34-035-20865

Well Details

Well ID: 34-035-20865
Loading map...
County: Cuyahoga
Municipality:
Operator Name: KLEESE DEVELOPMENT ASSOCS
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date:
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.45311971
Longitude: -81.51471172

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1996-0 2523.0 157.0
1997-0 6692.0 202.0
1998-0 4897.0 0.0
2000-0 3127.0 117.0
2001-0 3850.0 0.0
2002-0 2285.0 0.0
2003-0 2996.0 0.0
2004-0 2384.0 0.0
2005-0 1645.0 0.0
2006-0 2249.0 104.0
2007-0 1331.0 4.0
2008-0 2860.0 32.0
2009-0 2707.0 164.0
2010-0 2189.0 57.0
2012-0 1756.0 84.0
2013-0 1437.0 61.0
2014-0 1593.0 365.0 37.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
-1213228071 2013-02-19 The wellhead consists of a mechanical lift unit, not enclosed. The associated tank battery consists of 1 100-barrel (BBL) tank, 2 50 BBL tanks, and a mechanical separator, in a separate, locked enclosure. The spacing is in accordance with the rule. The tank battery dike is adequate. The unit identification is hand written and unclear. I contacted Matt Kleese and advised him about the need for revised identification. The tank battery is shared with the #2054 unit. There has been no production reports filed for this unit since 2010. I contacted Maryann at Kleese Dev. Assoc. She indicated that they may have forgotten to file the 2011 production report.
616901833 2013-08-23 The producing unit consists of the following elements: A production wellhead and aboveground storage tank (AST) battery. The production wellhead is fitted with a mechanical plunger lift system and is located 75 feet east of the tank battery. The tank battery system, which is reportedly shared with the #2 and #8, includes 1 100-barrel production tank, a 50-barrel production tank, and a 50-barrel brine tank, mechanical separator and associated appurtenances. The tank battery is overgrown with weeds. Secondary containment is adequate. Tank and well spacing is in accordance with 1501:09. The interior of the tank battery needs to be cleared of weed overgrowth. Because the tank battery is shared with multiple wells, an ID placard is needed at the wellhead. I spoke with Jim Adams, contract pumper for Kleese, about the need for ID and maintenance. He indicated that the issues would be taken care of by the end of the week.

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 