tag plug at 1700 ft and then cut 8 inch casing at 1630 ft. and could not pull casing .Shot again at 1570 and again at 1570 ft . And could not pull casing .Advise use packer and circulate well to clear backside obstructions.