Well ID: 34-035-22088
Loading map...
County: Cuyahoga
Municipality:
Operator Name: GONZOIL INC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2009-07-21
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.3389072
Longitude: -81.74185693

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2010-0 750.0 893.0
2011-0 2149.0 796.0
2012-0 1405.0 557.0
2014-0 1308.0 365.0 416.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
-1140328054 2015-05-19 I inspected this producing unit as part of routine inspection. The wellhead and battery are located in a wooded area behind a single-family home. Access to the wellhead is via the shared driveway which continues for an additional 600 feet to the wellhead. Enclosure gates are locked and secure. ID signage is present and complete. Process safety gear is present. The production tank hatches are secure. At the time of this inspection I observed the following items requiring maintenance: The electrical box is unlocked and unsecure. There is oil staining around back-pressure (Baird) valve which requires clean-up. These maintenance issues must be remedied as soon as practicable or by 06/19/2015.
1174481982 2013-09-05 The producing unit consists of a producing wellhead with pumpjack and aboveground storage tank battery. The wellhead and tank battery are enclosed in separate board-on-board enclosures. The battery is comprised of one 100-barrel production tank and one 20-barrel poly brine tank. The secondary containment is good. 1501:9-9-05E safety equipment is present. There is a separate skid-mounted compressor unit located inside a third board-on-board enclosure. Unit ID is good. I did not observe any signs of leaks or spills. There is a very large, dead, red oak (48-inch diameter, 75' in height) which is beginning to lean over the tank battery. I'm contacting Gonzoil to discuss possible intervention. The unit passes preliminary restoration.
1228129370 2013-10-28 I spoke with Doug Gonzalez about the dead tree over-hanging the battery. He indicated that they are aware and are making plans to cut the tree.
1672327703 2011-10-31 Urban Preliminary Restoration due. Preliminary Restoration passed.
-183496048 2014-03-25 The unit is producing with no observed problems. Load-outs are locked and entry gates are locked. The ID placard is good. No signs of leaks or problems. The lease road is well maintained. ID placards, secondary containment, and process safety equipment is present. Spacing is compliant. The 8.625 casing is accessible.
-2089847696 2010-02-01 checking on well site crew working on grading and planting trees.
-820711854 2009-07-22 rigging up on site.

For data sources see[2]