34-153-22793

Well Details

Well ID: 34-153-22793
Loading map...
County: Summit
Municipality:
Operator Name: CARGILL INC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1994-11-05
Unconventional: No
Configuration: Vertical
Well Status: Active Injection
Violations: 0
Latitude: 41.02057448
Longitude: -81.56070852

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1104240210 2004-12-07 The 5 year MIT results are below. The reference point was tubing in the well.
    Time                  Test Pressure             Reference Pressure             Difference
    08:00                     541.300                               125.888                          415.412
    09:00                     538.863                               123.496                          415.367
    10:00                     537.633                               122.288                          415.345
    11:00                     536.406                               121.104                          415.302
    12:00                     535.054                               119.797                          415.257
    13:00                     534.143                               118.924                          415.219
    14:00                     533.267                               118.122                          415.145
    15:00                     532.640                               117.523                          415.117
    16:00                     532.065                               116.995                          415.070

The net pressure change was 0.342 psi over 8 hours for an average of 0.043 psi/hour.

1281474864 2010-08-03 Annual inspection of this solution mining well found no violations at this time. Preliminary restoration also approved.
1373215331 2013-06-24 The well was properly identified. My inspection was accompanied by Andrew Adgate.
15333265 2009-12-10 This inspection was for the five year Water-Brine Interface mechanical integrity test on the 9-5/8 production casing. The reference well for this test was the production tubing in this well. The initial pressure difference between the casing and the tubing was 424.121 psi. The final pressure difference was 424.039 psi, a change of 0.082 psi over eight readings for an average of 0.01 psi/hour. The allowable average is 0.05 psi/hour. The well PASSED the test.
1863107560 2014-12-05 A water-brine interface mechanical integrity test was performed on the well. Calculations indicated a net pressure change of less than 0.05 psi./hour, between the well and the reference. The well passed the test.
-2111959003 2003-09-08 Status check inspection - no violations at this time.
316077240 2009-06-18 Columbus requested an annual inspection of the solution mining wells. This inspection found no violations at this time.
755335926 2004-10-26 Status check inspection - no violations at this time.

For data sources see[1]