X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-117-22260

Well Details

Well ID: 34-117-22260
Loading map...
County: Morrow
Municipality:
Operator Name: M & R INVESTMENTS OHIO LLC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1986-12-10
Unconventional: No
Configuration: Vertical
Well Status: Active Injection
Violations: 0
Latitude: 40.52896994
Longitude: -82.8618974

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1996-0 0.0 0.0
1997-0 0.0 0.0
1998-0 0.0 0.0
1999-0 0.0 0.0
2000-0 0.0 0.0
2001-0 0.0 0.0
2002-0 0.0 0.0
2003-0 0.0 0.0
2004-0 0.0 0.0
2005-0 0.0 0.0
2006-0 0.0 0.0
2008-0 0.0 0.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
-1030111812 2004-12-28 Chk well and storage, Ok. The site is snow covered. Compliance Notice
104566912 2013-06-12 Operator has ordered a new packer and tubing, which should take approximately two weeks. Service work to begin soon after.
1053369599 2003-05-19 Chk well and storage, Ok.
1064414650 2003-09-24 Chk well and storage, pump is running at this time. Ok
1073927150 2004-01-12 Vault is full.

ID at well head and needs remarked at tank. 01-14-04 Called Paul Mullins 419/946-6535, 1:01/ 03 PM. left message on above comments. J.F.

1078864858 2004-03-09 Chk well and storage,Ok.
1103191329 2011-01-03 Check well and storage. Pump is running at this time
1126885255 2005-09-16 Ch well and storage, Ok.
-1136702765 2009-12-17 Check well and storage, injection pump is running at this time.
1159981894 2006-10-04 Chk well and storage, ok.
1190916777 2007-09-27 Chk well and storage, Ok.
1200340119 2008-01-14 Chk well and storage, Ok.
1210i856837 2002-03-20 Well and facility appear ok.
1229i321 Chk storage OK. Need to remove fluid from vault. Did not chk the well at this time.
1255026632 2009-10-08 Chk well and storage, Ok. No fluid in dike at this tme. A new injection pump, lines and filter have been installed inside of the dike.
1273773750 2010-05-13 Chk well and storage ok.
1284695848 2013-07-08 Operator reported that there was 130 feet of fluid in the 4.5 inch casing and the frac sand was filled from total depth of 3220 feet to 2960 feet. A Bond log performed by the operator indicated perforations from 3108 to 3113 feet. The top of the cement for the 4.5 inch casing was at 2430 feet. The service company used an Halliburton R-4 packer to attempt to locate the hole in the 4.5 inch casing. Repeated testing at subsequently shallower depths the hole in the casing was determined to be between 62 and 90 feet below grade. See 12/12/2011 report for field activities previously conducted.
1287i103 2001-06-25 check of tanks and well head annulas 0 tubbing 300
1296012551 2007-01-31 Inspect well.
1297153999 2004-09-30 Chk well and storage, Ok.
1305031905 2011-05-10 Check well and storage, injection pump in running at this time. No problems to report at this time.
1322674694 2011-11-27 Operator pressured up well as requested. Pressure test failed. Well was shut in. Operator anticipates service rig on 12/1/2011 to pull and replace tubing.
1323893292 2011-12-12 Operator has determined that there is a hole in the 4.5 inch casing, below 200 feet. A bridge plug was set at 260 feet by Appalachian services by wire line. Omega Cementing Co. bull head pumped 70 sacks of cement until circulation on back side of 4.5 inch
-1330160146 2014-07-30 Inspect well for integrity and pressure. The storage tank has holes and is shut in. The annulus had a slight vacuum that diminished to zero when the valve was opened.
1359054028 2013-01-24 M & R has updated the well identification and emergency contact information as requested.
1365689728 2013-04-11 Inspected the Shaffer & Holzbacher #1 (#54) (SWIW #54) as part of a standard injection well status check. Status: well is out of service.
1372781478 2013-07-02 Glen Davis service rig is rigged-up on the injection well to perform service work.
1374858891 2013-07-26 On site with Inspector Benko to witness Mechanical Integrity Test. Test passed. Status: well may be placed back into injection.
1375293288 2013-07-31 The work over pits have been emptied and closed and the site has been graded. The well identification and emergency contact information is posted at the well and storage, no trespassing signs are posted at the storage. Status: ok.
1375456811 2013-08-02 Connection of the flow line (injection line) to the disposal well at the well head has not occurred as of 8/2/2013. Status: Disposal has not commenced, ok.
1375459546 2013-07-10 Inspect well, Universal cemented to the surface the 2-7/8 inch liner installed inside of 4.5 inch production casing.
1377106819 2013-08-21 Inspected the Shaffer #1 (SWIW #54) as part of a standard injection well status check. Check well, storage and identification. The injection well has been hook-up and is in service. Status: ok.
1380558666 2013-09-30 Inspected the Shaffer & Holzbacher #1 (SWIW #54) as part of a standard injection well status check. Check well, storage, vault and identification. No change in status from previous inspection. Status: ok.
1385409246 2013-11-25 Inspected the Shaffer #1 (SWIW #54) as part of a standard injection well status check. Check well, pressures, storage, vault and identification. No change in status from previous inspection. The well is not in service. Status: ok.
1387218344 2013-12-16 Inspected the Shaffer & Holzbacher #1 (SWIW #54) as part of a standard injection well status check. Check well, pressures, storage, vault and identification. No change in status from previous inspection. Status: ok.
1389979961 2014-01-17 Inspected the Shaffer & Holzbacher #1 (SWIW #54) as part of a standard injection well status check. Check well, pressures, storage, vault and identification. No change in status from previous inspection.
1393009147 2014-02-21 Inspected the Shaffer & Holzbacher #1 (#2260) as part of a standard injection well status check. Inspect well, pressures, storage and identification. Status: no change in status from previous inspection.
1394823377 2014-03-14 Inspected the Shaffer & Holzbacher #1 (SWIW #54) as part of a standard injection well status check. Inspect well, pressures, storage, vault and identification. Status: no change in status from previous inspection. The well has not been placed into injection as the storage tank needs replaced. There are multiple visible 1/8 to 1/4 inch holes on the single horizontal tank .
1428207879 2011-02-09 Check well and storage. The site is snow covered. Appprox temp 12 degrees F

