34-035-21515

Well Details

Well ID: 34-035-21515
Loading map...
County: Cuyahoga
Municipality:
Operator Name: GREEN ENERGY INC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1991-04-26
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.50419747
Longitude: -81.42613155

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1991-0 4984.0 0.0
1992-0 10236.0 0.0
1993-0 16005.0 0.0
1994-0 19846.0 65.0
1995-0 33872.0 0.0
1996-0 35324.0 144.0
1997-0 48345.0 56.0
1998-0 37508.0 0.0
1999-0 19910.0 25.0
2000-0 29515.0 0.0
2001-0 22320.0 15.0
2002-0 20341.0 0.0
2003-0 24631.0 0.0
2004-0 29216.0 0.0
2005-0 17027.0 22.0
2006-0 11826.0 0.0
2007-0 9485.0 0.0
2008-0 22454.0 36.0
2009-0 11576.0 9.0
2010-0 5603.0 0.0
2011-0 4614.0 0.0
2012-0 361.0 0.0
2013-0 2666.0 0.0
2014-0 3177.0 365.0 0.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1369344899 2013-05-23 The producing unit consists of the following elements: a wellhead with pumpjack in a chain-link enclosure, and a tank battery system also in a chain-link enclosure. The enclosures are secured with locks and in in good condition. The tank battery is comprised of two 100-barrel steel tanks, and mechanical separator. Safety equipment is needed. I did not observe any other problems or violations. I contacted Jim with Green Energy and advised him that safety equipment would be needed within the next 30 days.
1374697512 2013-07-24 The producing unit consists of a wellhead with pumpjack unit and above-ground storage tank (AST) battery. The wellhead is located in a chain-link enclosure which is locked. The well is currently producing. There is no ID at the wellhead. I did not observe any signs of leakage or problems. The AST battery is comprised of one 140-barrel production tank, one 50-barrel brine tank, and mechanical separator in a chain-link enclosure. There is a unit ID at the wellhead. Secondary containment is good. The unit is lacking safety equipment in accordance with 1501:9-9-05E. I advised Green Energy that the ID and safety gear should be adressed before the start of school year.
1385920917 2013-11-22 Safety equipment has been added in accordance with 1501:9-0-05E. No problems noted
-1595570558 2010-12-01 Site stable no off site run off.
-1800556905 2010-11-16 Company waiting on samples to be tested for disposal of gravel. All oily fluid has been removed from site. Company plans to set another 100 bbl tank in tank battery had to get approval from landowner.
2057777074 2003-09-25 inspected well and tank battery. 210bbls, seperator, plastic brine.
-2144832614 2010-11-23 Called company to check cleanup. Dike still holding fluid no oil present on fluid. Company still waiting on test results for material to go to landfill.
-329108818 2010-12-09 All contaminated soil and gravel has been removed from site and new gravel replaced and oil storage tank has been reset.

Case closed

509669623 2011-01-04 Oil contaminated soil and gravel removed from site and disposed of, new gravel replace and tanks reset.
-951029631 2010-11-10 Company called in to report a spill approximately 2 bbls of oil from oil storage tank that overflowed on Tuesday the 9th. The oil was contained inside the dike. I advised Mr.Gessle to cleanup oil remove fluids and remove gravel to landfill.

Will monitor site for final cleanup!

For data sources see[2]