34-167-26491

Well Details

Well ID: 34-167-26491
Loading map...
County: Washington
Municipality:
Operator Name: BANCEQUITY PETROLEUM CORP
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1981-03-18
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 39.58620706
Longitude: -81.65137878

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1984-0 697.0 0.0
1991-0 0.0 0.0
1992-0 926.0 0.0
1993-0 1430.0 0.0
1994-0 1494.0 0.0
1995-0 2725.0 0.0
1996-0 1265.0 0.0
1997-0 415.0 0.0
1998-0 43.0 0.0
2011-0 0.0 0.0
2012-0 0.0 0.0
2013-0 0.0 0.0
2014-0 0.0 0.0 0.0 0.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1125289912 2010-07-21 Inspection this day found tank which old oil running down side, no ID's so not sure if goes with this well but on same side of highway, all valves into tank, separator are closed, no meter found. Prior tank GPS reading may have been incorrect, but no ID's so not sure who's tank this is. At time of prior inspection in 2003, Bancequity has not turned in production so records to show well had not produced since 1998, records now confirm idle for 10+ years. Can't to well this day but not providing gas for landowner - will now write NOV. Talked to farmer and he would like something done with wells, but not issuing a complaint. Compliance Notice
1125289912 2010-07-21 Inspection this day found tank which old oil running down side, no ID's so not sure if goes with this well but on same side of highway, all valves into tank, separator are closed, no meter found. Prior tank GPS reading may have been incorrect, but no ID's so not sure who's tank this is. At time of prior inspection in 2003, Bancequity has not turned in production so records to show well had not produced since 1998, records now confirm idle for 10+ years. Can't to well this day but not providing gas for landowner - will now write NOV. Talked to farmer and he would like something done with wells, but not issuing a complaint. Compliance Notice
1489795403 2003-12-18 Inspection this day found well with pumpjack, nomotor so not capable of producing, no meter found, tank is across the highway with another tank, appears abandoned, ID's very poor, don't think well producing - this producer has numerous wells in area not producing.
-1496685786 2014-06-17 Upon inspection, it was observed that this well is incapable of production and is idle. The pumping unit is disconnected from the rods, and the electric motor is badly corroded and has no drive belt. The mechanical separator, meter run, and all associated piping are all severely corroded. No change has been made at the well location since the last inspection by Andy Thomas on 4/2/2014.
1513133079 2014-04-02 There has been no attempt to gain compliance by the company. Well is equipped with a pumping unit but has no motor. There is no bridle connecting the pumping unit to the rod string. There is a separator in the tank battery but no tanks. The dump valve on the separator is not operational. Production statements have not been submitted from 1999 to 2010. Statements from 2011 and 2012 show that the well has not produced anything. New pictures have been taken.
1601901828 2014-11-05 Upon inspection, it was observed that this well is shut in and is idle. No attempt has been made by the operator to gain compliance. I will contact Bancequity Petroleum Corp. and inform them that prompt action must be taken to bring this well into compliance in lieu of legal enforcement action.
-441159493 2010-07-21 FOLLOW UP TO NOV # -849177767 Plug or produce. Post ID's. Annual production shows well idle for 10+ years.
-554086448 2015-04-14 Upon inspection, it was observed that this well is still idle and incapable of production. The pumping unit is unbridled from the rods and is very overgrown with vegetation. The well is shut in and the associated production equipment is not fit for use. I have spoken with Mr. Tom Fischietto about this well and told him it needs to be plugged this year.
-849177767 2010-07-21 Plug or produce. Post ID's. Annual production shows well idle for 10+ years.
998399162 2014-02-04 Well is equipped with a pumping unit but has no motor. There is no bridle connecting the pumping unit to the rod string. There is a separator in the tank battery but no tanks. The dump valve on the separator is not operational.

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 
  2. "Ohio Department of Natural Resources RBDMS". [2]. 2015-06-19. Retrieved 2015-06-20.