The pump is not running at this time.

145950130 2003-03-21 Chk well and storage,Ok.
-1464543029 2013-07-24 Operator reported that they continue to drill on cement at a depth of 2993 feet that is below the depth of the 2-7/8 inch liner casing at 2958 feet.
1468093571 2007-08-07 Chk well and storage, injection pump is running at this time.
1495956903 2007-03-29 inspect well.
1576011001 2013-02-21 Injection well status check: Identification posted, well is currently not in operation.
-1593198250 2004-11-03 Chk well and storage, Ok.
1600864289 2007-11-01 Chk well and storage, Ok . Injection pump is running at this time.
1615269893 2008-06-16 Chk well and storage,Ok.
163311483 2003-02-21 Chk well and storage,OK.
1634716200 2014-08-22 Inspected the Shaffer & Holzbacher #1 (SWIW #54) as part of a standard injection well status check. Inspect well, pressures, storage and identification. Status: ok.
-1638892112 2013-07-25 Contacted by operator to report that cement has been drilled out and the frac sand has been washed out of the well. The well was circulated for more than 4 hours.
-1644265202 2008-12-11 Check well and storage, OK.
-165909054 2009-02-23 Chk well and storage, ok.
-1706714370 2011-12-05 On site for running of tubing and packer in injection well. Upon pressuring up of annulus a leak was discovered in 4.5 casing. Operator will work over next couple days to remedy.
-1746048774 2004-08-04 Chk well and storage. Should do a pressure test on the injection line. The agricultural crop that is planted over the line is turning brown and dieing. May have a leak in it.
-1804306241 2011-06-16 An inspection was conducted with Mr. Will Ziegler. Please refer to Ziegler
-1832882859 2014-05-27 Inspected the Shaffer & Holzbacher #1 (SWIW #54) as part of a standard injection well status check. Inspect well, pressures, storage and identification. Status: No change in status from previous inspection
-1899659542 2013-07-03 Operator reported that the 15 sacs of frac sand was going to be delivered and installed into the well to cover the perforations. Anticipated to run pipe on Monday.
1911351829 2014-12-16 Inspect location. Well is not in use. The storage tank requires repair or replacement.
1917562564 2011-06-16 I inspected the well location with Brent Bear. There is proper display of identification posted at the well location. The wells injection pressure was 40psi. There was 60 psi showing on the annulus. There are no violations noted this date.
-192818671 2013-06-28 Gene Varner contacted inspector to report that Davis Well Service will begin the remedial actions as outlined in the May 23, 2012 request for well construction modification. The bride plug previously set was going to be drilled out and frac sand installed into the 4.5 inch casing to protect the perforations for the injection zone.
1931466374 2010-08-02 Check well and storage, new dike built around tank. Solid concrete with a sealer painted on the inside.
1971969504 2005-07-28 Chk well and storage, Ok.
1994940191 2015-03-13 Inspected the Shaffer & Holzbacher #1 (SWIW #54) as part of a standard injection well status check. Inspect well, pressures, storage and identification. Status: no change-in-status from previous inspection.
-2033777912 2009-06-24 Injection pump is running at this time. The annulus and injection pressures are at 150 psi. Need to return to the site when pump is shut down and recheck the annulus pressure.
2053119111 2009-03-30 All new fittings installed on injection tubing.
2096327499 2013-05-22 Check injection well. Operator has posted new identification and emergency contact information as well as no trespassing signs. Status: well is out-of-service, non-compliant.
2123340067 2013-03-13 Inspect storage tank area. The well is shut in. Measure tank storage dike area. Precast concrete dike area. One 372 bbl lay down horizontal tank.
-2126701946 2013-07-15 Operator reported that they tagged the displaced cement for the 2-7/8 inch liner at 2625 feet. Drilling will commence to clean out the hole.
