X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-073-22835

Well Details

Well ID: 34-073-22835
Loading map...
County: Hocking
Municipality:
Operator Name: BARCLAY PETROLEUM INC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1983-09-01
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 39.56836507
Longitude: -82.30335644

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1985-0 0.0 2318.0
1986-0 0.0 2018.0
1989-0 0.0 912.0
1990-0 0.0 930.0
1991-0 0.0 674.0
1992-0 0.0 672.0
1993-0 0.0 539.0
1994-0 0.0 457.0
1995-0 0.0 451.0
1996-0 0.0 308.0
1997-0 0.0 697.0
1998-0 0.0 532.0
1999-0 0.0 456.0
2000-0 0.0 381.0
2001-0 0.0 233.0
2002-0 0.0 0.0
2003-0 0.0 210.0
2004-0 0.0 105.0
2005-0 0.0 69.0
2006-0 0.0 126.0
2007-0 0.0 276.0
2008-0 0.0 426.0
2010-0 0.0 451.0
2011-0 0.0 433.0
2012-0 0.0 359.0
2013-0 0.0 385.0
2014-0 0.0 365.0 547.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1209696546 2006-08-17 FOLLOW UP TO NOV # -1834704169 An inspection was conducted at the facility owned by Barclay Petroleum Inc., on 8/17/2006. During the inspection, it was noted that the facility did not have identification, and C&P around the well would need to be removed. Also, noted was that the well was venting gas.
1384273402 2013-11-12 Compliance notice follow up. The well has a legible identification, the pollution and contamination has been resolved. No violations noted.
1490984849 2007-02-08 Follow-up inspection revealed that the previously noted violations have not been resolved. This case has been handed over to management. A Chiefs Order will be issued.
-1576901199 2006-10-03 Follow-up inspection revealed that the previously noted violation has not been resolved.
-1692765063 2006-11-07 A follow-up inspection conducted on 11/7/2006 revealed that violations have not been resolved. The company was contacted by telephone and informed that violations must be resolved immediately.
-1834704169 2006-08-17 An inspection was conducted at the facility owned by Barclay Petroleum Inc., on 8/17/2006. During the inspection, it was noted that the facility did not have identification, and C&P around the well would need to be removed. Also, noted was that the well was venting gas.
1853808362 2008-01-09 Lat & Long obtained for the tank battery.
PL16242 Preliminary Restoration done information from Data Point

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 
  2. "Ohio Department of Natural Resources RBDMS". [2]. 2015-06-19. Retrieved 2015-06-20.