34-035-21625

Well Details

Well ID: 34-035-21625
Loading map...
County: Cuyahoga
Municipality:
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2001-02-15
Unconventional: No
Configuration: Vertical
Well Status: Plugged and Abandoned
Violations: 0
Latitude: 41.55005906
Longitude: -81.45281066

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2001-0 23277.0 280.0
2002-0 33107.0 0.0
2003-0 19741.0 58.0
2004-0 7844.0 0.0
2005-0 19479.0 145.0
2006-0 13103.0 65.0
2007-0 13968.0 150.0
2008-0 13520.0 51.0
2009-0 7898.0 121.0
2010-0 8010.0 54.0
2011-0 0.0 0.0
2012-0 726.0 1.0
2013-0 0.0 37.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1175185574 2007-02-05
1240i1651286 2001-02-25 inspected site to check status drilling at 4047' utica shale getting stuck had to add mud condtioner on 02/26/2001 drilling 4551' drilling
1240i29 on site rig finished drilling td 6550' tripping out lost 8 drill collar at bottom finshed trip loggers will be at site at 2:00 pm to log hole
-1328025287 2013-01-14 The producing unit is comprised of a two-tank battery (1 210-barrel production and 1 100-barrel brine) and a wellhead with mechanical plunger lift, and mechanical separator, each in separate chain-link enclosures. The well is currently in production. The tank and well spacing is in accordance with 1509:9-9-05 . HB 278 safety equipment is present. Unit identification is present and legible at the tank battery. The tank battery secondary containment is adequate, but I observed an open pipe draining the dike. I did not observe any leaks, spills, or other signs of contamination. The gates are locked. I contacted Ralph Gregory of Bass Energy and requested that the drain be sealed with the next two weeks.
1377525095 2013-08-26 Former location of this producing unit is being restored and regraded. The wellhead was formerly located in the asphalt-paved parking area of the Philips facility. The wellhead is now sealed and covered with fill and gravel. The former tank battery has been removed and the area is regraded and seeded/
1380117337 2013-09-25 The former area of the well has been restored and seeded. I spoke with Ralph Gregory about the sales line and he indicated that a waiver has been obtained and submited by the property owner. Final restoration is complete.
-168717013 2008-04-01 no violation
-1800067142 2008-03-26 no violation
445488932 2009-04-22 No violation