-243064322 2009-03-19 Chk well and storage, need to replace valve on injection tubing. Could not chk injection pressure.
-278025843 2012-10-24 Inspected the Shaffer & Holzbacher #1 (#2260) (SWIW #54) as part of a standard injection well status check. As previous inspections revealed, well remains out-of-service and incapable of injection, the tubing is on ground next to well, pits are open and the liners have fallen in. Well identification is faded at the storage. The unloading pad need maintenance. Status: Inactive.
29818701 2014-10-10 Inspect well for integrity and pressure. The well is shut-in.
32173702 Chk storage OK. Need to remove fluid from vault. Did not chk the well at this time.
-331638066 2004-08-17 New injection line has been installed.
-348662970 2010-08-11 Inspected Storage facility with Tom Tomastik.Well not checked. Did not walk thru mature soybeans to well. New poured and sealed concrete dike. Facility looks good.
-363497075 2006-12-11 Tom Benko and I inspected this well location. There was 85 psi on the injection and 5 psi on the annulus. There was proper identification posted, however the id on the tank has deteriorated.
-399870114 2012-02-23 Inspect Well. Well incapable of production. Tubing and rods pulled and on rack.
430569968 2015-02-25 On location with UIC Inspector Tom Benko.
-462631649 2012-08-21 Inspect well with Mr. Jeff Fry, well is currently out-of-service.
-486579005 2005-02-23 Chk well and storage, Ok.
-494433907 2003-07-16 Chk well and stoarge, Ok.
-509055603 2014-10-07 Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on February 15th for 2010, 2011, 2012, and 2013.
519953143 2014-01-22 Location Information. ENTRANCE: Lat. 40.52874 Long. -82.86359 / WELL HEAD: Lat. 40.52867 Long. -82.86211 / CENTER-OF-STORAGE: Lat. 40.52884 Long. -82.86336.
-534280463 2011-11-09 Inspect well. Pressure gauge for injecting line could not be removed without stripping fitting.
554842097 2013-07-26 Davis Well Service performed rehabilitation activities on the well. M&R Investments ran a cement bond log on the well at time of purchase. A bridge plug was set at 260 and cement pumped to attempt to seal the hole that was reported to be below 200 feet from grade. Upon drill out of cement the hole was not sealed. 6/5/2012: operator was given approval to install and cement a 2-7/8 inch casing then install 1.5 inch tubing on packer for injection. 7/8/2013: it was determined that the hole in the 4.5 inch casing was between 62 and 90 feet deep. Frac sand was installed over the perforations to a depth of 2960 feet. The 2-7/8 inch liner was set at 2958.2 ft. and cement to the surface. 7/15/13: begin drilling out cement and wash out frac sand. 7/26/13: Set Parmco tension packer and 1.5 inch tubing. Circulate water and inhibitor, pressure test and pressure held for 15 minutes at 320 psi.
649728078 2004-04-14 Chk well and storage, Ok.
-690029880 2014-12-09 Inspected the Shaffer & Holzbacher #1 (SWIW #54) as part of a standard injection well status check. Inspect well, storage and identification. Status: no change in status from previous inspection.
-765298262 2008-09-03 Chk well and stroage, Ok.
772658129 2014-09-11 Inspect tank and location. Well is shut in. no change in condition. The tank has holes and has not been replaced or repaired.
-781481844 2012-05-21 Inspect Well. Outstanding Chief's order, no rehab construction activity.
92578206 2013-02-28 Attempted to contact Rusty Hudson by phone. Voice mail message was left. This well needs to be completed and put into production within 30 days of phone call otherwise the State will request the well be plugged.
-980669160 2008-03-06 Chk well and storage, Ok. Pump is running at this time. Site is snow covered.
PL9156 Preliminary Restoration done information from Data Point

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 
  2. "Ohio Department of Natural Resources RBDMS". [2]. 2015-06-19. Retrieved 2015-06-20.